2.4 FILTRATION
2.4.1
G3845F Only
- Ensure
gas control
is in the
OFF
1
position and allow oil to cool for 15
to 20 minutes. Drain the oil into the
oil buckets
and switch on the filtration system
using the
pump switch 2.
Let the oil cycle through the provided
filtration basket
and
mesh filter
to clear the debris within the oil. The appliance is designed so that the
pump will cut-off after operating for 8 minutes. To continue with the filtration process,
simply reactivate the
pump switch
.
2.4.2 Once the oil is filtered, close the
drain valve
and activate the
pump switch
to refill the
pan. Once the oil level is between
MIN
and
MAX,
switch off the
pump switch
. After
filtering wait 30 seconds before removing the
oil bucket
.