EN
2
5
25
Activated charcoal filter (Recirculation version)
These filters are not washable and cannot be regenerated, and
must be replaced approximately every 4 months of operation, or
more frequently with heavy usage.
REPLACING THE ACTIVATED CHARCOAL FILTER
• Remove the metal grease filters
• Remove the saturated activated charcoal filter as shown (A).
• Fit the new filters (B).
• Replace the metal grease filters.
A
B
Lighting
LIGHT REPLACEMENT
40 W incandescent light.
• Remove the metal terminals fixing the light cover.
• Slide the light cover to the right until the left hand is free.
Lower it slightly and slide it to the left to free it completely.
• Unscrew the bulbs and replace them with new ones having the
same characteristics.
• Replace the lighting support in reverse order.
Lighting
LIGHT REPLACEMENT
20 W halogen light.
• Remove the 2 screws fixing the Lighting support, and pull it
out of from the Hood.
• Extract the lamp from the Support.
• Replace with another of the same type, making sure that the
two pins are properly inserted in the lamp holder socket holes.
• Replace the Support, fixing it in place with the two screws re-
moved as above.
Содержание Canopy hood
Страница 2: ...IT 2 2 Libretto di Istruzioni INDICE AVVERTENZE COMPONENTI 8 INSTALLAZIONE 10 USO 14 MANUTENZIONE 15...
Страница 3: ...EN 3 3 Instructions Manual INDEX WARNINGS COMPONENTS 17 INSTALLATION 19 USE 23 MAINTENANCE 24...
Страница 9: ...IT 9 9 Ingombro...
Страница 18: ...EN 1 8 18 Dimensions...
Страница 27: ...FR 2 7 27 Encombrement...
Страница 36: ...DE 3 6 36 Platzbedarf...
Страница 45: ...NL 4 5 45 Buitenafmetingen...
Страница 54: ...ES 5 4 54 Dimensiones...
Страница 62: ......
Страница 63: ......