INSTALLATION (EXTERNAL DUCTING)
1.
If you plan on ducting the air to the outside, your extractor can be
connected as per the picture below to a ducting pipe with an internal
diameter of 150mm.
2.
The extractor should be mounted at the following distances above the
counter top:
Above a gas hob or cooker – 75cm, but not exceeding 75cm.
Above an electrical hob or cooker – 65cm, but not exceeding
75cm.
3.
Drill 3 x 8mm holes to accommodate the mounting bracket. Screw
and tighten the bracket onto the wall with the provided screws and
plugs.
Holes on wall
Screw Plug
Wall Bracket
Screw (4mm x
30mm)