12
GB
O R I G I N A L I N S T R U C T I O N S
PRODUCT MAINTENANCE
Caution!
All maintenance works must be carried out with the water heater disconnected from the power supply. Pull the plug out
of the mains outlet.
Clean the body of the water heater and other plastic parts with a soft cloth and cleaning agents intended for the maintenance of
plastics. Chrome-plated parts should be cleaned similarly to plastics, but with suitable cleaning agents. Slightly soak the cloth in
a cleaning agent and then clean the product surface. After cleaning, wipe with a soft cloth soaked in water and then dry or allow
to dry. It is forbidden to use aggressive detergents for the product maintenance. Do not use abrasives, cleaning agents containing
alcohols, acids (except 2% solution of vinegar with water) and solvents.
The water supplying the faucet must be cleaned of any mechanical or chemical contaminants. The manufacturer does not take
responsibility for damage to the faucet caused by water contamination.
However, if the intensity of the water jet decreases, the water inlet to the faucet or the outlet from the spout may become blocked.
Caution!
Close the water supply to the heater before starting the following maintenance operations.
To clear the water inlet to the faucet, unscrew the inlet hose and carefully remove the sieve (IX).
Clean the sieve with a jet of running water and install in reverse order to disassembly. Perform a leaktightness check of the water
connections before connecting the product to the power supply.
In order to clear the outlet of water from the spout, unscrew the aerator (X) and check its patency. Check the condition of the
gasket and clean both components with a jet of running water if necessary. Then install the seal and screw in the aerator without
tools. Perform a leaktightness check of the water connections before connecting the product to the power supply.
TECHNICAL DATA
Parameter
Unit
Value
Catalog number
75921, 75922, 75923, 75924
Rated voltage
[V~]
230
Rated frequency
[Hz]
50
Rated power
[W]
3000
Degree of isolation
I
Supply water pressure
[MPa]
0,1 – 0,6
Degree of protection
IPX4
Weight:
[kg]
0,6
Diameter of the water connection
G 1/2