11
GB
O R I G I N A L I N S T R U C T I O N S
PRODUCT ASSEMBLY
Caution!
First, connect the product to the water source, check leaktightness of water connections and then connect the appliance
to the power supply. It is forbidden to assemble the product when it is connected to the power supply.
Caution!
The product is intended for vertical assembly only. Do not assemble the product in any other position.
Begin with mounting the drain spout to the water heater body. If the faucet is equipped with a manifold allowing for connection of
a hand-held shower head,
fi
rst screw the manifold onto the outlet opening of the body (II). The manifold must be screwed on so
that the water direction switch is at the front. Do not use any tools to screw the manifold on.
Before mounting the spout, check that all gaskets and the grade ring are in the cavity of the spout mounting (III). Then, not using
any tools, screw the
fi
xing ring on the water heater body thread (IV).
Properly mounted drain spout should rotate smoothly in the range of 360 degrees, with a slight noticeable resistance.
Depending on the faucet model, the body is to be mounted to the worktop or directly to the water outlet in the wall. Mount the
body of the water heater in a hole near the sink or washbasin so that water can enter the drain of the sewage system without
obstruction.
Assembly on worktop
The body mounting has a cut-out that allows for passing the power cord when the mains outlet is located under the top on which
the faucet body will be mounted. In this case, put the rubber gasket through the plug of the power cord (V). Place a rubber pad
under the body to protect the mounting space from damage. Mount the body of the water heater by screwing the
fi
xing nut under
which the spacer ring (VI) has been placed. It is recommended to tighten the
fi
xing nut without tools, but if this does not ensure a
stable mounting of the water heater body, a wrench can be used to tighten it. Be careful when tightening the nut with a wrench; it
is made of plastic and may be damaged by excessive force.
Wall assembly
The product comes with a coupling consisting of a nut, a threaded bushing with a
fl
ange and a gasket. Place a nut on the bushing
and then screw the bushing thread into the water connection thread in the wall. Seal the connection with a gasket, PTFE tape or
hemp tow. Mount the supplied gasket to the water inlet of the faucet and tighten the coupling nut to the faucet water inlet (VII). Do
not use too much force to tighten in order to avoid damaging the gasket.
Connecting to the water source
Caution!
Make sure that the water supply is closed before connecting the product to the hydraulic system.
Mount the water supply with sealing and nut to the water inlet e.g. with a
fl
exible hose (VIII).
Make sure that the water heater valve is in a closed position. When rotating the valve handle, the ratchet mechanism sounds
and the valve itself shows increased resistance during rotation. Then open the water supply to the water heater. Make sure that
the water supply does not show signs of leakage and open the water heater valve by rotating the valve to the left or right. Water
should come out of the spout outlet. Check that the connections of the spout and the body of the water heater do not show any
signs of leakage.
If any leaks are detected, close the water supply to the water heater, then remove the cause of the leaks and re-check the water
connections for leaktightness.
Once the water connections are fully tight, the heater can be connected to the power supply.
Make sure that the faucet valve is closed and no water comes out from the spout outlet, then plug the power cord plug into an
electrical outlet. Open the valve of the water heater by rotating it to the left; hot water should come out of the water outlet. At the
same time, the display on the body will show the water temperature.
For models equipped with a water jet switch, rotating the water jet clockwise as far as it will go switches the water jet to the spout
and rotating it counterclockwise as far as it will go switches the water jet to the hand-held shower head.
PRODUCT USE
Caution!
The heater can produce water at a very high temperature, which is higher than the normal hot water temperature in the
water supply system. Be careful not to burn oneself when using the water heater.
The valve opening degree regulates the intensity of the water jet. The more open the valve, the closer the lever is to the extreme
position, the more intensive water
fl
ow out of the spout outlet. However, since it is easier to heat a less intense water jet, the more
intense the jet, the lower the water temperature.
The water heater is switched on automatically after opening the water heater valve and rotating it upwards. The heater is switched
o
ff
automatically when the valve is closed. When the valve is rotated down, the heater does not start.
Caution!
In case of not using the faucet for a long period of time, disconnect it from the power supply. Pull the plug out of the
mains outlet.
Содержание 75921
Страница 55: ...I N S T R U K C J A O R Y G I N A L N A 55 ...
Страница 56: ...I N S T R U K C J A O R Y G I N A L N A 56 ...