26
USAGE
GB
E- Float Valve -
When the maximum liquid level in the
canister is reached, the float valve will automatically close
the intake aperture in the hood, interrupting the intake
process. Switch off the appliance immediately and
withdraw the mains plug.
Carry or pull the complete appliance to the disposal point
and empty the canister.
F- Water Discharge -
To empty the liquid from the tank,
turn off the motor switch and open the water discharge.
Before switching it on again verify the water discharge is
closed.
ATTENTION!
When the vacuum cleaner is working never open the
water discharge (F).
NOTE!
If foam or liquid escapes from the ventilation apertures
during cleaning operations, switch the appliance off
immediately and withdraw the mains plug. Empty die
canister and if necessary add some antt-foaming agent
Cany out a function check on the float valve before
switching on the appliance again.