MOUNTING INSTRUCTIONS
General
1. In workshops, locate heater away from sources of wood dust.
2. When heater is mounted on the wall or ceiling, provisions
must be made to bundle or otherwise prevent excess power
cord from draping loose.
Floor Application
The heater, as received, is set up for floor mounting. Place the
heater on floor or other flat surface and insert the plug into the
proper wall outlet.
The heater can be adjusted to redirect the airstream. To do this,
simply loosen the knob on either side of the heater, then pivot
heater to desired position and re-tighten both knobs.
Wall Mount
SEE WARNING NO. 12.
This heater may be mounted on any wall that will support the
weight of the heater. First remove the mounting stand from the
heater, then remove four rubber grommets from stand. Secure
stand to structural members of wall with four 1/4” dia. X 1-1/2”
long lag bolts (not provided). In masonry walls use metal expan-
sion shields or toggle bolts. Never use bolts smaller 1/4” diame-
ter.
Replace the heater in the stand and tighten knobs to lock in
place. Two large rubber washers go between heater and stand,
one on either side.
REMEMBER:
The electrical outlet must be within reach of the
six foot cord. Be sure to provide enough clearance to pivot
heater and reach adjustment knobs.
Ceiling Mount
This heater may be mounted to any ceiling that will support the
weight of the heater.
First remove the mounting stand from the heater, then remove
four rubber grommets from stand. Secure stand to structural
members of ceiling with four 1/4” diameter bolts (not provided).
In wood joist use 1-1/2” long lag bolts. In steel beams use ma-
chine bolts secured with nuts and lockwashers. Never use bolts
smaller than 1/4” diameter.
Replace the heater in the stand and tighten knobs to lock in
place. Two large rubberwashers go between heater and stand,
one on either side.
REMEMBER:
The electrical outlet must be within reach of the
six foot cord. Be sure to provide enough clearance to pivot
heater and reach adjustment knobs.
OPERATING INSTRUCTIONS:
1. To operate the heater, first select either high or low position
on the heat selector switch, then turn the thermostat knob as
far as it will go in the clockwise direction.
2. The indicator light will come on and remain on as long as the
heater is in the operating mode.
3. When the room temperature reaches the desired level, slowly
turn the thermostat knob counterclockwise until the thermo-
stat clicks.
4. To turn the heater off, turn thermostat knob as far as it will go
in the counterclockwise direction until the indicator light is off.
5. The fan selector switch allows continuous or cycling fan oper-
ation by selecting either the “ON” or “Auto” position, respec-
tively.
Note:
For summer cooling, put the unit into its Operating Mode
by turning the thermostat clockwise from its OFF position to its
lowest setting. The indicator light will come ON. Turn the fan se-
lector switch to ON position. The fan will run continuously with not
heat. If the thermosata is adjusted to demand for heat the fan will
run continuously after this demand is satisfied and the element
are turned OFF. In the AUTO position of the fan selectro switch,
the fan will come ON and OFF with the heating elements.
TO PREVENT HEATER FROM POSSIBLY FALLING, DO NOT
USE KEYHOLE SLOTS FOR CEILING MOUNT APPLICATION.
SEE ALSO WARNING NO. 13.
2
KEYHOLE
SLOT
MOUNTING
HOLES
ARE 16” O.C.
USE
KEYHOLES
FOR WALL
MOUNTING
CIRCULAR
HOLE
USE CIRCULAR
HOLES FOR CEILING
MOUNTING.
DO NOT USE KEYHOLES.
ELEMENTS FRONT
MIDDLE
REAR
HEAT SW.
HI
LOW
1
2
3
2
3
1
AUTO
FAN SW.
TERMINAL BLOCK
6
4
INDICATOR LIGHT
L1
OFF
CYL
L2
THERMOSTAT
MANUAL RESET
THERMAL LIMIT
MOTOR
ON
Figure 1
Figure 3
Figure 2