4
8055 model. VPP axes module
This module will appear in Diagnosis > Configuration > Hardware with
the name of "Axis module 2".
The axis numbering is compatible with the previous module.
Besides controlling the spindle and the axes of the machine, it governs
the first 40 digital PLC inputs and 24 digital PLC outputs. This module
offers the following features to communicate with the outside world:
Elements
Signal adapters
The following signal adapters are available to be used with the VPP
axes module.
4
Feedback inputs admitting single-ended and double-ended
(differential) TTL signals as well as single-ended 1Vpp sinewave
signals.
4
Fe e d b a ck i n p u ts a d m i t ti n g s i n g l e a n d d o u bl e - e n d e d
(differential) TTL signals.
8
Analog outputs for the servo drives.
4
Free differential analog inputs for controlling, monitoring or
supervising systems.
2
Digital probe inputs.
24
Digital outputs ,optocoupled, commanded by the PLC.
40
Digital inputs ,optocoupled, read by the PLC.
X1 - X2
X3 - X4
SUB-D HD type 15-pin female connectors for feedback systems of
each axis. They accept sinewave signals.
X5 - X6 SUB-D type 15-pin male connectors for feedback system of the axes.
Up to 2 axes may be connected per connector. They do not accept
sinewave signals.
X7
SUB-D type 15-pin male connector to connect up to 4 differential
analog inputs (range ±10V) and two probe inputs (TTL or 24V).
X8
SUB-D type 15-pin female connector to connect up to 8 analog
outputs (range ±10V).
X9
37-pin male connector of the SUB-D type for 32 digital inputs of the
PLC.
X10
SUB-D type 37-pin female connector for the 8 digital inputs of the PLC
and its 24 digital outputs.
Do not open this unit. Only personnel authorized by Fagor Automation
may open this module.
Do not handle the connectors with the unit connected to main AC
power. Before manipulating these connectors, make sure that the unit
is not connected to main AC power.
SA-TTL-TTLD
Adapter for "Non-differential TTL" to "differential
TTL" signals
SA-FS-P
Adapter for Fagor sinusoidal signal to Vpp signal.
Содержание CNC 8055
Страница 1: ...REF 0307 SOFT M 7 XX SOFT M 7 1X CNC 8055 CNC 8055i NEW FEATURES ...
Страница 2: ...Pág 2 de 2 CNC 8055 CNC 8055i NEW FEATURES SOFT M 7 XX SOFT M 7 1X ...
Страница 45: ...User notes NEW FEATURES SOFT M 7 XX Page 41 of 50 CNC 8055 CNC 8055i ...
Страница 46: ...User notes NEW FEATURES SOFT M 7 XX Page 42 of 50 CNC 8055 CNC 8055i ...
Страница 53: ...User notes NEW FEATURES SOFT M 7 1X Page 49 of 50 CNC 8055 CNC 8055i ...
Страница 54: ...User notes NEW FEATURES SOFT M 7 1X Page 50 of 50 CNC 8055 CNC 8055i ...
Страница 55: ...CNC 8055 CNC 8055 I REF 0504 SOFT M 9 0X SOFT M 9 1X NEW FEATURES Ref 0504 Soft M 9 0x Soft M 9 1x ...
Страница 56: ......
Страница 60: ......
Страница 114: ...Page 54 of 106 CNC 8055 CNC 8055i NEW FEATURES SOFT M 9 0X User notes ...
Страница 162: ...Page 102 of 106 CNC 8055 CNC 8055i NEW FEATURES SOFT M 9 1X User notes ...
Страница 165: ...Page 105 of 106 CNC 8055 CNC 8055i NEW FEATURES SOFT M 9 1X User notes ...
Страница 166: ...Page 106 of 106 CNC 8055 CNC 8055i NEW FEATURES SOFT M 9 1X User notes ...