12
5/
TROUBLESHOOTING
Fault Cause Solution
Lights on, but motor
does not work
The vent is blocked
Remove the blockage
The capacitor is damaged
Replace capacitor
The motor jammed causing
bearing damaged
Replace motor
A bad smell from the motor
which suddenly stops working
Replace motor
Light does not work,
motor does not work
Beside the above mentioned, check the following:
Light damaged
Replace lights
Power cord is loose
Connect the wires as per
the electric diagram
Oil leakage
Damper and the air ventilation
entrance are not tightly sealed
Take down the Damper and
seal with glue
Leakage from the connection of
U-shaped section and cover
Take U-shaped section
down and seal
The hood is shaking
The vent is damaged and
causes shaking
Replace the vent
The motor is not tightly attached
Lock the motor tightly
The chimney is not tightly
hanged
Attach the chimney tightly
Insufficient suction
The distance between the hood
and the gas top is too much
Readjust the distance
Too much ventilation from open
doors or windows
Choose a new place and re
assemble the machine
The machine inclines to
one side
The fixing screw not tight enough
Tighten the fixing screw
and make it horizontal
The mounting screw is not tight
enough
Tighten the mounting screw
and make it horizontal
EN
Содержание 60CFP-36IX
Страница 1: ......
Страница 2: ...2 FR EN FR ES PT 38 26 3 14 ...
Страница 4: ...4 1 NOTICES TO THE USER EN ...
Страница 14: ...14 FR 14 ...
Страница 16: ...16 1 AVIS AUX UTILISATEURS FR ...
Страница 26: ...26 ES 26 ...
Страница 28: ...28 1 AVISO A LOS USUARIOS ES ...
Страница 38: ...38 38 PT ...
Страница 40: ...40 1 AVISO PARA OS UTILIZADORES PT ...