(22/32) - DRO installation - Installation/Operation - 20i-T / 30i-T - V0612
PAR02
TTL multiplying factor (subdivision).
Independent for each axis.
Options:
x4, x2, x1 and x0.5.
The factory setting is x4 and it is the one used for FAGOR linear encoders.
When using rotary encoders on linear axes, it should be calculating according
to the number of pulses of the encoder, leadscrew pitch and the desired
resolution as per the formula:
Where:
p
= Pulses per turn of the encoder
P
= Leadscrew pitch in mm/turn
R
= Resolution in mm/pulse
F
= Multiplying factor to be applied.
PAR03
External multiplying factor
when using distance-coded reference marks or
TTL signals.
Independent for each axis. It is not required when using absolute feedback.
Options:
1, 5, 10, 20, 25, 50.
Factory setting: 1
Note:
In the table, X means that the bit is irrelevant.
p
P
RxF
----------
=
Feedback parameters
Signal
Model
PAR00
XXX
X
XXX
X
PAR01
mm
PAR02 PAR03
PAR14
TTL
MT / MKT
CT
FT
0000000X
0.005
4
X
00X0XX00
TTL dif.
MTD
MX / MKX
0.001
CX
SX
GX
FX
LX
MOX
5
00X00010
COX
SOX
GOX
FOX
25
00X01010
LOX
10
00X00110
All manuals and user guides at all-guides.com