Fagerhult e-Sense Actilume Скачать руководство пользователя страница 8

Dokumentet kan ändras utan föregående meddelande. Subject to change without notice.

Changed function after a power cut

Modes 1–5 and 8 keep the light off after power returns. Modes 
6–7 and 9–10 set the light to full. This can be changed with IRT 
9090 as follows: 

1. Press the POWER UP button once.
2. Select a new start function with the ON and OFF buttons.
3. Send the new information with a press of the green button. 

NOTE! 

Modes 1–5 switch off after a power cut. The system 

requires at least a 15 second reset period before the light can 
be switched on using the proximity sensor.

Mode

Range of use        

Function after 

power cut

1

Office room

Switched off

2

Open-plan offices

Switched off

3

  School/classroom min.

  Switched off

4

  Office landscape according to EN 12464

Switched off

5

Office room according to EN 12464

Switched off

6

Corridor

On

7

Toilet

On

8

Meeting room/conference room with light 

scenarios

Switched off

9

Office landscape 

(requires switching off centrally with 230 V)

On

10

Office landscape according to EN 12464 

(requires switching off centrally with 230 V)

On

Change level before switching off

The low level (background) before switching off, available in mo-
des 2, 6 and 9, is preprogrammed to 20 %. In modes 4, 7 and 10, 
the level only applies to DALI 2 and is selected to 100 %. The level 
can be changed as follows for all these modes. 

1. Press the BACKGROUND button once.
2. Select a new light level for 10, 20, 30, 40, 50, 60 or 70%. The 
minimum level is selected with the 0 button.
3. Send the new information with a press of the green button.

Mode

Range of use

Low level %

1

Office room

-

2

Open-plan offices

20 %

3

  School/classroom min.

-

4

  Office landscape according to EN 12464

100 %

5

Office room according to EN 12464

0

6

Corridor

20 %

7

Toilet

100 %

8

Meeting room/conference room with light 

scenarios

-

9

Office landscape 

(requires switching off centrally with 230 V)

20 %

10

Office landscape according to EN 12464 

(requires switching off centrally with 230 V)

100 %

8

Содержание e-Sense Actilume

Страница 1: ...ing installation directive EN 12464 These additional modes are easily programmable with a push of the IRT 9090 00 IR transmitter The Actilume system always switches to the maximum light level before daylight adjustment begins Deployment with service button on the sensor Startup Requirement Fixture correctly positioned e g over the work space Power up the fixture The light will switch on after appr...

Страница 2: ...ts to daylight Mode 1 one flash Office room Mode 2 two flashes Open plan office solution 1a The light is switched on when the proximity sensor is trig gered if the light level is too low Daylight adjustment active 1b The light is switched off when the proximity sensor is triggered if the light level is sufficient The light is switched on when daylight adjustment is active if the level drops below ...

Страница 3: ...ex or the light level is wrong relative to the amount of daylight See illustration below Example Classroom A normal classroom has a large window area along one of the long walls The lighting closest to the window is connected to DALI 1 Window and is adjusted from 3 100 The fixtures in the centre and further inside the space are adjusted with an offset of 30 which compensates for the lower level of...

Страница 4: ...measure ment The desired setpoint must be set with no interference from daylight Small sharp reflections from glass objects for example may affect the total value The sensor should be pla ced so that it reads the work surface in a workspace An ideal position would be directly above the centre of the desk but if the sensor is integrated into the end of a fixture it should be directed away from the ...

Страница 5: ...0 0 Switched off Daylight adjustment workspace light only 6 Corridor Corridor Auto on off 15 60 min 20 On 7 Toilet Washbasin Toilet Auto till från 15 15 min toilets only 100 On Daylight adjustment washbasin only 8 Meeting room conference room with light scenarios Channel 1 Channel 2 Manual on Auto off 15 0 Switched off No daylight adjustment 9 Office landscape requires switching off centrally with...

Страница 6: ...th 230 V Programming a preset mode 1 Press button MODE 2 Select a MODE from 1 to 10 3 Send the new information with a press of the green button Aim carefully at the IR receiver the sender has a very narrow beam to prevent accidental transmission to nearby systems The light will flash once to confirm the new setting Setting daylight level With the IRT 8099 IR transmitter Fagerhult order no 86155 it...

Страница 7: ...mall movements 1 Press the TEST button once The light will adjust downwards First check that there are no people under the sensor Walk slowly towards the zone until the light flashes Reset the fun ction by pressing the TEST button again To check the mode that has been programmed e Sense Acti lume can indicate the mode that is selected 1 Press the MODE button once The light is first adjusted downwa...

Страница 8: ... room with light scenarios Switched off 9 Office landscape requires switching off centrally with 230 V On 10 Office landscape according to EN 12464 requires switching off centrally with 230 V On Change level before switching off The low level background before switching off available in mo des 2 6 and 9 is preprogrammed to 20 In modes 4 7 and 10 the level only applies to DALI 2 and is selected to ...

Страница 9: ...o install deploy and use NOTE Important Philips has updated the Actilume system and has added functions for Philips OccuSwitch DALI also This means that the programming tool IRT 8099 00 has been replaced with IRT 9090 00 with effect from 2014 All the original program ming functions are the same but the new functions cannot be programmed into Actilume generation 1 which Fagerhult uses in all its fi...

Отзывы: