Variable LPG Installation Kit
Page 3/5
(3)
Push the float (6) on the installation tube (5) and reinstall the adjusting ring (7) at
the lower end of the installation tube.
Make sure that the adjusting ring (7) is fixed.
Make sure that the float (6) points with the TOP mark towards the flange (8).
ELECTROSTATIC HAZARD: When using a plastic float in potentially explosive
areas, it must be ensured during installation, operation and maintenance work
that the float cannot ignite due to friction or electrostatic charge.
(4)
Insert the installation tube
in the tank opening and
fix the flange onto the
tank (red arrows).
Make sure that the installation tube is still movable (white arrow).
(5)
Carefully push down the installation tube until it touches the bottom of the tank.
(7)
(6)
(5)
(8)
TANK