background image

 

Variable LPG Installation Kit  

Page 1/5 

1

 

Design 

The Variable LPG Installation Kit has been developed for FAFNIR sensors to measure the 

level in LPG tanks without having to mount the sensor in the tank. Instead, an installation 

tube is installed in the tank to hold the sensor for level measurement. The sensor can 

therefore be inserted or removed from the the installation tube at any time without having 

to open the tank. 
The Variable LPG Installation Kit consists of an installation tube with LPG float (BUNA), a 

compression/cutting ring fitting (non-detachable) with ¾" NPT external thread for process 

connection, and a reducer with a PTFE compression fitting (detachable) for fixing the 

measuring sensor (VISY-Stick LPG sensor), see figure below: 
 

 

Clamping ring  

(PTFE) 

Clamping ring  

(stainless steel) 

Reducer  

 16 /

 12 

Detachable PTFE clamping ring 

fitting for attaching the  

VISY-Stick LPG sensor 

ap

pr

. 5

Ins

tal

lati

on 

le

ng

th adj

us

ta

bl

Ins

tal

lati

on 

tu

be

 le

ngt

h (

can 

be

 c

ut 

on s

ite

Installation tube  

 16 x 1.5 

Dimensions in mm 

Compression/cutting 

ring fitting, stainless steel  

non-detachable 
¾" NPT external thread 
 
 
 
 
 
Installation tube 

can be cut on site 
 
 
 
 
 
 
Marking "TOP" 
 
 
Float Ø 40 x 120 

(Material: BUNA) 

 
 

Adjusting ring 

ap

pr

. 3

Process connection, customer site 

 - not supplied by FAFNIR -

  

¾" NPT thread, centred 

e.g.: Flange, DN 50, PN 40, form C 

ap

pr

. 2

Содержание 350094

Страница 1: ...ical Documentation FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Germany T 49 40 39 82 07 0 Web www fafnir com Variable LPG Installation Kit Installation guide 350094 4 2023 10 Art No Version Edi...

Страница 2: ...hortening the Installation Tube optional 4 3 3 Fixing the measuring sensor VISY Stick LPG 5 4 Offset settings with VISY Setup 5 Copyright Reproduction and translation are permitted solely with the wri...

Страница 3: ...chable with NPT external thread for process connection and a reducer with a PTFE compression fitting detachable for fixing the measuring sensor VISY Stick LPG sensor see figure below Clamping ring PTF...

Страница 4: ...ded in FAFNIR s scope of supply Pipe cutter for stainless steel if needed to shorten the installation tube not included in FAFNIR s scope of supply 3 Installation 3 1 Assembly of the Installation Tube...

Страница 5: ...8 ELECTROSTATIC HAZARD When using a plastic float in potentially explosive areas it must be ensured during installation operation and maintenance work that the float cannot ignite due to friction or e...

Страница 6: ...of the cutting ring fitting at the 2nd Marking hand tight first 9 Hold the fitting body and fix the cutting ring fitting with a 1 clockwise turn of the union nut After the fixing the cutting ring fit...

Страница 7: ...d remove any dirt particles from the tube 4 Push the PTFE compression fitting 3 back on and fix the fitting body 3a with the union nut 3b to the installation tube 3 3 Fixing the measuring sensor VISY...

Страница 8: ...FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Germany T 49 40 39 82 07 0 E mail info fafnir com Web www fafnir com...