Variable LPG Installation Kit
Page 5/5
Observe the following Safety Mounting Instructions:
- When shortening, only use pipe cutters for stainless steel.
- Make sure that no dirt particles get into the installation tube.
- Protect the installation tube against bending.
(1)
Remove the PTFE compression fitting (3) from the top of the installation tube (5).
(2)
Shorten the installation tube to the desired length.
(3)
Deburr, clean and remove any dirt particles from the tube.
(4)
Push the PTFE compression fitting (3) back on and fix the fitting body (3a) with the
union nut (3b) to the installation tube.
3.3
Fixing
the measuring sensor (VISY-Stick LPG)
Carefully push the sensor into the compression fitting (3) on the installation tube (5) until it
lightly touches the ground. Fix the sensor with the PTFE screw connection (3c).
4
Offset settings with VISY-Setup
For the VISY-X tank level measurement, an offset of 18 mm (safety distance 10 mm +
bottom of installation tube 8 mm) must be entered in VISY-Setup and LPG selected as the
product quality.
(3)
(3a)
(3c)
(3b)
(5)
(5)