MALFUN.
CODE
053
054
055
058
059
066
067
098
SOLUTIONS
POSSIBLE CAUSES
DESCRIPTION
Steam
thermocouple
(Turbosteam)
Value is outside of acceptable range
KTY plugs (group)
Value is outside of acceptable range
KTY plugs (group)
Timeout plug resistance activation
Boiler overpressure alarm
(only for machines with a pressure
sensor)
Boiler:
Refill timeout
Failure to read impulses by
volumetric meter of turbine
during coffee dispensing
Failure to read impulses by
volumetric meter of turbine
during circuit wash cycle
Historical malfunctions and
wash 1 reset
• Disconnected
thermocouple
• Malfunctioning card
• Disconnected KTY
• Malfunctioning card
• Disconnected KTY
• Malfunctioning card
• No water
• Refill EV failure
• Wiring interrupted
• Card failure
• No water
• Broken pump
• Too much coffee
• Coffee ground too fine
• Clogged filters
• Coffee solenoid valve
clogged or defective
• Broken turbine
• No water
• Broken pump
• Clogged filters
• Coffee solenoid valve
clogged or defective
• Broken turbine
• Breakdown log initialization.
Open the machine
-
Check cabling
-
Replace the thermocouple
-
Replace the card
Open the machine
-
Check cabling
-
Replace the KTY
-
Replace the card
Open the machine
-
Check cabling
-
Replace the KTY
-
Replace the card
• Check cabling
1
Open the machine
2
Use test panel to check if the counter function works
during coffee dispensing
-
If the counter works only with a few impulses:
- Check the granulometry and quality of the ground coffee
- Clean the filters
- Check if the coffee solenoid valve and coffee hydraulic
circuit are clogged
-
If the counter does NOT function:
- Check if there is water and if the pump works
- Replace the turbine
- Check the cabling
1
Open the machine
2
Use test panel to check if the counter function works
during the wash cycle
-
If the counter works only with a few impulses
- Clean the filters
- Check if the coffee solenoid valve and coffee hydraulic
circuit are clogged
-
If the counter does NOT function:
- Check if there is water and if the pump works
- Replace the turbine
- Check the cabling
18. Defects - Malfunctions
Содержание X2 GRANDITALIA
Страница 4: ...X2 GRANDITALIA 6 3 12 16 6a 13 14 15 17 23 35 39 18 1 26 5...
Страница 5: ...X2 GRANDITALIA CK 6 3 12 16 6a 13 14 15 17 23 35 39 18 1 26 5 Chc...
Страница 24: ......
Страница 38: ...English English...
Страница 46: ...English English...
Страница 51: ...English English 1 Description of the machine X2 GRANDITALIA 3 5 6 12 15 14 17 16 23 13 35 1 39 18 6a...
Страница 53: ...English English...
Страница 71: ...English English...
Страница 89: ...English English...
Страница 95: ...English English FC3 1 17 Weighting Weighting phase Standby...