Retractable Oil-hydraulic Bollard

English

!

!

!

!

Meccanica Fadini is not liable for any possible damages derived from incorrect use or from any use not 
indicated in this manual, furthermore it is not answerable for malfunctioning caused by the use of 
materials or accessories not approved by the company itself.
It is to be noted that the product respects the impact and breakout resistance values as indicated provided 
that the installation of the same is carried out in observance of the specifications included in this manual of 
instructions. Various factors are to be carefully taken into consideration such as compaction index, soil 
permeability coefficient, concrete type, which may affect the indicated values even significantly.

This symbol indicates that a particular attention is required on the installation phases and on running the 
operator. Failure to observe these indications may cause incorrect functioning of the bollard.

INFORMATION ABOUT SAFETY AND PROPER FUNCTIONING OF THE SYSTEM

1) Installation operations, testing, analysis of the risks and future maintenance are to be executed by qualified and authorized 
technicians in compliance with the existing regulations (www.fadini.net/supporto/download)
2) This automatic system is intended to be exclusively used for the applications described in this manual, including all of the 
safety and command accessories, at least as required.
3) Any application not indicated in this manual may cause malfunctioning or damages to people and properties.
4) Make sure the soil is adequate to take the bollard to avoid that settling at a later stage causes problems to the system 
5) Make sure the site is free from utilities that may interfere with it.
6) Make sure that electromagnetic sources are at a suitable distance from the accessories, especially from the loop detectors. 
The magnetic fields of other sources might affect the detections of the safety loops as well as those of the other command 
and safety devices of the system.
7) Make sure the power supply to the electric motor is 230 V (50 Hz).
8) 

It is recommended either of the following power supply cables:

- cable type BUT FLESSIBILE FG 7OR 12x1,5 mm² (up to 50 m maximum): for the TALOS bollard in the standard version, 
   without optional accessories;
- cable type BUT FLESSIBILE FG 7OR 12x1,5 mm² (up to 50 m maximum): for the TALOS bollard in the version fitted with
   one optional accessory maximum (either solenoid valve, obstacle detector or heater);
- cable type BUT FLESSIBILE FG 7OR 16x1,5 mm² (up to 50 m maximum): for the TALOS bollard in the version fitted with
   two or all of the three optional accessories (solenoid valve, obstacle detector and heater);
N.W. The presence or not of the beeper on the TALOS bollard, does not affect the cable choice.
The section of the ground cable is to be chosen in compliance with the requirements of the installation site.

9) In case any components or accessories need replacing, use only original parts as provided by the manufacturer.
10) The installer shall provide the final user with information related to all of the operating commands and functions of the 
system, including that concerning lowering of the post in case of an emergency (manual release operation).
11) The installer shall inform the final user of the dangers coming from the presence of persons, especially children, in the 
proximity of the bollard. 
12) The manufacturer reserves the right to change this manual without previous notice.

As far as configuration and execution of the system are concerned, these are to comply with the laws in the country of 
installation.

18

Содержание TALOS Series

Страница 1: ...BOLLARD WITH RETRACTABLE CYLINDRICAL POST OIL HYDRAULICALLY OPERATED GB Instructions manual pages the gate opener 1 20 EN 13241 EN 12453 EN 12445...

Страница 2: ...e safety accessories such as photocells sensitive edges etc Carry out a risk analysis by means of appropriate instruments measuring the crushing and impact force of the main opening and closing edge i...

Страница 3: ...an area The TALOS series includes a vast selection of options as indicated below varying in height thickness and depth of embedding constraint for impact resistance the abbreviation HRC identifies th...

Страница 4: ...triangular socket end Post cover with rubber edge n 9 Led lights flashing amber in colour Back reflecting sticker with logo Box to house the electric cable from the electronic controller Cover plate C...

Страница 5: ...supply cable 9 Post for Fit 55 photocell projector 10 Oil hydraulic bollard Talos series 11 Vix 53 remote control transmitter 12 Post for Fit 55 photocell receiver 13 Visual 344 post to take command a...

Страница 6: ...own into the pre holed seats NOTE WELL make sure the ground cable is disconnected from the casing before lifting Carefully hoist and remove the inner assembly of the bollard by a winch Make sure the c...

Страница 7: ...ead the electric cables through it from a junction box or directly from the electronic controller Elpro S40 Pic 6 NOTE WELL the foundation casing is to be set perfectly levelled and the upper edge mus...

Страница 8: ...r than the surrounding walking surface in order to limit the amount of water that may get inside it Cast concrete all around the casing up to 5 10 cm from walking level Wait all the time required for...

Страница 9: ...al see catalogue Pre assembled loop 12 metres circumference optional see catalogue Power supply cable max 10 metres pre fitted to the loops Detector for metallic masses See the instructions supplied w...

Страница 10: ...allation as required either for public or private users and in compliance with the existing safety norms A screw is provided for proper connection For applications in public areas use a cable having a...

Страница 11: ...B of the Elpro S40 controller unless required to achieve a good performance of the bollard For the Talos option 12 mm thickness a 20 F capacitor is required to be added to the terminals A and B of El...

Страница 12: ...he electric power is supplied check the status of the LEDs first of all as follows with the post in down posistion the L8 LED must be OFF while L9 must be ON if not swap the connections to terminals 1...

Страница 13: ...nce of the bollard For the Talos option 12 mm thickness a 20 F capacitor is required to be added to the terminals A and B of Elpro S40 common common connections to the electric motor of the hydraulic...

Страница 14: ...HE POST BE ASSISTED TO REACH THE FULLY FLAT DOWN POSITION Retractable Oil hydraulic Bollard English Pic 21 Pressure switch adjustment 1 Unscrew the M5 pin 2 Adjust the sensitivity using an allen key s...

Страница 15: ...pment to release the unit and allow manual lowering ATTENTION once the post has been manually lowered rising can be made possible only by powering the system and pulsing it to rise Pic 23 Help the pos...

Страница 16: ...tion date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation maintenance repairs and replacements to be mad...

Страница 17: ...ic board controlling the bollard s e g flooded relay contacts oxidized terminal clamps etc Check the correct functioning and positioning of the limit switches Check the release system for bollard manu...

Страница 18: ...interfere with it 6 Make sure that electromagnetic sources are at a suitable distance from the accessories especially from the loop detectors The magnetic fields of other sources might affect the dete...

Страница 19: ...ion impact resistance 90 000 J breakout resistance 550 000 J Static load max 1 500 kg in standing position max 20 000 kg in lowered position Working temperature 40 C 80 C Supply voltage 230 Vac 10 50...

Страница 20: ...out 12 Vdc 600mA LED lights 12 Vdc Post material S235JRH 4 mm steel S355J2H 12 mm steel AISI 304 inox AISI 316 inox brushed SS steel standard HRC Impact resistance thick 4 52 000 J 70 000 J Crash resi...