manualshive.com logo in svg
background image

Pic. 12

En

g

lis

h

MEC 200 LB 
Reversible

Chain

Chain tensioner

Door

stop in open

position

Door
stop in open
position

Driving pin

Upper

chain

Lower

chain

Chain and 

fastening system 

cover

Fastening 
of the left

door

Fastening  

of the right

door

Electric lock 
mounted on post

Door to move this 

way to close

Electric lock

mounted on a post

Lock catcher fixed

on to the door

VIEW FROM INSIDE

Door fastened
to the chain

APPLICATION OF  MEC 200 LB REVERSIBLE

MEC 200 LB

10

Chain-drive electromechanical operator 

for sectional, folding and industrial doors

Содержание MEC 200 LB

Страница 1: ...EN 13241 EN 12453 EN 12445 MEC 200 LB Chain drive electromechanical operator for sectional folding and industrial doors 1 12 GB instructions manual pages the gate opener...

Страница 2: ...he gate warning about the presence of an automated installation The installer must inform and instruct the end user about the proper use of the system by releasing him a technical dossier including la...

Страница 3: ...t is strong and reliable The torque control is by mechanical clutch system adjustable by hand Worm and gear coupling made of steel and bronze mounted on bearings all parts in an oil bath The manual re...

Страница 4: ...7 Fit 55 photocell receiver 8 Cable release lever optional 9 MEC 200 LB 10 Miri 4 flasher with incorporated aerial 11 Elpro 37 electronic control box and VIX 53 2 R plug in radio receiver card 12 230...

Страница 5: ...unlock the tensioner pinion Adjust the position of the pinion as required by screwing or unscrewing the hexagonal head positioned on the side Once satisfied the pinion is in the correct position for t...

Страница 6: ...ble by metallic cable whose device can be positioned within easy reach on the wall optional on request or by a lever with a ring at the end to be pulled by a hook not included in the equipment English...

Страница 7: ...manual release move the contact shaft halfway the travel manually move the door to the closed position on to the door stop or very close to it by a screwdriver onto the dedicated adjusting screw drive...

Страница 8: ...ternal limit switches recommended for doors wider than 8 meters does not require any adjustment the open and close limit switches are to be positioned in a way they correspond to the actual open and c...

Страница 9: ...No 2036L 3 1 2 chain item code No 2054L 4 Fixing plate item code No 2046L 5 MEC 200 LB item code No 2051L 6 Cable release item code No 2044L 7 Lateral running tracks 8 Sectional door APPLICATION OF M...

Страница 10: ...ystem cover Fastening of the left door Fastening of the right door Electric lock mounted on post Door to move this way to close Electric lock mounted on a post Lock catcher fixed on to the door VIEW F...

Страница 11: ...barrier Operator model Dimensions per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary s...

Страница 12: ...speed Capacitor Intermittent service Single phase 0 37 kW 0 5 HP 230 Vac 510 W 2 4 A 20 F Three phase 0 37 kW 0 5 CV 230 400 Vac 575 W 2 1 1 2 A Single phase 0 73 kW 1 0 CV 230 Vac 50 Hz 1 130 W 5 7...