page 9
!
M1
L
UNL
ON
OFF
1
2
3 4 5
6 7
8 9 10 11 12
DIP-SWITCH - A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
NC
common
NEUTR
A
L
26
27
28
+
_
Power supply
24V - 50mA max.
230V
400V
ON
OFF
1
2
3 4
DIP-SWITCH - B
ELPRO 37 DS
UNL
E 37
L0
L1
L4 L5 L6 L7 L8
L10
-
+
-
+
-
+
-
+
T.FUN
L33 L34
32 33 34
8,2 k
Ω
or NC
common
JA
1 2
SETUP
EDGE
TYPE
JB
1 2
L.sw.O.1
L.sw.C.1
common
8,2 k
Ω or
NC
1
2
4
5
3
16
17
18
19 20
21
22
23
38
39
F6=2A protection
24V
LI
V
E
LI
V
E
30 31
L.sw.C.2
LIMIT SWITCH
M2
LIMIT SWITCH
M1
L30 L31
ELECTRIC MOTOR
Power supply
M2
common
Capacitor for
single-phase motors
42
43
44
!
ATTENTION: Remove the
connector of single phase
power supply
CONNECTION OF A SECOND
ELECTRIC MOTOR
SINGLE – THREE PHASE ELECTRONIC CONTROL BOARD WITH ELECTRONIC BRAKE FOR
DOUBLE-LEAF SLIDING GATE AUTOMATIC SYSTEMS WITH OR WITHOUT LIMIT SWITCHES
ATTENTION: Before starting the electrical connections, check the voltage (230V or 400V) selector switch to be
set correctly.
In cases a motor with mechanical brake is used or a control board ELPRO 14 is replaced, the DIP-switch-A
No.12 has to be in OFF.
SAFETY EDGE
in CLOSING
SAFETY EDGE
in OPENING
L
.s
w
.O
.2
RUN
TIME
0s - 120s
DWELL
TIME
1s - 220s
PEDESTRIAN
1s - 45s
ELECTRONIC BR
A
KE
INTENSIT
Y
F4=2A transformer and
electronic brake
protection
PLUG-IN
RADIO
CARD
CONNECTOR
CARD
CONNECTOR FOR
TRAFFIC LIGHTS
(Item 7282L)
F3=16
A
net
w
ork
F2=16
A
net
w
ork
F1=16
A
net
w
ork
F5=630
A
flashing
light protection
24V AC output
for photocell TX
enabling
DSA control
LI
V
E
LI
V
E
230Vac
OUTPUT for
flashing lamp
max 25W
ELECTRIC MOTOR
power supply
Capacitor for
single-phase motors
Single-phase control board
power supply
230V - 50/60Hz ±10%
Three-phase control board
power supply
400V - 50/60Hz ±10%
photocell
in closing
radio contact
common
open
close
stop
Indication lamp 24
V
ma
x 3
W
24
V
ac output
(ma
x load:
n°1 radio recei
v
er
n°3 pairs photocells
po
w
er suppl
y for
electric lock 15
V
A
ma
x
or indication lamp
pedestrian
General description:
the electronic control box ELPRO 37 DS has been developed to provide a reliable unit to control double-leaf sliding gate automatic
systems with or without electronic brake and limit switches. Single-phase 230V 50/60Hz or Three-phase 400V 50/60Hz ELPRO 37 DS complies with the Low
voltage norms 2006/95 CE and electro-magnetic compatibility 2004/108/CE. Installation is recommended by qualified technical installation agents in
compliance with the existing regulations. The manufacturer is not liable for any incorrect use of this appliance; and also reserves the right to change and
update it without previous notice.
NOTE:
The green LEDs must
always be on.
IN CASE OF FAILURE PLEASE MAKE SURE THAT:
- Power supply to the electronic control board is 230V ±10% or 400V ±10%
- Power supply to the electric motor is 230V ±10% or 400V ±10%
- All of the fuses is all right
- The photocell contacts are closed
- No voltage drop has occurred from the Elpro board to the electric motor
- All of the NC contacts of the control board are all right.
- The limit switches are properly connected and work correctly
IMPORTANT FOR THE INSTALLATION AND THE CORRECT FUNCTIONING:
- The control box must be installed in a dry and sheltered place; suitable holes are provided with the FADINI universal box for fitting purpose and in
case any commercial box is used, this must be adequate to the job
- Make sure that power supply to the control board be
230V ±10% or 400V ±10%
- Make sure that power supply to the electric motor be
230V ±10% or 400V ±10%
- For distances longer than 50 metres increase the section of the wires
- Fit the mains to the control box with a high sensitivity, 0.03A, differential, magnetic-thermal circuit breaker
- Cables with 1.5mm² section wires are to be used for the power supply, electric motor and flasher for distances up to 50 m
- Cables with 1mm² section wires are to be used for the limit switches, photocells, push buttons and accessories
- If no photocells are used link out terminals 1 and 2
- If no stop button is used link out terminals 3 and 6
- Open/close motor run time trimmer must be always superior to the time actually required for the gate travel
N.W.: For applications such as light switching, CCTV, etc. use solid state relays to prevent the microprocessor from being affected
Diagnostic LEDs:
L ON =
Board on 230V or 400 V voltage and F1, F2, F3, F4, F5, F6 fuses all right
L0 OFF =
Pedestrian mode, it switches on by any pedestrian pulse
L1 ON =
Pair photocells in closing not obstructed
L4 OFF =
Open, it switches on by any open pulse
L5 OFF =
Close, it switches on by any close pulse
L6 ON =
Stop, it switches off by any stop pulse
L7 OFF =
Radio, it switches on by any pulse from the transmitter/radio contact
L8 ON =
It switches off when Fc.C. (limit switch closing = L-sw.C) is engaged, M1
L10 ON =
It switches off when Fc.A. (limit switch opening = L-sw.O) is engaged, M1
L30 ON =
It switches off when Fc.A. (limit switch opening = L-sw.O) is engaged, M2
L31 ON =
It switches off when Fc.C. (limit switch closing = L-sw.C) is engaged, M2
L33 ON =
Safety edge protecting closing not obstructed
L34 ON =
Safety edge or photocell protecting opening not obstructed
Symbols
NC
contact
NO
contact
Led
ON
Led
OFF
Pilot light
Flasher
Resistive contact
8,2 k
Ω
or NC
meccanica
FADINI
GB
37
DS
EARTH CONNECTION