page 10
Limit switch:
8 9 10
common
32
common
30 31
L-sw.O.2
L-sw.C.2
LIMIT SWITCH
MOTOR 2
LIMIT SWITCH
MOTOR 1
L-sw.O.1
L-sw.C.1
L-sw.C.
= Limit switch closing
L-sw.O.
= Limit switch opening
Key-switch:
Photocells in
closing:
1
DIP-SWITCH-A N° 1:
ON:
stop gate/s in opening and reverse
travel in closing when cleared
OFF:
no stop in opening and reverse travel in
closing when obstructed
Radio contact
(step by step mode):
Any NO connection to these two terminals
will perform the following:
- Opening only:
Dip 2=ON and Dip 5=OFF
- Gate travel reversing by any pulse
Dip 2=OFF and Dip 5=OFF
- Step by step: Open-Stop-Close-Stop
Dip 2=OFF and Dip 5=ON
- No new pulse is accepted in opening. In
Dwell phase and in closing any new pulse
stops and reverses gate travel:
Dip 2=ON and Dip 5=ON
ON:
it does not stop and reverse gate travel
in opening
OFF:
always stops & reverses in opening
2
ON:
step by step with intermediate stop
OFF:
gate travel reversed by any radio pulse
5
DIP-SWITCH-A N°2 and N°5:
All NC contacts of safety
accessories such as
Photocells (receivers)
must be connected in
series with terminals
1 and 2
Accessory
Electrical connections
NO and NC contacts to be connected
to the respective terminals in the key-
or button-switches.
All of the possible setting combinations
are described in the instructions sheets
included with the respective control
accessories
NC
NC
1 2
3 4 5 6
F A
D
I N
I
F A
D
I N
I
NC
OPEN
CLOSE
S
T
OP
COMMON
RADIO
CONTACT
COMMON
3
7
L1 ON
=
no obstacle, it goes off
in case of obstruction
L4 OFF =
no OPENING contact, it goes on
whenever an opening pulse is given
L5 OFF =
no CLOSING contact, it goes on
whenever a closing pulse is given
L6 ON =
STOP contact closed, it goes
off whenever a stop pulse is given
L7 OFF =
no RADIO contact, it goes on by
any radio pulse
Dip-Switch A
1 = ON
Photocells stop gate in opening
2 = ON
Radio, no reversing in opening
3 = ON
Automatic closing
4 = ON
Pre-flashing enabled
5 = ON
Radio step-by-step
6 = ON
Dead man
ON
OFF
1
2
3 4 5
6 7
8 9 10 11 12
DIP-SWITCH - A
7 = ON
Flasher off in dwell time in automatic
8 = ON
Gate re-closing in opening and dwell on photocells engaging
9 =
ON
DSA control of photocells before any movement
10 = ON
Photocells not obstructed before moving
11 = Blank
12 = ON
Electronic brake enabled
Dip-Switch B
1 = ON
set braking duration
2 = ON
set additional stop time after braking when safety devices are activated
3 = ON
set electric lock or courtesy lamp duration
4 = OFF
Blank
1
2
3 4
ON
OFF
DIP-SWITCH - B
F A
D
I N
I
Dip-switch setting and LED indication of functions
Output for a 24V max 3W indication lamp
showing the status of the system:
Lamp
ON
= gate open
Lamp
OFF
= gate closed
0.5s (fast)
flashing = gate closing
1s (normal)
flashing = gate opening
Indication lamp
output
24V- max 3W:
COMMON
3
11
12 13
24Vac output
max. load:
n°1 radio receiver
n°3 pairs photocells
FA
DINI
1
2
3
4
5
6
7
8
9
A
B
S
TOP
!
ATTENTION: Before starting the electrical connections, check the voltage (230V or 400V) selector switch to be
set correctly.
In cases a motor with mechanical brake is used or a control board ELPRO 14 is replaced, the DIP-switch-A
No.12 has to be in OFF.
L8 ON =
OFF on engaging L.sw. closing M1
L10 ON =
OFF on engaging L.sw. opening M1
L30 ON =
OFF on engaging L.sw. opening M2
L31 ON =
OFF on engaging L.sw. closing M2
IMPORTANT:
if
no limit switches
are involved,
link out limit switches terminals.
Limit switches ( L-sw.) must have normally closed contacts.
SINGLE – THREE PHASE ELECTRONIC CONTROL BOARD WITH ELECTRONIC BRAKE FOR
DOUBLE-LEAF SLIDING GATE AUTOMATIC SYSTEMS WITH OR WITHOUT LIMIT SWITCHES
meccanica
FADINI
GB
37