1 2 3 4 5 6 7 8 9 10 11 12
ON
DIP-SWITCH - A
OFF
1
2 3 4
DIP-SWITCH - B
ON
OFF
2
5
DIP-SWITCH - A N° 1:
1
Photocells in closing:
Limit switch:
IMPORTANT:
if
no limit switches are involved
, link out limit
switches terminals. Limit switches (L-sw.) must have normally
closed contacts
1
3
3
7
4 5 6
12 13
2
NC
NC
NC
3
11
L8 ON
= OFF on engaging L-sw. closing M1
L10 ON
= OFF on engaging L-sw. opening M1
L30 ON
= OFF on engaging L-sw. closing M2
L31 ON
= OFF on engaging L-sw. opening M2
12
ATTENTION:
before starting the electrical connections, check the voltage (230 V or 400 V) selector switch to be set correctly.
In cases a motor with mechanical brake is used or a control board ELPRO 14 is replaced, the DIP-switch-A No.12 has to be in OFF.
!
LIMIT SWITCH
MOTOR 1
LIMIT SWITCH
MOTOR 2
8 9 10
30 31 32
L-
sw
.C.1
L-
sw
.C.2
L-
sw
.O
.2
L-
sw
.O
.1
common
common
Elpro 37 DS
L-sw.C. = Limit switch closing
L-sw.O. = Limit switch opening
SINGLE - THREE PHASE ELECTRONIC CONTROL BOARD
WITH ELECTRONIC BRAKE FOR DOUBLE-LEAF SLIDING GATE
AUTOMATIC SYSTEMS WITH OR WITHOUT LIMIT SWITCHES
GB
Dip-switch A
1 = ON
Photocells stop gate in opening
2 = ON
Radio, no reversing in opening
3 = ON
Automatic closing
4 = ON
Pre-flashing enabled
5 = ON
Radio step-by-step
6 = ON
Dead man
Dip-switch B
1 = ON
Set braking duration
2 = ON
Set additional stop time after braking when safety devices are activated
3 = ON
Set electric lock or courtesy lamp duration
4 = OFF: blank
7 = ON
Flasher off in dwell time in automatic
8 = ON
Gate re-closing in opening and dwell on photocells engaging
9 = ON
DSA control of photocells before any movement
10 = ON
Photocells not obstructed before moving
11 = OFF: blank
12 = ON
Electronic brake enabled
Accessory
Dip-switch setting and LED indication of functions
Electrical connections
All NC contacts of safety accessories
such as photocells (receivers) must be
connected in series with terminals
1 and 2
24 Vac output
max load:
n° 1 radio receiver
n° 3 pairs photocells
ON
: stop gate/s in opening and reverse travel
in closing when cleared
OFF
: no stop in opening and reverse travel
in closing when obstructed
L1 ON
= no obstacle,
it goes off in case of obstruction
Key-switch:
NO and NC contacts to be connected
to the respective terminals in the
key-or button-switches.
All of the possible setting
combinations are described in the
instructions sheets included with the
respective control accessories
L4 OFF
= no OPENING contact,
it goes on whenever an opening pulse is given
L5 OFF
= no CLOSING contact,
it goes on whenever a closing pulse is given
L6 ON
= STOP contact closed,
it goes off whenever a stop pulse is given
COMMON
OPEN
CLOSE
STOP
ON
: it does not stop and reverse gate travel
in opening
OFF
: always stops & reverses in opening
DIP-SWITCH - A N° 2 and N° 5:
ON
: step by step with intermediate stop
OFF
: gate travel reversed by any radio pulse
Radio contact
(step by step mode):
Any NO connection to these two terminals
will perform the following:
- Opening only:
dip 2 = ON
and
dip 5 = OFF
- Gate travel reversing by any pulse
dip 2 = OFF
and
dip 5 = OFF
- Step by step: open-stop-close-stop
dip 2 = OFF
and
dip 5 = ON
- No new pulse is accepted in opening.
In dwell phase and in closing any new
pulses tops and reverses gate travel:
dip 2 = ON
and
dip 5 = ON
COMMON
RADIO
CONTACT
L7 OFF
= no RADIO contact,
it goes on by any radio pulse
Indication lamp output
24 V max 3 W:
Output for a 24 V max 3 W indication
lamp showing the status of the system:
Lamp
ON
= gate open
Lamp
OFF
= gate closed
0,5 s (fast)
flashing = gate closing
1 s (normal)
flashing = gate opening
COMMON