M1
pedestrian
phot
oc
ell
in closing
radio c
o
ntac
t
common
open
close
st
op
indication lamp 24
V
max 3
W
24 V
ac
output
max load:
n° 1 radio r
e
ceiv
er
n° 3 pairs phot
oc
ells
P
o
w
er supply f
o
r
elec
tric lock
15
V
A
max or indication lamp
230 Vac
OUTPUT for
flashing lamp
max 25 W
SINGLE-PHASE control
board power supply
230 V - 50/60 Hz ± 10%
NC
co
mmon
NEUTRAL
LIVE
common
L-
sw
.O
L-
sw
. C
THREE-PHASE control
board power supply
400 V - 50/60 Hz ± 10%
LIVE
LIVE
LIVE
Capacitor for
single-phase motors
ELECTRIC MOTOR
power supply
General description:
the electronic control box
ELPRO 37 DS
has been developed to provide a reliable unit to control double-leaf sliding gate automatic systems with or without electronic
brake and limit switches; single-phase 230 V - 50/60 Hz or three-phase 400 V - 50/60 Hz. The manufacturer is not liable for any incorrect use of this appliance; and also
reserves the right to change and update it without previous notice.
ATTENTION:
before starting the electrical connections, check the voltage (230 V or 400 V) selector switch to be set correctly.
In cases a motor with mechanical brake is used or a control board ELPRO 14 is replaced, the DIP-switch-A No.12 has to be in OFF.
!
NOTE:
the green LEDs must
always be on.
IN CASE OF FAILURE PLEASE MAKE SURE THAT:
- Power supply to the electronic control board is 230 V ±10% or 400 V ±10%.
- Power supply to the electric motor is 230 V ±10% or 400 V ±10%.
- All of the fuses is all right.
- The photocell contacts are closed.
- No voltage drop has occurred from the Elpro board to the electric motor.
- All of the NC contacts of the control board are all right.
- The limit switches are properly connected and work correctly.
Diagnostic LEDs:
L ON
= board on 230 V or 400 V voltage and F1, F2, F3, F4, F5, F6 fuses all right
L0 OFF
= pedestrian mode, it switches on by any pedestrian pulsing
L1 ON
= pair photocells in closing not obstructed
L4 OFF
= open, it switches on by any open pulse
L5 OFF
= close, it switches on by any close pulse
L6 ON
= stop, it switches off by any stop pulse
L7 OFF
= radio, it switches on by any pulse from the transmitter/radio contact
L8 ON
= it switches off when Fc.C (limit switch closing = L-sw.C) is engaged, M1
L10 ON
= it switches off when Fc.O. (limit switch opening = L-sw.O) is engaged, M1
L30 ON
= it switches off when Fc.C (limit switch closing = L-sw.C) is engaged, M2
L31 ON
= it switches off when Fc.O. (limit switch opening = L-sw.O) is engaged, M2
L33 ON
= safety edge protecting closing not obstructed
L34 ON
= safety edge or photocell protecting opening not obstructed
11
L
TRANSFORMER
UNL
ON
OFF
1
2
3
4
5
6
7
8
9 10 11 12
DIP-SWITCH - A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
24 Vac output
for photocell TX
enabling
DSA control
26
27
28
+
_
Power supply
24 V - 50 mA max
230 V
400 V
ON
OFF
1
2
3
4
DIP-SWITCH - B
ELPRO 37 DS
UNL
E 37
L0
L1
L4 L5 L6 L7 L8
L10
-
+
-
+
-
+
-
+
L33 L34
32 33
30 31
34
SAFETY EDGE
in OPENING
8,2 kΩ
or NC
L-sw
.C.2
L-sw
.O
.2
JA
1 2
SETUP
EDGE
TYPE
common
8,2 kΩ or NC
L30 L31
SAFETY EDGE
in CLOSING
LIMIT SWITCH
M2
ELECTRONIC BRAKE
INTENSITY
12
45
3
F3 = 16 A network
F2 = 16 A network
F1 = 16 A network
16
17
18
19 20
21
22
23
F5 = 630 mA flashing
light protection
F4 = 2 A transformer
and electronic brake
protection
38
39
F6 = 2 A protection 24 V
EARTH CONNECTION
Elpro 37 DS
M2
common
42
43
44
!
ATTENTION:
remove the connector of
single phase power supply
CONNECTION OF A SECOND
ELECTRIC MOTOR
SINGLE - THREE PHASE ELECTRONIC CONTROL BOARD
WITH ELECTRONIC BRAKE FOR DOUBLE-LEAF SLIDING GATE
AUTOMATIC SYSTEMS WITH OR WITHOUT LIMIT SWITCHES
GB
RUN
TIME
0 s - 120 s
DWELL
TIME
1 s - 220 s
PEDESTRIAN
1 s - 45 s
T.FUN
JB
1 2
PLUG-IN
RADIO
CARD
CONNECTOR
CARD
CONNECTOR FOR
TRAFFIC LIGHTS
(Item 7282L)
Capacitor for
single-phase
motors
ELECTRIC
MOTOR
power supply
IMPORTANT FOR THE INSTALLATION AND THE CORRECT FUNCTIONING:
- The control box must be installed in a dry and sheltered place.
- Make sure that power supply to the control board be 230 V ±10% or 400 V ±10%.
- Make sure that power supply to the electric motor be 230 V ±10% or 400 V ±10%.
- For distances longer than 50 metres increase the section of the wires.
- Fit the mains to the control box with a high sensitivity, 0,03 A, differential, magnetic-thermal circuit breaker.
- Cables with 1,5 mm² section wires are to be used for the power supply, electric motor and flasher for distances up to 50 m.
- Cables with 1 mm² section wires are to be used for the limit switches, photocells, push buttons and accessories.
- If no photocells are used link out terminals 1 and 2.
- If no stop button is used link out terminals 3 and 6.
- Open/close motor run time trimmer must be always superior to the time actually required for the gate travel.
N.W.: for applications such as light switching, CCTV, etc. use solid state relays to prevent the microprocessor from being affected.
SYMBOLS:
NO
contact
NC
contact
Resistive contact
8,2 kΩ or NC
Led
ON
Led
OFF
Pilot light
Flasher
istr_elpro37ds_GB.ai 2 04/07/2023 16:46:42