PIC. 16

- Carry out all the electrical connections to  the 

Elpro 13 CEI

 control panel

- First running test: set the 

Motor Run Time 09

 to a value  4-5 seconds higher than the time required by the gates to reach the gate stop;

set the 

Dwell Time 08

 (automatic mode) and 

Gate Delay Time in Closing Cycle 07

 (in case of double swinging gates) as required, pic. 16:

Automatic Mode: Dip-switch

 “

B

” No. 

3

 set to ON. Once an open pulse is given (to terminals 4 and 8 in Elpro 13 CEI main terminal

board, pic.16), the gates are driven to open, stopped for a time as set by the Dwell Time 08 and then automatically re-cycled to close.

Semi-automatic Mode: Dip-switch

 “

B

” No. 

3

  set to OFF. Once an open pulse is given, the gates are automatically operated only to

open; a second pulse (to terminals 5 and 8 in the Elpro 13 CEI main terminal board, pic.16) is needed to close the gates.

Radio Contact

: terminals 7 and 8 in the Elpro 13 CEI main terminal board, pic.16. Any pulse from a keyswitch, remote control or push

button reverses the gate travel (it is recommended to carefully read the instructions provided in the control box).

FEATURES OF THE ELECTRONIC PROGRAMMER FOR SWINGING GATES

All the electrical connections are to be made as per the following instructions and diagrams. Supply the terminals 24-25 with 230V -
50 Hz single phase voltage. The “red LED” switches on and stays on as long as the board is properly supplied. Through the timer No. 9
you can control the running time of the motor in both cycles, OPEN and CLOSE.
Set it so that the running time of the motor is longer than the actual travel of the gate: set the timer No. 8 -DWELL- ie. the interval between
open and re-closing, so that you can meet the required interval of time.
- With the electric motor connected to terminals 19 - 20 - 21: the delay is operative in the “open” cycle, with a factory pre-set time.
- With the electric motor connected to terminals 16 - 17 - 18: the delay is operative in “close” cycle and can be adjusted through the

timer No. 7 on to “less” or “more”.

LOGIC OF THE ELECTRONIC PROGRAMMER

: When a pulse is given, the flashing light switches on. After three seconds the motors start.

During the interval before re-closing, the light stays on. When the gates are fully re-closed, the light keeps on flashing for three more
seconds and then switches off automatically.
The 3 second interval (pre-flashing) which precedes the actual start of the motors can be eliminated by means of the DIP-SWITCH “B”
No.4.

LED No. 1: It switches on when voltage is supplied.
LED No. 2: “PHOTOCELLS”. Normally on. It switches off when the photocells are obstructed.
LED No. 3: “OPEN”. It switches on when the respective switch is activated.
LED No. 4: “CLOSE”. It switches on when the respective switch is activated.
LED No. 5: “STOP”. Normally on. It switches off when the respective switch is activated.
LED No. 6: “RADIO”. It switches on whenever a pulse is given, either from remote control, keyswitch or push buttons.

DIP-SWITCH 

B

 SETTING IN ELPRO 13 CEI

N

°

 1 OFF  = PHOTOCELLS. NO STOP IN OPEN CYCLE. REVERSE/CLOSE

N

°

 2 OFF  = REMOTE CONTROL. REVERSE

N

°

 3 OFF  = NO AUTOMATIC RECLOSING

N

°

 4 OFF  = NO PRE-FLASHING

N

°

 5 OFF  = REMOTE CONTROL. NO STOP AND HOLD AS LONG

   AS BUTTON DOWN. IT OPENS STRAIGHT AWAY

N

°

 6 OFF  = BOTH LEAFS ARE OPERATED

N

°

 7 OFF  = STROKE REVERSING PULSE OUT OF SERVICE

N

°

 8 OFF  = LEAF DELAY OPEN CYCLE.

   ONE STARTS BEFORE THE OTHER

LAMP ON = GATE OPEN
LAMP FLASHES SLOWLY = GATE OPENING
LAMP FLASHES FAST = GATE CLOSING
LAMP OFF = GATE CLOSED

1) It is advisable not to expose the control box directly to weather conditions; if mounted outside, a suitable enclosure is recommended

to protect it from sunshine and rain.

2) Bridge terminals 1 - 2 if you do not require any photocells.
3) Should two sets of photocells be required, these are to be series connected to terminals 1 - 2, contact normally closed.
4) Bridge terminals 6 - 8 if you do not require any keyswitch or push buttons.
5) Fit the mains to the control box with a high sensitivity, differential, magnetic-thermal switch, 0.03 Amps.
6) OPERATING MODE WITH TWO PAIRS OF PHOTOCELLS, INDEPENDENT FROM EACH OTHER

Dip-switch No. 1 set to OFF, connect the pair of photocells that are inside the property to the terminals marked  “2nd pair”.
The second pair always stops the gate in open cycle in case of an obstacle.
During close cycle the second pair reverses the gate direction.

7) NOTE WELL
FAULT FINDING:
- Check supply voltage with a tester: it must be 230 V, single-phase.
- Check the high voltage fuses.
- Check the low voltage fuses.
- Check if the photocell contacts are normally closed.
- Check voltage from the control box to the electric motor(s): power might have dropped.
- The section of the electric cables to the motor(s) must not be less than 1.5 mm

2

.

- Connect the other pair to the terminals 1 - 2
This pair performs in the standard pre-set mode, ie:
no stop during open cycle, REVERSING GATE DIRECTION DURING CLOSE CYCLE.
Terminals to stay linked out should the second pair of photocells not be used, and set the desired operating mode through Dip-switch
No. 1.
* 24 V ~ output. Terminals 12 - 13. It can supply power for 2 pairs of photocells plus 1 radio receiver.
Terminal 11 provides a power output for a lamp. 24 V - 3 Wmax.
Flashing lamp output. Terminals 22 - 23. Maximun available power 25 Wmax.

LEAF DELAY

TIMER

CLOSE

+

0

7

8

9

+

+

MOTOR RUN
TIME OPEN
& CLOSE

ON TO “0” THE DELAY
IS OUT OF SERVICE

DWELL TIME

FADINI

MICROPROCESSOR

TERMINALS FOR THE

CONNECTION OF THE

PUSH BUTTONS PULIN 3

26
27
28

PEDESTRIAN MODE
ONE PULSE OPENS
ONE GATE LEAF ONLY

PULSE TWICE CONSECUTIVELY

TO OPEN BOTH GATE LEAFS

3

4

ALL OPERATIONS

OPEN, CLOSE &

REVERSE

RADIO CONTACT

7

8

DIP-SWITCH

ON

ON

B

OFF

1

2

4

3

5 6 7 8

1

2

3

4

5

6

RADIO CONTROL
PLUG-IN CARD SUPPORT

24 V OUTPUT

1

°

 CHANNEL

CAPACITORS

12,5 

µ

F

12,5 

µ

F

230 V - 25 W max

FLASHING LAMP

230 V SINGLE-PHASE
SUPPLY VOLTAGE

ELECTRIC MOTORS
SINGLE-PHASE

COMMON

COMMON

M1

16

25

24

23

22

21

20

19

18

17

M2

630 mA

FUSE

F4

1 FUSE:
24 V OUTPUT
TERMINALS 12 - 13

F5

5 FUSE

F2

630 mA

FUSE FLASHING

LAMP

5 FUSE

F3

F1

CUT OFF SWITCH

BY COVER KNOB

Should more pairs of photocells be required than

the recommended quantity, fit an auxiliary

transformer outside the control box.

-PHOTOCELLS 2nd P

AIR-

INSIDE PHOTOCELLS N.C. contact. If

obstructed, they prevent the gates from

opening, reverse gate direction during

close cycle.

4

3

2

1

13

12

11

10

9

8

7

6

5

24 V - 3 W max. INDICA

TOR

VOL

TAGE OUTPUT

ELECTRIC LOCK SUPPL

Y

COMMON

RADIO CONT

ACT N.O.

STOP SWITCH N.C. CONT

ACT

CLOSE SWITCH N.O. CONT

ACT

OPEN SWITCH N.O. CONT

ACT

COMMON

N.C. CONT

ACT

.

PHOTOCELLS

24 V

ac OUTPUT

Max. permitted load:

2 pairs photocells

1 radio receiver

FOR SWING GATES

SINGLE-PHASE

N. W.: for special applications, ie. to switch on lights -
CCTV etc…, SOLID STATE RELAYS are recommended to
be used only.
Standard relays would affect the micro-processor.

N.W.: THIS PANEL IS TESTED TO OPERATE GATES ONLY
THROUGH FADINI ACCESSORIES. NO GUARANTEE FOR
ACCESSORIES OF OTHER MAKE OR SPECIAL
APPLICATIONS.

Drwg. 2014

N

°

 1 ON  = STOP DURING OPEN CYCLE

N

°

 2 ON  = NO REVERSE DURING OPEN CYCLE

N

°

 3 ON  = AUTOMATIC RECLOSING

N

°

 4 ON  = PRE-FLASHING

N

°

 5 ON  = STOP AND HOLD AS LONG AS

 

   THE BUTTON IS KEPT DOWN

N

°

 6 ON  = PEDESTRIAN. ONE LEAF ONLY

   GATES IN CLOSED POSITION

N

°

 7 ON  = S. R. P. IN SERVICE

   GATES IN CLOSED POSITION

N

°

 8 ON  = NO LEAF DELAY

  BOTH MOTORS START TOGETHER

Содержание DRIVE 700

Страница 1: ...stroke 52mm Working temperature 20 C 80 C Oil volume 0 25dm3 Static gate weight 700Kg PERFORMANCE Duty cycle 23 s Opening 30 s Dwell 23 s Closing Time of one complete cycle 76s No of complete cycles O...

Страница 2: ...stem PIC 2 DRIVE 700 PIC 1 GATE STOP IN OPEN GATE POSITION ENCLOSURE GUIDE BASE PLATE FIXING ANGLES FIXING BASE PLATE ENCLOSURE LID NERROW SECTION ENCLOSURE LID LARGE SECTION MOTOR PUMP UNIT MOTOR PUM...

Страница 3: ...stem PIC 2 DRIVE 700 PIC 1 GATE STOP IN OPEN GATE POSITION ENCLOSURE GUIDE BASE PLATE FIXING ANGLES FIXING BASE PLATE ENCLOSURE LID NERROW SECTION ENCLOSURE LID LARGE SECTION MOTOR PUMP UNIT MOTOR PUM...

Страница 4: ...position and the setting is maintained for long time By means of a wrench rotate the jack shaft until you can feel that the limit of the permitted stroke in closed gate position is reached in this po...

Страница 5: ...position and the setting is maintained for long time By means of a wrench rotate the jack shaft until you can feel that the limit of the permitted stroke in closed gate position is reached in this po...

Страница 6: ...as the photocells keyswitch etc FITTING THE ELECTRIC LOCK THE MECHANICAL LATCHING BOLT AND THE GATE STOPS It is recommended to fit the gates with an electric lock either vertically or horizontally pos...

Страница 7: ...as the photocells keyswitch etc FITTING THE ELECTRIC LOCK THE MECHANICAL LATCHING BOLT AND THE GATE STOPS It is recommended to fit the gates with an electric lock either vertically or horizontally pos...

Страница 8: ...if mounted outside a suitable enclosure is recommended to protect it from sunshine and rain 2 Bridge terminals 1 2 if you do not require any photocells 3 Should two sets of photocells be required thes...

Страница 9: ...if mounted outside a suitable enclosure is recommended to protect it from sunshine and rain 2 Bridge terminals 1 2 if you do not require any photocells 3 Should two sets of photocells be required thes...

Страница 10: ...ulic motor pump units both gates are to be operated in the same direction Should they fail to perform in a synchronized way swap the electrical motor connections ie live 1 and 2 for both gates to open...

Страница 11: ...ulic motor pump units both gates are to be operated in the same direction Should they fail to perform in a synchronized way swap the electrical motor connections ie live 1 and 2 for both gates to open...

Страница 12: ...stroke 52mm Working temperature 20 C 80 C Oil volume 0 25dm3 Static gate weight 700Kg PERFORMANCE Duty cycle 23 s Opening 30 s Dwell 23 s Closing Time of one complete cycle 76s No of complete cycles O...

Отзывы: