3

PIC. 2

PRELIMINARY OPERATION: SEPARATION OF THE POST ASSEMBLY

HYDRAULIC MOTOR PUMP

LOCATION ENCLOSURE

ENCLOSURE COVER PLATE

First operation. Once the enclosure  cover plate is removed, you can have access to the mechanism, and  the components  ie. the inner
motor pump and actuator assembly can be easily lifted out using mechanical aid. Pic.2
IMPORTANT: make sure the electric cables are not damaged or accidentally removed from termination.

POST COVER

EDGE PROTECTION RUBBER RING

LIFTING EYE

LIFTING

MECHANISM

RISING POST

HOUSING CYLINDER

AND PISTON ASSEMBLY

CABLE OF THE OPEN LIMIT
SWITCH (LOWERED POST),
10 METRE LENGTH

ELECTRIC MOTOR CABLE
10 METRE LENGTH

Содержание Coral 1080

Страница 1: ...FITTING INSTRUCTIONS GB...

Страница 2: ...ion soon after fixing the location enclosure fit the mechanism into it carry out the electrical connections and the system is ready to work Once a pulse is given either by keyswitch or remote control...

Страница 3: ...he components ie the inner motor pump and actuator assembly can be easily lifted out using mechanical aid Pic 2 IMPORTANT make sure the electric cables are not damaged or accidentally removed from ter...

Страница 4: ...side of the enclosure to the tube centre line Pic 13 and 14 Front view View of the side where a hole is provided for a cable duct to be fitted A hole will be required in the road surface where Coral 1...

Страница 5: ...ch cables should be pulled through the duct a rope pull through previously inserted and the inner assembly gently lowered onto the location enclosure IMPORTANT Pull the electric motor and limit switch...

Страница 6: ...ted as indicated in the diagram a 20 F capacitor in parallel with the two live terminals Control unit ELPRO 10 PLUS CEI Power supply 230V 50Hz Electric Motor Cable 20 F capacitor fitted inside Elpro 1...

Страница 7: ...square section of 1 5 mm2 for a distance not superior to 50 m For longer distances use 2 mm2 wires To connect the photo cells key or button operated switches and other accessories 1 mm2 wires can be u...

Страница 8: ...ing operations are recommended by a qualified technician in conformity to the existing safety standards The manufacturing company declines any responsability for incorrect handling and application als...

Страница 9: ...utomatic Mode 400V 50Hz THREE PHASE Holdonswitched Deadman control Pedestrian Opening Trimmer T3 OPERATING MODES from 3 to 30s It can be activated by any pulse eg by remote control superior to 2s 3 DI...

Страница 10: ...e 2A Control Unit ELPRO 10 PLUS CEI GREEN RED Mains Supply 230V 50Hz IMPORTANT For security reasons failure of the red light prevents even the green light from illuminating Interface for the electrica...

Страница 11: ...to lower the bollard 4 and eventually re establish normal operation by rotating the spanner clockwise to the original position 5 To re establish normal operation first turn the spanner clockwise to l...

Страница 12: ...stem which ensures constant quality standards updated knowledge of the European Standards and compliance with their requirements in view of an ever increasing process of improvement The CE mark certif...