Drwg. No.

4333

1

2

Button switch:

3

4

5

6

Photocells and Safety Edge:

12 13

PHOTOCELLS AND
SAFETY EDGE

24V OUTPUT (MAX. LOAD:
2 PAIRS PHOTOCELLS
1 RADIO RECEIVER)

Push Button Switch Pulin 3:

26

27

28

3

COMMON

Led to indicate status
of Open - Stop - Close
switches

RS RS

Connect a 12VAC
Relay (T4 Trimmer
Time from 2s to 255s)
to operate a 230V
lamp

Electric lock:

RS RS

Set the T4 Trimmer Time
to the lowest value The
electric lock is excited
for 2 seconds

7

3

LOW VOLTAGE ELECTRICAL CONNECTIONS

1

DIP-SWITCH 1:

ON: Photocells stop gate while opening,
       reverse it on closing once obstacle is
       removed

OFF: Photocells do not stop gate while
        opening, reverse it on closing in
        case of an obstacle

STOP

COMMON

OPEN

CLOSE

Limit switch:

10

COMMON

8

9

LIMIT SWITCH

CLOSE

LIMIT SWITCH

OPEN

Radio Contact:

COMMON

RADIO

CONT

ACT

- Open/Close (Standard)
- Travel reversing on
  pulsing
- Step by step

2

5

ON: Step by step. Stop in between

OFF: Standard operating mode

ON: Gate is not reversed while opening

OFF: Any pulse reverses the gate

DIP-SWITCH 2 and 5 (NEVER set BOTH of
them to ON at the same time):

Light

 

ON

 = Open gate

Light

 

OFF

 = Closed gate

Flashing 

(fast) 0.5s

 

= Closing gate

Flashing 

(normally) 1s 

= Opening gate

Flashing 

(slowly) 2s

 

= gate is stopped

24V 3W Indication Light:

3

11

Courtesy light:

Flashing lamp:

19 20

 230V MAX 25W

4

Power supply:

Single- and Three-
phase Motors:

ELECTRIC POWER CONNECTIONS

-

+

T1

MOTOR RUN TIME

OPEN / CLOSE
from 5 to 128s

T2

-

+

DWELL TIME

from 5 to 128s

7

230V

400V

CAPACITOR

18

16

17

COMMON

M

MOTOR

U

W

V

230V 50Hz SINGLE-

PHASE

21

22

NEUTRAL

S

LIVE

23

22

DIP-SWITCH 4 and 7:

21

22

T

R

S

LIVE

23

22

ON: Pre-flashing

OFF: No pre-flashing

ON: Lamp is not operating during
       Dwell Time. Automatic Mode.
OFF: It flashes during Dwell Time.
        Automatic Mode.

400V 50Hz THREE-

PHASE

Hold on switched (Deadman) control:

Pedestrian Opening:

Trimmer T3

-

+

OPERATING MODES

from 3 to 30s. It can be activated by

any pulse (eg. by remote control)

superior to 2s

3

DIP-SWITCH 3

ON= Automatic Closing

OFF= No Automatic. Semi-automatic
          closing by pulse

Automatic / Semiautomatic:

Automatic Operation:

 any pulse opens the gate, the gate stays

open as long as the Dwell time expires as set by T2 trimmer, then
it closes automatically, no pulsing is required.

Semi-automatic Operation:

 any pulse opens the gate that stays

open. A second pulse to Close is required for the gate to close.

Open and Close operations are achieved "by holding a
switch on" (no relay self-holding is involved) therefore a
phisical attendance is required to keep the gate opening
or closing until either the button or key is released.

Remote Controlled Operations Excluded
during Dwell Time on Automatic Mode:

3

ON= Automatic Closing

OFF= Closing by Pulse

5

ON: Step by step. Stop in between

OFF: Standard Operations

With this setting it is not possible to operate the gate by remote control during the dwell time on automatic mode.
DIP-SWITCH 2=ON, 3=ON and 5=ON

DIP-SWITCH 6

6

ON= Deadman Control. Dip-switch 4=OFF
         and Dip-switch 3=OFF

OFF= Standard Operations

How it works: Set the clock to the required time. On the pre-set time the gate is automatically opened and held open. Any further pulsing (even
by remote control) is not accepted by the system until the time pre-set by the clock has expired. On expiring and after the pre-set dwell time
the gate is closed automatically.
T3 trimmer on to zero, Dip-Switch 3=ON.

DIP-SWITCH No.3=ON Automatic Closing

Time clock:

3

ON= Automatic Closing

OFF= No Automatic. Semi-automatic
          closing by pulse

4

3

COMMON

COMMON

OPEN

NO

-

+

Pedestrian Trimmer 

T3

set on to zero

2

ON: No reversing on opening

OFF: Travel reversing on any pulsing

Dwell Time

from 5 to 128s

T2

-

+

COMMON

OPEN

4

3

LIVE

LIVE

Содержание Coral 1080

Страница 1: ...FITTING INSTRUCTIONS GB...

Страница 2: ...ion soon after fixing the location enclosure fit the mechanism into it carry out the electrical connections and the system is ready to work Once a pulse is given either by keyswitch or remote control...

Страница 3: ...he components ie the inner motor pump and actuator assembly can be easily lifted out using mechanical aid Pic 2 IMPORTANT make sure the electric cables are not damaged or accidentally removed from ter...

Страница 4: ...side of the enclosure to the tube centre line Pic 13 and 14 Front view View of the side where a hole is provided for a cable duct to be fitted A hole will be required in the road surface where Coral 1...

Страница 5: ...ch cables should be pulled through the duct a rope pull through previously inserted and the inner assembly gently lowered onto the location enclosure IMPORTANT Pull the electric motor and limit switch...

Страница 6: ...ted as indicated in the diagram a 20 F capacitor in parallel with the two live terminals Control unit ELPRO 10 PLUS CEI Power supply 230V 50Hz Electric Motor Cable 20 F capacitor fitted inside Elpro 1...

Страница 7: ...square section of 1 5 mm2 for a distance not superior to 50 m For longer distances use 2 mm2 wires To connect the photo cells key or button operated switches and other accessories 1 mm2 wires can be u...

Страница 8: ...ing operations are recommended by a qualified technician in conformity to the existing safety standards The manufacturing company declines any responsability for incorrect handling and application als...

Страница 9: ...utomatic Mode 400V 50Hz THREE PHASE Holdonswitched Deadman control Pedestrian Opening Trimmer T3 OPERATING MODES from 3 to 30s It can be activated by any pulse eg by remote control superior to 2s 3 DI...

Страница 10: ...e 2A Control Unit ELPRO 10 PLUS CEI GREEN RED Mains Supply 230V 50Hz IMPORTANT For security reasons failure of the red light prevents even the green light from illuminating Interface for the electrica...

Страница 11: ...to lower the bollard 4 and eventually re establish normal operation by rotating the spanner clockwise to the original position 5 To re establish normal operation first turn the spanner clockwise to l...

Страница 12: ...stem which ensures constant quality standards updated knowledge of the European Standards and compliance with their requirements in view of an ever increasing process of improvement The CE mark certif...

Отзывы: