5

40 cm

75 cm

15 cm

1,30 m

PIC. 6

PIC. 7

- Once located the enclosure into the pit, it is important that the
top edge is flush with the ground level.
- Fill with soil up to 75 cm and the remaining 40 cm with concrete
Pic. 6.

INNER ASSEMBLY INSTALLATION

For this operation it is fundamental that the location enclosure is
very firmly set in its foundation, therefore it has to be carried out
only after you are satisfied that the concrete is well set and the
electrical duct coupled to the enclosure and laid under the ground.
- A suitable lifting harness should be passed through the eye in
the bollard top and attached to a lifting mechanism. The assembly
should be raised from the ground and positioned  directly above
the location enclosure.
- Next step. The motor and the limit switch cables should be pulled
through the duct (a rope pull-through previously inserted), and
the inner assembly gently lowered onto the location enclosure.

IMPORTANT: Pull the electric motor and limit switch cables through
the duct to the control unit. Be careful not to damage or remove
the cables from their termination Pic.7.

Once satisfied that the guide tube assembly is properly fitted inside the location enclosure, fit back the bollard lid and the enclosure
cover plate (Pic. 8 on page 6).

FRONT SIDE

BACK SIDE

IMPORTANT: Once the installation
operations are completed the
enclosure top edge must be flush
with road surface

75 cm

 approx. Fill this

distance with soil

40 cm

 approx. Fill this

distance with concrete

Concrete foundation

15 cm

 approx. Shingle to

clear of standing water

Foundation

enclosure

Guide tube

assembly

FRONT SIDE

Electronic control unit

Elpro 10 PLUS CEI

Ø50 mm duct laid
under the ground

Lifting harness

Electric motor and limit
switch cables, 10 m length

Содержание Coral 1080

Страница 1: ...FITTING INSTRUCTIONS GB...

Страница 2: ...ion soon after fixing the location enclosure fit the mechanism into it carry out the electrical connections and the system is ready to work Once a pulse is given either by keyswitch or remote control...

Страница 3: ...he components ie the inner motor pump and actuator assembly can be easily lifted out using mechanical aid Pic 2 IMPORTANT make sure the electric cables are not damaged or accidentally removed from ter...

Страница 4: ...side of the enclosure to the tube centre line Pic 13 and 14 Front view View of the side where a hole is provided for a cable duct to be fitted A hole will be required in the road surface where Coral 1...

Страница 5: ...ch cables should be pulled through the duct a rope pull through previously inserted and the inner assembly gently lowered onto the location enclosure IMPORTANT Pull the electric motor and limit switch...

Страница 6: ...ted as indicated in the diagram a 20 F capacitor in parallel with the two live terminals Control unit ELPRO 10 PLUS CEI Power supply 230V 50Hz Electric Motor Cable 20 F capacitor fitted inside Elpro 1...

Страница 7: ...square section of 1 5 mm2 for a distance not superior to 50 m For longer distances use 2 mm2 wires To connect the photo cells key or button operated switches and other accessories 1 mm2 wires can be u...

Страница 8: ...ing operations are recommended by a qualified technician in conformity to the existing safety standards The manufacturing company declines any responsability for incorrect handling and application als...

Страница 9: ...utomatic Mode 400V 50Hz THREE PHASE Holdonswitched Deadman control Pedestrian Opening Trimmer T3 OPERATING MODES from 3 to 30s It can be activated by any pulse eg by remote control superior to 2s 3 DI...

Страница 10: ...e 2A Control Unit ELPRO 10 PLUS CEI GREEN RED Mains Supply 230V 50Hz IMPORTANT For security reasons failure of the red light prevents even the green light from illuminating Interface for the electrica...

Страница 11: ...to lower the bollard 4 and eventually re establish normal operation by rotating the spanner clockwise to the original position 5 To re establish normal operation first turn the spanner clockwise to l...

Страница 12: ...stem which ensures constant quality standards updated knowledge of the European Standards and compliance with their requirements in view of an ever increasing process of improvement The CE mark certif...

Отзывы: