fadini Coral 1080 Скачать руководство пользователя страница 4

4

PIC. 4

PIC. 5

PIC. 3

400 mm

330 mm

170 mm

Ø195 mm

165

 mm

165

 mm

200 mm

230 mm

800 mm

790 mm

395 mm

395 mm

200

200

400

330

130

165

970 mm

1˙140 mm

1,30 m

INSTALLATION OF THE LOCATING ENCLOSURE

The foundation enclosure is the component that is designed to house the automation and it should be set into the ground so that
the top of it is at ground level.

IMPORTANT:

 the upper square section of the foundation enclosure (where the motor pump unit is to be fitted) is not centered to the

lower tube where the  guide tube and piston assembly are to be located: there is a distance of 13 cm from the "back side" of the
enclosure to the tube centre line (Pic. 13 and 14).

Front view

View of the side where a hole is

provided for a cable duct to be fitted

- A hole will be required in the road surface where Coral 1080 is to be located, as indicated in Pic. 5.  Provision is made within the
unit for the entry of a Ø 50 mm duct to the electronic control unit (the cables are 10 m long). Provide a soakaway by pouring shingle
into the hole up to 15 cm from bottom level.

Front side

Back side

FRONT SIDE

BACK SIDE

Depth to hole
centre 120 mm

FRONT SIDE

BACK SIDE

15 cm

Shingle to provide
a soakaway

12 cm

Depth from duct centre.
This duct to lead the cables
to the control unit

Ø50 mm duct  for the
cables to be connected
to the control panel
(cable length 10 metres)

Locating tube

Electronic

control unit

Elpro 10 PLUS CEI

Содержание Coral 1080

Страница 1: ...FITTING INSTRUCTIONS GB...

Страница 2: ...ion soon after fixing the location enclosure fit the mechanism into it carry out the electrical connections and the system is ready to work Once a pulse is given either by keyswitch or remote control...

Страница 3: ...he components ie the inner motor pump and actuator assembly can be easily lifted out using mechanical aid Pic 2 IMPORTANT make sure the electric cables are not damaged or accidentally removed from ter...

Страница 4: ...side of the enclosure to the tube centre line Pic 13 and 14 Front view View of the side where a hole is provided for a cable duct to be fitted A hole will be required in the road surface where Coral 1...

Страница 5: ...ch cables should be pulled through the duct a rope pull through previously inserted and the inner assembly gently lowered onto the location enclosure IMPORTANT Pull the electric motor and limit switch...

Страница 6: ...ted as indicated in the diagram a 20 F capacitor in parallel with the two live terminals Control unit ELPRO 10 PLUS CEI Power supply 230V 50Hz Electric Motor Cable 20 F capacitor fitted inside Elpro 1...

Страница 7: ...square section of 1 5 mm2 for a distance not superior to 50 m For longer distances use 2 mm2 wires To connect the photo cells key or button operated switches and other accessories 1 mm2 wires can be u...

Страница 8: ...ing operations are recommended by a qualified technician in conformity to the existing safety standards The manufacturing company declines any responsability for incorrect handling and application als...

Страница 9: ...utomatic Mode 400V 50Hz THREE PHASE Holdonswitched Deadman control Pedestrian Opening Trimmer T3 OPERATING MODES from 3 to 30s It can be activated by any pulse eg by remote control superior to 2s 3 DI...

Страница 10: ...e 2A Control Unit ELPRO 10 PLUS CEI GREEN RED Mains Supply 230V 50Hz IMPORTANT For security reasons failure of the red light prevents even the green light from illuminating Interface for the electrica...

Страница 11: ...to lower the bollard 4 and eventually re establish normal operation by rotating the spanner clockwise to the original position 5 To re establish normal operation first turn the spanner clockwise to l...

Страница 12: ...stem which ensures constant quality standards updated knowledge of the European Standards and compliance with their requirements in view of an ever increasing process of improvement The CE mark certif...

Отзывы: