![fadini Coral 1080 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/fadini/coral-1080/coral-1080_fitting-instructions-manual_3165334004.webp)
4
PIC. 4
PIC. 5
PIC. 3
400 mm
330 mm
170 mm
Ø195 mm
165
mm
165
mm
200 mm
230 mm
800 mm
790 mm
395 mm
395 mm
200
200
400
330
130
165
970 mm
1˙140 mm
1,30 m
INSTALLATION OF THE LOCATING ENCLOSURE
The foundation enclosure is the component that is designed to house the automation and it should be set into the ground so that
the top of it is at ground level.
IMPORTANT:
the upper square section of the foundation enclosure (where the motor pump unit is to be fitted) is not centered to the
lower tube where the guide tube and piston assembly are to be located: there is a distance of 13 cm from the "back side" of the
enclosure to the tube centre line (Pic. 13 and 14).
Front view
View of the side where a hole is
provided for a cable duct to be fitted
- A hole will be required in the road surface where Coral 1080 is to be located, as indicated in Pic. 5. Provision is made within the
unit for the entry of a Ø 50 mm duct to the electronic control unit (the cables are 10 m long). Provide a soakaway by pouring shingle
into the hole up to 15 cm from bottom level.
Front side
Back side
FRONT SIDE
BACK SIDE
Depth to hole
centre 120 mm
FRONT SIDE
BACK SIDE
15 cm
Shingle to provide
a soakaway
12 cm
Depth from duct centre.
This duct to lead the cables
to the control unit
Ø50 mm duct for the
cables to be connected
to the control panel
(cable length 10 metres)
Locating tube
Electronic
control unit
Elpro 10 PLUS CEI
Содержание Coral 1080