manualshive.com logo in svg
background image

CORAL

8

Pic. 9

Pic. 7

Pic. 8

MAGNETIC LOOP PREPARATIONS

ARRANGEMENT OF THE PHOTOCELLS

The magnetic loop detector is a safety device operating all the time to detect any transiting vehicle: the bollard is prevented from 
rising should a vehicle cross the loop.
A hole is to be dug in the ground as indicated (see relative instructions sheet). For proper and correct functioning of the loop 
detector it is recommended to strictly keep to the installation geometry as indicated in the instructions.

IMPORTANT:

make sure that no other electro-magnetic sources are located on or under the ground near the installation to 

prevent interference or any affecting action with the magnetic loops of the vehicle detecting device if installed or 

with any other electronic equipment included in the system for commanding and controlling operations.

Loop in

entry gateway

Loop in

entry gateway

Loop in

exit gateway

Loop in

exit gateway

min 80 cm

Elpro S40

ZERO.PT

ZERO.PT

ZERO.PT

Electric cables laid in the ground in a corrugated sheath

ZERO.PT

Visual 344

Ø 275

CORAL bollard

Power supply cable

10 meters max,

pre- tted to the loops

Metal detector.

See instructions included

with the equipment

(optional in the catalogue)

• Pre-assembled loop 

6 meters

 across

  (optional in the catalogue)

• Pre-assembled loop 

12 meters

 across

  (optional in the catalogue)

ZERO.K

fully retractable oil-hydraulic bollard

!

Содержание CORAL 1050

Страница 1: ...EN 13241 EN 12453 EN 12445 CORAL 1050 1063 1080 Instructions manual pages 1 16 the gate opener FULLY RETRACTABLE OIL HYDRAULIC BOLLARDS POST DIAMETER 100 mm HALL MAGNETIC LIMIT SWITCH GB...

Страница 2: ...ith a pedestrian entrance it is appropriate to prepare the system in such a way to prohibit the operation of the engine when the pedestrian entrance is used Apply safety nameplates with CE marking on...

Страница 3: ...erator can be introduced ready for operation as soon as the wiring has been completed As soon as the retractable post receives a command from a key switch or radio transmitter it rises from its interr...

Страница 4: ...tail of retractable post with hoisting connection PRELIMINARY OPENING OF ALL FUNCTIONAL COMPONENTS Start by removing the cover plate to reveal the operator and separate the individual components with...

Страница 5: ...res use electric cables with sections suited to the installation Pic 3 230V 50 Hz 1 2 3 4 5 6 6 7 2x1 mm 2x1 mm 3x1 mm 4x1 mm 4x1 mm 4x1 mm 8 10 11 8 9 1 Led ashing light with built in aerial 2 Stand...

Страница 6: ...Pic 4 Pic 5 IMPORTANT once the housing has been positioned and installation completed it is important for the top edge to be level with the ground Piping 5 cm for passage of electric wires Concrete c...

Страница 7: ...r inside the housing Pic 6 IMPORTANT PASS THE MOTOR LIMIT SWITCH SOLENOID VALVE AND LED POWER SUPPLY ELECTRIC WIRES THROUGH THE PIPING WITHOUT TEARING OR CUTTING THE CABLES Hoisting hook Oil hydraulic...

Страница 8: ...near the installation to prevent interference or any a ecting action with the magnetic loops of the vehicle detecting device if installed or with any other electronic equipment included in the system...

Страница 9: ...are properly alight the post should move up on the rst commanding pulse should it fail disconnect power supply and swap the connections to the live terminals NOTE WELL supply the system with electric...

Страница 10: ...GROUND LEVEL CLOSURE COVER PLATE Use the four screws to close the cover plate Lift the retractable post for facilitate closure of the post cover with the bu er give the command by encoding a transmit...

Страница 11: ...ds IP 67 A 40 C with speci c optional accessories Ref General Catalogue PERFORMANCE CORAL 1050 Frequency of use intensive Service cycle rise 4 7 s dwell 30 s lower 4 4 s dwell 30 s Complete cycle time...

Страница 12: ...lard to avoid that settling at a later stage causes problems to the system 5 Make sure the site is free from utilities that may interfere with it 6 Make sure that electromagnetic sources are at a suit...

Страница 13: ...CORAL 13 fully retractable oil hydraulic bollard...

Страница 14: ...14 CORAL fully retractable oil hydraulic bollard...

Страница 15: ...antity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation maintenance repairs and replacements to be made only by us...

Страница 16: ...extra capacitor to the existing one instructions manual is to be referred to Check the correct functioning of the signal LED lights if incorporated in the bollard head Sight check the electronic board...