manualshive.com logo in svg
background image

12

PRODUCT SPECIFICATIONS

Heavy duty, fully retractable, automatic bollard made up of an incorporated oil-hydraulic motor pump unit and an oil-hydraulic 
actuator inside the moving cylinder. Suitable for applications in private and commercial areas, and for industrial installations. 
IP67. The height of the rising cylinder (from ground level) can be 500/600/800 mm. The rising cylinder is made of S235JRH steel, 
thickness 5 mm and Ø 100 mm, cataphoresis treated and powder coated. Rubber ring on cylinder head. Cataphoresis treated 
aluminium cover with slip proof  nish on treadable top. Rising cylinder  tted with high intensity, microprismatic, retrore ecting 
approved sticker (h 80 mm), available with signal LEDs (N.4) with  ashing light  tted all around the top. Hot dip galvanized steel 
casing for ground foundation,  tted with a cover allowing access to the hydraulic release for manual lowering of the bollard by 
a  special  spanner  in  an  emergency.  Impact  resistance  30.000  J,  breakout  resistance  150.000  J,  static  load  max  1.600  kg  in 
standing position, max 20.000 kg in lowered position. Working temperature -40 °C +80 °C. Supply voltage 230 Vac ± 10%, 50 Hz. 
Absorbed power 330 W. Rising time ~ 4,7 s [rising cylinder H 500 mm], ~ 5,6 s [rising cylinder H 600 mm] ~ 7,5 s [rising cylinder 
H  800 mm].  Frequency  of  use  2.000 cycles/day.  Hydraulic device to  lock  the bollard in the  standing  position,  on  request  a 
solenoid valve can be  tted for the spontaneous descent of the bollard in case of a power failure.

1) Installation operations, testing, analysis of the risks and future maintenance are to be executed by quali ed and authorized 

technicians in compliance with the existing regulations (www.fadini.net/supporto/download).

2) This automatic system is intended to be exclusively used for the applications described in this manual, including all of the 

safety and command accessories, at least as required.

3) Any application not indicated in this manual may cause malfunctioning or damages to people and properties.

4) Make sure the soil is adequate to take the bollard to avoid that settling at a later stage causes problems to the system.

5) Make sure the site is free from utilities that may interfere with it.

6) Make sure that electromagnetic sources are at a suitable distance from the accessories, especially from the loop detectors. 

The magnetic  elds of other sources might affect the detections of the safety loops as well as those of the other command and 

safety devices of the system.

7) Make sure the power supply to the electric motor is 230 V (50 Hz).

8) 

It is recommended either of the following power supply cables:

- 10 meters electric cable 4x1 mm² for motor pump power supply;

- 10 meters electric cable 3x0,5 mm² for limit switches.

The section of the ground cable is to be chosen in compliance with the requirements of the installation site.

9) In case any components or accessories need replacing, use only original parts as provided by the manufacturer.

10) The installer shall provide the  nal user with information related to all of the operating commands and functions of the 

system, including that concerning lowering of the post in case of an emergency (manual release operation).

11) The installer shall inform the  nal user of the dangers coming from the presence of persons, especially children, in the 

proximity of the bollard. 

12) The manufacturer reserves the right to change this manual without previous notice.

As far as con guration and  execution of the system are concerned, these are to  comply  with the laws in the country of 

installation.

Meccanica Fadini is not liable for any possible damages derived from incorrect use or from any use not indicated in this 

manual, furthermore it is not answerable for malfunctioning caused by the use of materials or accessories not approved by 

the company itself.

It  is  to  be  noted  that  the  product  respects  the  impact  and  breakout  resistance  values  as  indicated  provided  that  the 

installation of the same is carried out in observance of the speci cations included in this manual of instructions. Various 

factors are to be carefully taken into consideration such as compaction index, soil permeability coefficient, concrete type, 

which may affect the indicated values even signi cantly.

WARNINGS

CORAL

fully retractable oil-hydraulic bollard

Содержание CORAL 1050

Страница 1: ...EN 13241 EN 12453 EN 12445 CORAL 1050 1063 1080 Instructions manual pages 1 16 the gate opener FULLY RETRACTABLE OIL HYDRAULIC BOLLARDS POST DIAMETER 100 mm HALL MAGNETIC LIMIT SWITCH GB...

Страница 2: ...ith a pedestrian entrance it is appropriate to prepare the system in such a way to prohibit the operation of the engine when the pedestrian entrance is used Apply safety nameplates with CE marking on...

Страница 3: ...erator can be introduced ready for operation as soon as the wiring has been completed As soon as the retractable post receives a command from a key switch or radio transmitter it rises from its interr...

Страница 4: ...tail of retractable post with hoisting connection PRELIMINARY OPENING OF ALL FUNCTIONAL COMPONENTS Start by removing the cover plate to reveal the operator and separate the individual components with...

Страница 5: ...res use electric cables with sections suited to the installation Pic 3 230V 50 Hz 1 2 3 4 5 6 6 7 2x1 mm 2x1 mm 3x1 mm 4x1 mm 4x1 mm 4x1 mm 8 10 11 8 9 1 Led ashing light with built in aerial 2 Stand...

Страница 6: ...Pic 4 Pic 5 IMPORTANT once the housing has been positioned and installation completed it is important for the top edge to be level with the ground Piping 5 cm for passage of electric wires Concrete c...

Страница 7: ...r inside the housing Pic 6 IMPORTANT PASS THE MOTOR LIMIT SWITCH SOLENOID VALVE AND LED POWER SUPPLY ELECTRIC WIRES THROUGH THE PIPING WITHOUT TEARING OR CUTTING THE CABLES Hoisting hook Oil hydraulic...

Страница 8: ...near the installation to prevent interference or any a ecting action with the magnetic loops of the vehicle detecting device if installed or with any other electronic equipment included in the system...

Страница 9: ...are properly alight the post should move up on the rst commanding pulse should it fail disconnect power supply and swap the connections to the live terminals NOTE WELL supply the system with electric...

Страница 10: ...GROUND LEVEL CLOSURE COVER PLATE Use the four screws to close the cover plate Lift the retractable post for facilitate closure of the post cover with the bu er give the command by encoding a transmit...

Страница 11: ...ds IP 67 A 40 C with speci c optional accessories Ref General Catalogue PERFORMANCE CORAL 1050 Frequency of use intensive Service cycle rise 4 7 s dwell 30 s lower 4 4 s dwell 30 s Complete cycle time...

Страница 12: ...lard to avoid that settling at a later stage causes problems to the system 5 Make sure the site is free from utilities that may interfere with it 6 Make sure that electromagnetic sources are at a suit...

Страница 13: ...CORAL 13 fully retractable oil hydraulic bollard...

Страница 14: ...14 CORAL fully retractable oil hydraulic bollard...

Страница 15: ...antity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation maintenance repairs and replacements to be made only by us...

Страница 16: ...extra capacitor to the existing one instructions manual is to be referred to Check the correct functioning of the signal LED lights if incorporated in the bollard head Sight check the electronic board...

Отзывы: