manualshive.com logo in svg
background image

CORAL

11

TECHNICAL DATA

ELECTRIC MOTOR

Power output 

 

 

                 0,25 kW (0,33 HP)

Supply voltage 

 

 

                 230 Vac

Frequency 

 

 

                 50 Hz

Absorbed power 

 

 

                 400 W

Absorbed current   

 

                 1,8 ÷ 3,5 A (6 A)

Motor revolutions   

 

                 2.800 rpm

Capacitor  

 

 

                 20 µF

Service mode 

 

 

                 S3

HYDRAULIC ACTUATOR

Shaft diameter 

 

 

                 16 mm

Piston diameter 

 

 

                 30 mm

Pre-set pushing power 

 

                 15 daN

Protection standard complete   

                 IP 55

FEATURES

Impact resistance

Crash resistance

Max static load

Bollard weight

Post diameter

Post height

Post  nishing

Post material

Bollard thickness

Ground sleeve treatment

CORAL 1050

30.000 J

150.000 J

20.000 kg

86 kg

ø 100 mm

500 mm

powder coating polyester

anthracite grey RAL 7016

S235JRH steel

5 mm

hot dip galvanization

CORAL 1063

30.000 J

150.000 J

20.000 kg

90 kg

ø 100 mm

600 mm

powder coating polyester

anthracite grey RAL 7016

S235JRH steel

5 mm

hot dip galvanization

CORAL 1080

30.000 J

150.000 J

20.000 kg

104 kg

ø 100 mm

800 mm

powder coating polyester

anthracite grey RAL 7016

S235JRH steel

5 mm

hot dip galvanization

OIL-HYDRAULIC MOTOR-PUMP UNIT VICO 2240

Hydraulic pump 

 

 

P10

Pump  ow rate 

 

 

4,45 l/min

Working pressure   

 

20 atm

Max pressure 

 

 

40 atm

Working temperature 

 

-20 °C +80 °C 

[A]

Oil type   

 

 

Oil Fadini - Item 708L

Oil reservoire 

 

 

0,7 liters

Total weight (without oil) 

 

7 kg

Pump protection standards 

 

IP 67

[A]: -40 °C with speci c optional accessories (Ref. General Catalogue).

PERFORMANCE - CORAL 1050

Frequency of use 

              intensive

Service cycle 

              rise         ~4,7 s

 

 

              dwell         30 s

 

 

              lower     ~4,4 s

 

 

              dwell         30 s

Complete cycle time                ~69 s

Complete cycles

rise-dwell-lower-dwell              No. 52/hour

Annual cycles

(with 8 hours of use per day)  No. 151.840

PERFORMANCE - CORAL 1063

Frequency of use 

              intensive

Service cycle 

              rise         ~5,6 s

 

 

              dwell         30 s

 

 

              lower     ~5,1 s

 

 

              dwell         30 s

Complete cycle time              ~70 s

Complete cycles

rise-dwell-lower-dwell              No. 51/hour

Annual cycles

(with 8 hours of use per day)  No. 148.920

PERFORMANCE - CORAL 1080

Frequency of use 

              intensive

Service cycle 

              rise         ~7,5 s

 

 

              dwell         30 s

 

 

              lower     ~6,6 s

 

 

              dwell         30 s

Complete cycle time              ~74 s

Complete cycles

rise-dwell-lower-dwell              No. 48/hour

Annual cycles

(with 8 hours of use per day)  No. 140.160

Overall dimensions

Coral 1050

Coral 1063

Coral 1080

N.W.

 - Measurements are in millimeters (mm).

           - Each Coral bollard is supplied equipped with electric cables of 10 meters in length

             (for electric motor, limit switch, solenoid valve, leds).

A

500

600

800

B

330

C

ø 100

D

400

E

170

F

ø 195

G

850

960

1.140

H

1.350

1.560

1.940

Pic. 14

B

D

Cable

length

10 meters

E

F

A

A

G

H

C = 100

400 mm

100

30.000 J

150.000 J

62
53
43

28

24

19

Vehicle

MASS

 (kg)

Various  factors,  such  as  the  compaction  index,  soil  permeability 

coefficient and kind of concrete may reduce the values indicated in 

the diagram even signi cantly.

OVERALL DIMENSIONS AND DIAGRAM

fully retractable oil-hydraulic bollard

Содержание CORAL 1050

Страница 1: ...EN 13241 EN 12453 EN 12445 CORAL 1050 1063 1080 Instructions manual pages 1 16 the gate opener FULLY RETRACTABLE OIL HYDRAULIC BOLLARDS POST DIAMETER 100 mm HALL MAGNETIC LIMIT SWITCH GB...

Страница 2: ...ith a pedestrian entrance it is appropriate to prepare the system in such a way to prohibit the operation of the engine when the pedestrian entrance is used Apply safety nameplates with CE marking on...

Страница 3: ...erator can be introduced ready for operation as soon as the wiring has been completed As soon as the retractable post receives a command from a key switch or radio transmitter it rises from its interr...

Страница 4: ...tail of retractable post with hoisting connection PRELIMINARY OPENING OF ALL FUNCTIONAL COMPONENTS Start by removing the cover plate to reveal the operator and separate the individual components with...

Страница 5: ...res use electric cables with sections suited to the installation Pic 3 230V 50 Hz 1 2 3 4 5 6 6 7 2x1 mm 2x1 mm 3x1 mm 4x1 mm 4x1 mm 4x1 mm 8 10 11 8 9 1 Led ashing light with built in aerial 2 Stand...

Страница 6: ...Pic 4 Pic 5 IMPORTANT once the housing has been positioned and installation completed it is important for the top edge to be level with the ground Piping 5 cm for passage of electric wires Concrete c...

Страница 7: ...r inside the housing Pic 6 IMPORTANT PASS THE MOTOR LIMIT SWITCH SOLENOID VALVE AND LED POWER SUPPLY ELECTRIC WIRES THROUGH THE PIPING WITHOUT TEARING OR CUTTING THE CABLES Hoisting hook Oil hydraulic...

Страница 8: ...near the installation to prevent interference or any a ecting action with the magnetic loops of the vehicle detecting device if installed or with any other electronic equipment included in the system...

Страница 9: ...are properly alight the post should move up on the rst commanding pulse should it fail disconnect power supply and swap the connections to the live terminals NOTE WELL supply the system with electric...

Страница 10: ...GROUND LEVEL CLOSURE COVER PLATE Use the four screws to close the cover plate Lift the retractable post for facilitate closure of the post cover with the bu er give the command by encoding a transmit...

Страница 11: ...ds IP 67 A 40 C with speci c optional accessories Ref General Catalogue PERFORMANCE CORAL 1050 Frequency of use intensive Service cycle rise 4 7 s dwell 30 s lower 4 4 s dwell 30 s Complete cycle time...

Страница 12: ...lard to avoid that settling at a later stage causes problems to the system 5 Make sure the site is free from utilities that may interfere with it 6 Make sure that electromagnetic sources are at a suit...

Страница 13: ...CORAL 13 fully retractable oil hydraulic bollard...

Страница 14: ...14 CORAL fully retractable oil hydraulic bollard...

Страница 15: ...antity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation maintenance repairs and replacements to be made only by us...

Страница 16: ...extra capacitor to the existing one instructions manual is to be referred to Check the correct functioning of the signal LED lights if incorporated in the bollard head Sight check the electronic board...

Отзывы: