VENTING   REQUIREMENTS

Determine which venting method is best for your application.  

Ductwork can extend either through the wall or the roof.

The length of the ductwork and the number of elbows should 

be kept to a minimum to provide efficient performance.  The 

size of the ductwork should be uniform.  Do not install two 

elbows together.  Use duct tape to seal all joints in the ductwork 

system.  Use caulking to seal exterior wall or floor opening 

around the cap.

Flexible  ductwork  is  not  recommended.    If  it  is  used, 

each  foot  of  flexible  ductwork  used  is  equivalent  to 

two  feet  of  straight  metal  ductwork  when  calculating 

the ductrun length.  Thus, a flexible elbow equals two 

standard elbows.

Make sure there is proper clearance within the wall or floor 

for exhaust duct before making cutouts.  Do not cut a joist or 

stud unless absolutely necessary.  If a joist or stud must be 

cut, then a supporting frame must be constructed.

FOR MORE SPECIFIC DUCTWORK INFORMATION, GO 

TO PAGE 4.

WARNING - To Reduce The Risk Of Fire, Use Only Metal 

Ductwork.

ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz AC-only electrical supply is required on a 

separate 15 amp fused circuit.  A time-delay fuse or circuit 

breaker is recommended.  The fuse must be sized per local 

codes in accordance with the electrical rating of this unit as 

specified  on  the  serial/rating  plate  located  inside  the  unit 

near the field wiring compartment.  THIS UNIT MUST BE 

CONNECTED  WITH  COPPER  WIRE  ONLY.    Wire  sizes 

must conform to the requirements of the National Electrical 

Code, ANSI/NFPA 70 - latest edition, and all local codes and 

ordinances.  Wire size and connections must conform with the 

rating of the appliance.  Copies of the standard listed above 

may be obtained from: 

 

National Fire Protection Association

 

Batterymarch Park

 

Quincy, Massachusetts  02269

• Venting system MUST terminate outside the home.

• 

DO NOT

 terminate the ductwork in an attic or other 

enclosed space.

• 

DO NOT

 use 4" laundry-type wall caps.

• Flexible-type ductwork is not recommended.

• 

DO NOT

 obstruct the flow of combustion and 

ventilation air.

• Failure to follow venting requirements may result in 

a  fire.

This  appliance  should  be  connected  directly  to  the  fused 

disconnect (or circuit breaker) through flexible, armored or 

nonmetallic sheathed copper cable.  Allow some slack in the 

cable so the appliance can be moved if servicing is ever nec-

essary.  A UL Listed, 1/2" conduit connector must be provided 

at each end of the power supply cable (at the appliance and 

at the junction box). 

When making the electrical connection, cut a 1   1/4" hole 

in the wall.  A hole cut through wood must be sanded until 

smooth.  A hole through metal must have a grommet. 

WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC 

SHOCK, do not use this fan with any solid-state speed 

control device.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI-

CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE 

FOLLOWING:  Use this unit only in the manner intended 

by the manufacturer.  If you have any questions, contact 

the manufacturer.
Before servicing or cleaning unit, switch power off at 

service panel and lock the service disconnecting means 

to prevent power from being switched on accidentally.  

When the service disconnecting means cannot be locked, 

securely fasten a prominent warning device, such as a 

tag, to the service panel.
CAUTION:  For  General  Ventilating  Use  Only.    Do  Not 

Use To Exhaust Hazardous  or  Explosive Materials and 

Vapors.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI-

CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE 

FOLLOWING: Installation Work And Electrical Wiring Must 

Be Done By Qualified Person(s) In Accordance With All 

Applicable Codes And Standards, Including Fire-Rated 

Construction.  
Sufficient  air  is  needed  for  proper  combustion  and 

exhausting of gases through the flue (chimney) of fuel 

burning equipment to prevent backdrafting.  Follow the 

heating equipment manufacturer's guideline and safety 

standards such as those published by the National Fire 

Protection Association (NFPA), and the American Society 

for Heating, Refrigeration and Air Conditioning Engineers 

(ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling, do not dam-

age electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.

   WARNING

• Electrical ground is required on this rangehood.

• If cold water pipe is interrupted by plastic, 

nonmetallic gaskets or other materials, DO NOT 

use for grounding.

• DO NOT ground to a gas pipe.

• DO NOT have a fuse in the neutral or grounding 

circuit.  A fuse in the neutral or grounding circuit 

could result in electrical shock.

• Check with a qualified electrician if you are in doubt 

as to whether the rangehood is properly grounded. 

• Failure to follow electrical requirements may result 

in a fire.   

   WARNING

For residential use only.

!

!

Cold Weather installations

An additional back draft damper should be installed to minimize 

backward cold air flow and a nonmetallic thermal break should 

be installed to minimize conduction of outside temperatures 

as part of the vent system. The damper should be on the cold 

air side of the thermal break. The break should be as close as 

possible to where the vent system enters the heated portion 

of the house.

CAUTION: To reduce risk of fire and to properly exhaust air, be 

sure to duct air outside - do not vent exhuast air into spaces within 

walls or ceilings or into attics, crawl spaces or garages.

Содержание GLASSY

Страница 1: ...oth sides of this unit must be a minimum of 18 above the cooking surface or countertop Consult the cooktop or range installation instructions given by the manufacturer before making any cutouts LISEZ...

Страница 2: ...ll A hole cut through wood must be sanded until smooth A hole through metal must have a grommet WARNING TOREDUCETHERISKOFFIREORELECTRIC SHOCK do not use this fan with any solid state speed control dev...

Страница 3: ...ication avec lui pour toute information Fermez le courant avant tout entretien et veillez a ce qu il reste ferm Si on ne peut pas verrouiller le panneaux du service lectrique affichez un avis de dange...

Страница 4: ...upper chimney that came with hood Une chemin e sup rieure de 40 po HIGH1 OPTIONAL ACCESSORIES AVAILABLE AND DIMENSIONS ACCESSOIRES POUR L INSTALLATION dimensions d installatioN DIMENSIONS ACCESSORIES...

Страница 5: ...ows Makesurethatthereisaminimumof 24 of straight duct between elbows if more than one is used Do not install two elbows together If you must elbow right away do it asfarawayfromthehood sexhaustopening...

Страница 6: ...ts 5 For the most secure installation the MOUNTING SCREWS D in FIGURE 1 which mount the CANOPY SECTION Ain FIGURE 1 should be installed into wood Mark the wall along the horizontal line 4 9 16 in from...

Страница 7: ...he side vent holes on the top towards the ceiling or flip the chimney and hide the holes under the lower chimney Install the UPPER CHIMNEY COVER B in FIGURE 1 by slightly widening the two sides and ho...

Страница 8: ...hed in the dishwasher Stainless steel cleaner should be used on stainless rangehoods Abrasives and scouring agents can scratch stainless steel finishes and should not be used to clean finished surface...

Страница 9: ...ut tre actionn en appuyant sur les boutons l uns des de vitesse Bouton de vitesse du ventilateur V Commande de vitesse pour le ventilateur Pressez le de commutateur 1 pour vitesse r duite 2 pour la vi...

Страница 10: ...umbing 2 Service calls to repair or replace range hood light bulbs fuses or filters Those consumable parts are excluded from warranty coverage 3 Repairs when your range hood is used for other than nor...

Страница 11: ...ou sans conduit Pour une installation avec conduit la ventilation peut s effectuer par le mur ou le plafond Pour une ventilation par le mur un coude de 90 est utilis AVERTISSEMENT AVANT DE FAIRE UNE...

Страница 12: ...iqu dans X le SCH MA5 et installent les VIS de SUPPORT sur le mur partant au sujet de 1 4 entaillez entre le mur et la t te de la vis D terminez l endroit appropri pour chaque parenth se et installez...

Страница 13: ...esaccrochant derri re les SUPPORTS de CHEMIN E e Fixez les c t s aux SUPPORTS de CHEMIN E avec les 4 VIS G de CHEMIN E Installez la COUVERTURE INF RIEURE de CHEMIN E c en largissant l g rement les deu...

Страница 14: ...l acier inoxydable sur les hottes en acier inoxydable Ne pas utiliser de produits abrasifs ou de r curants car ils peuvent gratigner le fini en acier inoxydable et ils ne devraient pas tre employ s p...

Страница 15: ...les de votre maison ou pour corriger votre c blage ou votre syst me de plomberie 2 Les appels de service pour remplacer ou r parer les ampoules les fusibles ou les filtres de votre hotte de cuisini re...

Отзывы: