I n s t a l l a t i o n I n s t r u c t i o n s
1 1
Points to note for build-in and finishing:
A = installation reference markers (fig. 2.5)
S, T and Q = decorative frames (fig. 2.6)
If the reference markers are not removed, after installation the
decorative frames will not fit!
Always install the combustion air supply grilles in the false chimney
breast (fig. 1.1).
4.5
Mounting the decorative frames
•
First, install the bottom decorative frame piece (fig. 2.6 Q).
•
Then install the left and right decorative frame pieces
(fig. 2.6 S), these are held in place by the adjustable
magnetic snappers.
•
Now install and tighten the top frame (fig. 2.6 T)
4.6 4
Seasons Premium with mantelpiece
Keep in mind the build-in measurements and the minimum fireplace
opening measurement (see size drawing and fig. 2.5)
5 Checking the technical installation
5.1
Initial use of the fire
When using the fire for the first time, always use the remote control.
The unit must not be linked to the Wi-Fi and App.
Upon leaving the factory, the remote control is already linked to the
fireplace.
You must manually open and close the door before igniting the fire.
To this end, switch on the service mode switch (fig 1.2B and fig 1.8
I). The LED on the ITC will now start to flash in orange to indicate
that the fire is in service mode!
You can now open the door with the push-button (fig 1.2 H, fig
1.8L). Keep in mind that when the door opens for the first time, it
will open slowly. If you hear any strange noises, immediately stop
using the unit and determine the cause. After the door has fully
opened, press the push-button to close the door again (fig 1.2G, fig
1.8M). Then open the door again and install the decorative material
and the logs.
Now turn off the service mode switch.
See also user’s manual ITC 4Seasons Premium
If required, bleed the gas line!
5.2
Service mode
This function is only used for servicing purposes and in case the
window or door remains stuck in a certain position after a power
outage. You can close the door again when in service mode. The
fireplace will continue to work as usual again after leaving the
service mode.
For the operation of the service mode, see 5.1 initial use.
5.2.1
Placing the decoration material
It is not permitted to use other or to add more material in the
combustion chamber.
Always keep the ignition and ionisation pins clear of all
decorative material!
Do not pour all decorative material on to the burner at once; it can
get clogged because of dust particles.
5.2.1.1 Wood set
•
Place the ionisation cover (fig.4.1A)
•
Place some of the chips on the burner and on the bottom.
•
Places the wood blocks as prescribed. (Fig. 4.1 of included
wood set card)
•
Divide the rest of the chips on the burner and on the bottom.
Prevent a thick layer on the burner; this adversely affects the
fire image.
•
Manually close the window by pressing the push-button
(fig1.2G and fig 1.8M).
•
Now turn on the service mode switch again (fig1.2B and fig
1.8I)
5.2.2
Checking the ignition on the main burner and the
flame spread.
Start the ignition procedure according to the instructions in the
user’s manual.
If the burner fails after the first ignition procedure (15 seconds), you
must reset the electronics.
Reset: via the remote control
function button: 2+5 (fig4.2)
•
Always wait for 5 minutes before restarting the fireplace.
•
After a third reset, an automatic obstruction of 15
minutes is programmed; you can start the unit again
after these 15 minutes.
•
Check whether the ignition on the main burner occurs rapidly
and smoothly
•
The middle part of the main burner will automatically start to
burn on the middle (high flame) setting.
•
Use the remote control to switch the fireplace to the desired
setting.
•
Evaluate the flame spread by letting the fireplace work on
both wide and high flame settings.
TIP: You can move around some of the decorative material to
obtain the best flame spread.
5.2.3
Checking for gas leaks
Check with a gas leak finder or spray all connections and pipes for
gas leakage.
>
PLEASE NOTE: Make sure to dry all the components
checked with spray.
Содержание 4Seasons Premium
Страница 1: ...4Seasons Premium 40011600 1540 4Seasons Premium EN ...
Страница 3: ...I n s t a l l a t i o n I n s t r u c t i o n s 3 1 4 1 5 1 6 1 7 1 3 P2 P1 4x A 0 5 M MAX C B B A ...
Страница 6: ...I n s t a l l a t i o n I n s t r u c t i o n s 6 3 1 4 1 3 2 2 1 ...
Страница 13: ...1 3 8 Technical data I n s t a l l a t i o n I n s t r u c t i o n s ...
Страница 15: ...1 5 I n s t a l l a t i o n I n s t r u c t i o n s ...
Страница 16: ...1 6 www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen Dealerinfo ...