I n s t a l l a t i o n I n s t r u c t i o n s
8
1.3
CE Declaration
Glen Dimplex Benelux hereby declares that this Faber fire meets all
essential requirements of the Gas Appliances Directive.
Product: gas room heater
Model: 4Season Premium
Applicable EC Directives: 2009/142/EC
Harmonised standards applied:
NEN-EN-613:2000;NEN-EN-613/A1:2003; EN509:1999/A1:2003/
A2:2005
This Declaration is invalid, if without the written permission of Glen
Dimplex Benelux:
•
Changes are made to the appliance.
•
The fireplace is connected to flue gas discharge materials
other than those specified.
•
The fireplace is connected to a flue gas fan other than those
specified.
1.4
Operating principle of the device
The 4Seasons Premium is a gas fire belonging to the category B22.
It is a multifunctional fire suitable for use with both an open door or
a closed door.
When the Flue Gas Fan (fig.1.0) starts turning, the supply of
combustion air begins (fig.1.1A). The cold combustion air is
preheated through the convection chamber of the fire and this
preheated air is supported to the room through grilles B (fig. 1.1B).
Before being drawn in as combustion supply air through the pipes
and grilles D.(fig.1.1D) The combustion gasses will be discharged
through the flue gas outlet (fig. 1.1E).
1.4.1
Process description (fig 4.2)
1.4.1.1 Command: Starting the fireplace:
For initial use, always with the remote control. Do not link the
ITC to the App. For further start-up instructions, also refer to
5.1.
(remote control or via the ITC APP)
•
Fan starts turning
-
internal monitoring of safety systems.
-
With under pressure, within the correct operating range
the pressure switch will activate the operating system.
•
The pressure sensor measures the rotation speed of the fan
and feeds it back to the operating pressure of the system.
•
The ignition procedure takes 15 seconds and will ignite the
burner on medium high fire setting.
1. After a positive start, the flame effect can be adjusted
to the desired setting via the remote control or the ITC
App.
2. In case of a negative start (red flashing of the ITC and
on the remote control), a reset is required.
(combination buttons 2-5) (fig. 4.2)
>
PLEASE NOTE: After three reset attempts, the system
will be locked for 15 minutes, after which you can try
another start-up.
•
Continuous flame monitoring with ionisation safety.
1.4.1.2 Burner is on, Command: Opening the door (fig 4.2)
(only available via remote control)
•
The control system sends a command to the flue gas fan,
making it turn faster.
•
The door moves upwards and the flue gas outlet valve opens
simultaneously.
•
The pressure sensor measures the rotation speed of the fan
and feeds it back to the operating pressure of the system.
•
Continuous flame monitoring with ionisation safety.
>
PLEASE NOTE: When using the fire with the door open,
the door will close automatically after the following
commands:
1. Selecting the ECO mode
2. Selecting the Thermostat mode
3. Turning the fire off
•
After the fire is switched off, the flue gas fan will continue to
operate for another 10 minutes!
1.4.2
Mechanically ventilated environment
The 4Seasons Premium is provided with an electronic control
system, which can compensate for the under pressure in a
mechanically ventilated house to an under pressure of 15Pa.
2 Safety instructions
•
Do not leave the fireplace unattended with the door open.
•
Do not leave children near the fireplace unattended.
•
The entire installation must be installed and serviced annually
by a qualified engineer in accordance with these installation
instructions and the applicable national and local guidelines.
•
Check whether the data shown on the specification label
matches your local gas type and gas pressure.
•
The settings and the construction of the fire must not be
changed!
•
The mains lead may only be replaced by qualified personnel.
•
Do not place extra imitation wood or other material on the
burner or in the combustion chamber.
•
The unit is designed for atmosphere and heating purposes.
This means that all surfaces, including the glass, can be very
hot (over 100°C); exceptions to this are the bottom of the
fireplace and the control surfaces.
•
Keep flammable materials at least 1 m away from the
radiation zone of the fireplace.
•
When lightning the fire for the first time, run it for after several
hours on the highest setting, so that the paint can cure.
Provide adequate ventilation, so that any fumes can be
discharged.
We recommend that persons are present in the room as little
as possible during this process.
>
PLEASE NOTE: Through the natural air circulation of the
fire moisture and uncured volatile components from
paint, building materials and carpeted floors, etc. are
attracted. These parts can settle as soot on cold
surfaces. Therefore do not light the fire shortly after
installation.
2.1 Conversion from natural gas to propane (or vice versa)
The conversion to a different gas type may only be performed by a
qualified installer/dealer.
This can only be done by installing a correct burner unit. To do so,
please contact your dealer.
Specify with your order always the type and serial number of the
device.
Содержание 4Seasons Premium
Страница 1: ...4Seasons Premium 40011600 1540 4Seasons Premium EN ...
Страница 3: ...I n s t a l l a t i o n I n s t r u c t i o n s 3 1 4 1 5 1 6 1 7 1 3 P2 P1 4x A 0 5 M MAX C B B A ...
Страница 6: ...I n s t a l l a t i o n I n s t r u c t i o n s 6 3 1 4 1 3 2 2 1 ...
Страница 13: ...1 3 8 Technical data I n s t a l l a t i o n I n s t r u c t i o n s ...
Страница 15: ...1 5 I n s t a l l a t i o n I n s t r u c t i o n s ...
Страница 16: ...1 6 www faber nl info faber nl Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen Dealerinfo ...