XKPR 14
532192 - Rev.C
TECHNICAL DATA
power supply
SPINet Bus
MAX power consumption
90 mA
protection rating
IP 54
operating temperature
-20°C to +55°C
dimensions
100 x 72 x 26 mm
type of Tags recognised
125 kHz
L
L
Two devices can be installed on the SPINet Bus (reader A and B respectively).
2. XKPR
The XKPR reader is included in the FAAC range of access control devices.
The XKPR allows a tag to be read or numeric codes to be entered that are restricted to each user. In order
to be valid, each user code must be stored on the Door Controller.
!
- In order to restrict access, it is important not to allow the stored codes to be known by unau-
thorised persons. Whenever the user is given a code, one should recommend that he/she keeps
it confidential.
The XKPR must be connected to a DOOR Controller in order to work.
3. USAGE
!
The user must follow the safety instructions and recommendations given by the installer.
In order to restrict access, the user must not give his code to other people.
L
L
Always press one button at a time (if 2 buttons are pressed at the same time, neither is recogni-
sed). The timeout between the pressing one button and another is 5 s.
The installer must provide users with information for use.
Blind and Visually Impaired Users
: these users can recognise buttons using Braille.
Warnings
Green
Buzzer
Red
(OK)
1.0 s 2
(error)
1
0.5 s
To type in a code, enter the numbers that make up the code in sequence, pressing one key at time. When
finished press key
E
.
Pressing the
#
key will cancel the last digit that was entered.
EN