X 2
X 2
X 1
ENGLISH
13
PRESS THE UP OR DOWN PUSH-BUTTON AND TAKE THE AWINING TO THE
DOWN TRAVEL LIMIT
PRESS THE STOP/PREFERRED POSITION PUSH-BUTTON FOR 2 SECONDS. RELEASE IT FOR 1 SECOND AND HOLD IT
DOWN AGAIN TILL THE END OF THE INDICATED MOVEMENTS TO CONFIRM THE PERFORMED MEMORY STORING
OF THE UP TRAVEL LIMIT.
Every pressing
2 seconds
1 second
WITHIN 3 SECONDS
OR
DOWN
TRAVEL LIMIT
HOLD DOWN THE STOP/PREFERRED POSITION PUSH-BUTTON TILL THE INDICATED MOVEMENTS
5.3.2 SET-UP FOR STANDARD AWNINGS, SPRING-TYPE OR FALL-TYPE, STARTING FROM THE DOWN TRAVEL LIMIT
1) Press the up or down push-button and take the awning to the selected position for the DOWN travel limit. Release
the push- button.
2) Press the stop/preferred position push-button until the motor performs a brief movement in both directions.
3) Press the push-button controlling the rise and go to the up travel limit.
4) Press twice the stop/preferred position push-button . Release it for 1 second, and
hold it down again until the motor
performs a brief movement in both directions to confirm the correct setting of both the awning mode and the
up travel limit.
5) Check if the travel limit positions have been set correctly. If the travel limits have not been set correctly, execute a
reset and repeat the set-up procedure.
Содержание T-MODE TM 35 ER