manualshive.com logo in svg
background image

a

b

A

B

EN

g

L

iSH

5 INTERNAL MECHANICAL TRAVEL-LIMIT STOPS

 (POSITIVE STOP

)

The S800H operator is supplied standard with internal opening 
and closing mechanical stops. This is to facilitate the installation 
operations because there is no need to construct the mechanical 
stop elements. 
The mechanical travel-limit stops (POSITIVE STOP) can be adjusted 
in the last 30° of the operator’s MAXIMUM travel, at both opening 
and closing.
FAAC SUPPLIES THE TRAVEL LIMIT DEVICES TOTALLY OPEN ( MAXIMUM 
PINION ROTATION ANGLE ) , 

5.1  ADJUSTMENT OF THE TRAVEL-LIMIT STOPS

TRAVEL-LIMIT STOP 

AT OPENING

TRAVEL-LIMIT STOP AT CLOSING

1) Hydraulically release the operator. (See chpt 7.1)
2) Close the leaf, manually taking it into its closed position.
3) Unscrew the cap (Fig.23 ref.A) of the closing travel-limit screw 
(Fig.23 ref.

a

4) UNSCREW the travel-limit stop screw (Fig.25 ref.B) at closing 
(Fig.25 ref.

a

), until the leaf begins to move. 

5) Fasten the cap (Fig.23 ref.A) of the travel-limit stop screw.
6) Open the leaf, manually taking it into its opening position.
7) Unscrew the cap of the screw (Fig.23 ref.A) of the opening 
travel-limit stop (Fig.23 ref.

b

). 

8) UNSCREW the travel-limit stop screw (Fig.23 ref. 

b

), until the 

leaf begins to move.
9) Fasten the cap of the travel-limit stop screw.
10) Open and close the gate to check if the travel-limit stop is 
correctly adjusted.
11) Shut-down the operator again, following the instructions in 
chapter 7.1. 

CLOSING POSITION 

OPENING POSITION 

Fig.23

Fig.24

Fig.25

17)  Open  and  close  the  gate,  checking  and,  if  necessary, 
adjusting  the  respective  travel  limit  devices  as  described  in 
chapter 5.
18) As described in the instructions for the control unit, make the 
electrical connections, taking care over encoder polarity.
19) Hydraulically shut  down the operator as  per instructions  in 
chapter 7.1.

  BEFORE CARRYING OUT THE RELEASE AND SHUT-DOWN 

OPERATIONS, MAKE SURE THAT YOU HAVE CUT POWER 
TO THE OPERATOR AND THAT IT IS NOT MOVING

7  MANUAL OPERATION

6  FINAL OPERATIONS 

 

To  avoid  excessive  voltage  drops, 

we recommend that the length of 

the motor cables with a section of 

2.5 mm, should not exceed 20 m. 

The  maximum  total  length  of  the 

BUS  cables  must  not  exceed  100 

m.

1) Place the encoder in its seat on the motor.
2)  Connect  the  motor  (Fig.1  ref. 

h

)  and  the  encoder  (Fig.1  

ref. 

i

) to the control unit, following the specific instructions.

3) Secure the cover of the bearing case with the supplied screws 
(Fig.24;25).
4) Where specified by current legal regulations, place at least 
two signs with the words “Danger: Automatic motion” on both 
sides of the automated system.

www.metalines.com

[email protected]

Содержание S800H SB

Страница 1: ...S800H www metalines com sales metalines com...

Страница 2: ...in mm Cotas en mm Waarden in mm b d e f 480 270 249 a CASSETTA PORTANTE Bearing case CASSON PORTANT TRAGEGEH USE CAJA PORTANTE BEHUIZING a 270 480 A 228 B 249 B A 57 A A mm 26 47 c NEDERLANDS ESPA OL...

Страница 3: ...PARFAITEMENT ALIGN SUR L OP RATEUR Fig 7 ZUR GEW HRLEISTUNG EINER SACHGEM SSEN MONTAGE MUSS DIE DREHACHSE DES FL GELS PERFEKT ZUM ANTRIEB GEFLUCHTET SEIN Abb 7 PARA GARANTIZAR UNA CORRECTA INSTALACI N...

Страница 4: ...such as crushing dragging and shearing 17 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequately secured to the frame structure in addi...

Страница 5: ...operated release device p Wings for walling the bearing case q Hole for power cable or drain pipe r Release and adjustment key and supporting bush s Closing cover t Grooved bush 2 TECHNICAL SPECIFICAT...

Страница 6: ...rew Fig 3 ref a 3 On the operator unscrew the plug Fig 4 ref A of the screw of the closing travel limit device Fig 4 ref a and check if the screw is completely tight 4 Back off the closing travel limi...

Страница 7: ...screw the fastening screws with groover and washer as shown in Fig 10 ref C in order to secure the operator to the bearing case as shown in Fig 11 13 Open the gate and check if the opening travel limi...

Страница 8: ...upplied key in the gate closing direction as shown in Fig 14 up to the internal stop point of the piston and remove the key 4 2 OPERATOR WITH MECHANICAL RELEASE TRAVEL LIMIT STOP AT OPENING TRAVEL LIM...

Страница 9: ...released part freed from the gate remains in the gate closed position as shown in Fig 20 ref a 13 Raise the operator with its handles Fig 21 ref A inserting the pinion in the grooved bush in the beari...

Страница 10: ...to move 9 Fasten the cap of the travel limit stop screw 10 Open and close the gate to check if the travel limit stop is correctly adjusted 11 Shut down the operator again following the instructions i...

Страница 11: ...turn it clock wise sense up to its stop point 3 Pull the release lever toward you Fig 28 ref a 4 Move the leaf by hand Procedure for restoring the system to normal operation 1 Move the release lever...

Страница 12: ...opening cycle 5 Command the gate to close 6 While the leaf is moving loosen the closing bleed screw Fig 29 ref b 7 Using the bleed screw allow the air to come out from the hydraulic circuit until non...

Страница 13: ...ndbuch sind unverbindlich FAAC beh lt sich das Recht vor ohne die wesentlichen Eigenschaften dieses Ger tes zu ver ndern und ohne Verbindlichkeiten in Bezug auf die Neufassung der vorliegenden Anleitu...

Отзывы: