manualshive.com logo in svg
background image

SETTING

+

DL 1 DL 2 DL 3 DL 4 DL 5

J24

The internal battery charger must be disabled to use an external 
charger. To disable the battery charger unplug jumper J24

J24 PRESENT = BATTERY CHARGING ACTIVE
J24 NOT PRESENT = BATTERY CHARGING NOT ACTIVE

9.1  DISABLE THE BATTERY CHARGER

SETTING

+

DL 1 DL 2 DL 3 DL 4 DL 5

J24

1.  Disconnect the batteries if they are present.
2.  Turn the AC power off and insert the Flash Drive into the 

USB A input on the board

3.  Turn the AC power back on. The USB2 LED will start to flash to 

confirm the beginning of the software update. (WARNING: 
DON’T TURN THE POWER OFF OR REMOVE THE FLASH DRIVE 
UNTIL THE USB2 LED TURNS OFF. 

4.  Wait until the USB 2 LED turns off
5.  Remove the USB Flash drive.
6.  Cycle power, reconnect the batteries if needed and exe-

cute a new  SETUP procedure (See chapter 6)

For the upgrade you need a USB Flash Drive, where you have 
to copy the file supplied by FAAC. Then follow these steps:

WARNING: Only upgrade the firmware with the proper file 
supplied by FAAC, otherwise the board could be damaged

The E024U board keeps the operating firmware in a field pro-
grammable memory, it can be easily upgraded through the 
on board USB port

10. FIRMWARE UPGRADE

The E024U board allows the connection of a 24V backup 
battery to provide power to operate the gate during blackouts. 
For more details about how the boards handles the loss of 
main power and how to configure its behaviour please see 
par 4.3 and DS1 switch 7. 

To connect the battery use the provided cable and jumper. 
Plug the jumper from the red (+) terminal of first battery to the 
black (-) terminal on the second battery and then connect the 
battery cable red wire to the red (+) terminal on the second 
battery and the black wire to the black (-) terminal on the first 
battery. Finally plug the cable on the BATTERY connector on 
the board. 

SETTING

+

DL 1 DL 2 DL 3 DL 4 DL 5

J24

9.  BACKUP BATTERY

12VDC, 8 amp 

Battery 

12VDC, 8 amp 

Battery 

+

+

-

-

RED

BLACK 

JUMPER

A14

Содержание S418-LE

Страница 1: ...tor FAAC International Inc Headquarter East Coast Operations 3160 Murrell Rd Rockledge FL 32955 Tel 800 221 8278 www faacusa com FAAC International Inc West Coast Operations 357 South Acacia Avenue Fu...

Страница 2: ...SPECIFICATIONS 6 1 1 Dimensions 6 1 1 Technical Specifications 6 1 1 Electrical Setup 6 2 INSTALLATION 7 2 1 Preliminary Checks 7 2 2 Installation Dimensions 7 2 3 Installing The Operator 8 2 4 Wirin...

Страница 3: ...located within line of sight of the gate Activation of the reset control shall not cause the operator to start 7 All warning signs and placards must be installed and easily seen within visible proxim...

Страница 4: ...ystem component malfunctions disconnect the main power before attempting to repair it Do not impede the movement of the gate you may injure yourself or damage the gate system as a result This equipmen...

Страница 5: ...loading docks or other locations not intended to service the general public RESTRICTED ACCESS VEHICULAR GATE OPERATOR CLASS IV A vehicular gate operator system intended for use in guarded industrial l...

Страница 6: ...e leaf when the motor is not operating An easy to use release device allows to move the leaf in case of malfunction or a power outage The rear bracket is adjustable to gurantee maxi mum flexifility du...

Страница 7: ...racteristics The length of leaf must conform to what is shown in the technical specifications The structure of the leaves must be sturdy and rigid suitable for an automated system There must be regula...

Страница 8: ...f to 90 A B C To obtain opening of the leaf more than 90 A B C Lower A and B values produce higher peripheral leaf speeds Limit the difference between value A and value B to within 1 inches greater di...

Страница 9: ...in Fig 12 if the mechanical stop at closing is used or in Fig 13 if no mechanical stop at closing is used The operator could be temporarily powered with a 12Vdc battery to accomplish this 5 Secure the...

Страница 10: ...may be increased see Fig 4 up to a maximum of 4 inches using appropriate spacers placed between the front bracket and the gate s leaf 11 Make all the necessary corrections and repeat the procedures fr...

Страница 11: ...ig 22 5 Tighten the bolt The mechanical stop is coupled to a toothed section on the operator s body Fig 21 Ref 2 In case of difficulties moving the stop check that the coupling is free Do not force it...

Страница 12: ...rm several open close operations to check that the automated system works normally NOTE During the first cycle the operator might not slow down correctly Wait for the end of the cycle and then give th...

Страница 13: ...5 Harness Cover 16 60202215 Tensioning Set 17 60202225 Output Shaft 18 60202165 Bushing Part Part Number Description 19 718367 Pin With C Clip 20 60202355 Worm Gear Bushing 21 63001545 Screws 4 8x13mm...

Страница 14: ...supply Programming With trimmers dipswitches and pushbutton RADIO Connector for the radio receiver BATTERY Connector for the backup battery J24 Jumper to disable battery charging With the jumper prese...

Страница 15: ...negative for warning lamp DS1 SW12 OFF 24 Vdc negative for safety TX photocell monitored DS1 SW12 ON IMPORTANT for UL325 compliance the negative TX photocell option must be used 10 FCA 1 Open limit sw...

Страница 16: ...for protecting the area between the opening leaves and fixed obstacles walls etc against the risk of entrapment Closing Safety Devices Are active only during the gate closing movement and are suitable...

Страница 17: ...the gate opening and closing move ments and are suitable to protect the opening and closing areas against the risk of impact Typically these photocells work in combination with other monitored photoce...

Страница 18: ...one closes During the mo vement a command stops the gate AP Automatic step by step OFF ON ON 0 4 min One command opens waits for the pause time and then closes automatically A command during the pause...

Страница 19: ...USE TIME ADJUSTMENT 0 4 min Turn clockwise to increase the pause time TR6 CLOSING DELAY OF LEAF 1 OVER LEAF 2 ADJUSTMENT 0 15 sec Turn clockwise to increase the delay TR1 FORCE ADJUSTMENT MOTOR 1 Turn...

Страница 20: ...y With SW8 OFF the gate movement will be reversed as soon as the safety is active with SW8 ON the gate will stop when the safety is active and it will reverse only when the safety is deactivated again...

Страница 21: ...H S800H OFF OFF OFF S418 OFF OFF ON 415 390 770 ON OFF OFF DS 2 LOCK OUTPUT MODE OUTPUT MODE SW 4 Active only for 3 sec after an open impulse from gate closed OFF Active always except 3 sec before an...

Страница 22: ...B active OPEN B not active LED DL 16 STOP INPUT N C STOP non active STOP active or wiring error LED DL 17 FSW CL INPUT N C Closing safety devices clear Closing safety devices triggered or wiring error...

Страница 23: ...motor 1 or motor 2 error Verify the encoder wiring and LED status If they are correct replace the encoder Verify motor and encoder wire gauge are correct Verify operator is not on manual and hydrauli...

Страница 24: ...nd sensitivity using the trimmers 15 15 32 6 7 32 17 15 32 The E024U board is supplied on a panel that fits in a 16x14 enclosure 6 3 OBSTACLE DETECTION FUNCTION 7 ENCLOSURE 1 Apply resistance to the g...

Страница 25: ...llowing guidelines when installing the AC power 1 Check the local wiring codes in all cases and follow all local building codes Wiring and hookup should be performed by a qualified electrician install...

Страница 26: ...file supplied by FAAC Then follow these steps WARNING Only upgrade the firmware with the proper file supplied by FAAC otherwise the board could be damaged The E024U board keeps the operating firmware...

Страница 27: ...t release OPEN stops saves CLOSE OPEN recloses leaves immediately 1 recloses leaves immediately no effect OPEN CLOSE disabled no effect no effect CLOSE disabled no effect OPEN CLOSE disabled CLOSING r...

Страница 28: ...LOSE disabled recharges pause time CLOSE disabled CLOSING reopens leaves immediately reopens leaves immediately stops operation no effect reverses at opening see DS1 SW8 stops and opens at release OPE...

Страница 29: ...disabled no effect OPEN disabled no effect CLOSE disabled no effect OPEN CLOSE disabled LOGIC C CONTINUOS COMMANDS PULSES SYSTEM STATUS OPEN A OPEN B STOP FSW OP FSW CL FSW CL OP CLOSED opens the lea...

Страница 30: ...n subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or o...

Отзывы: