manualshive.com logo in svg
background image

A10

L

E

D

DESCRIPTION

LED STATUS 

In BOLD the normal state with gate closed and working

ON STEADY

OFF

BLINKING

1

LED BATTERY

Board working on AC 

power

Board working on

battery power or ext

supply

Battery charging

2

LED +24 

Main power present

Main power OFF

3

LED SET-UP

Normal operation

SLOW BLINK 

(1 sec. ON - 1 sec. OFF)

SET-UP needed 

FAST BLINK

(0.5 sec. ON - 0.5 sec OFF)

SET UP in in progress 

4

LED ERROR

Board malfunction.

See possible causes 

below

No errors

Error conditions. 

See LED ERROR DISPLAY table

5

LED BUS_MON

Communication  on  

Bus “2easy” OK

Communication bus 

“2Easy” inactive. Verify

the bus “2Easy” devices

for shorts

Bus 2Easy devices with the 

Same address. Verify dip switch

Setting on photocells or 

Encoder LEDs 

6

LED USB

Software update done

or USB key not present

USB key inserted and software

Update in progress 

(DON’T Remove the USB key)

7

RESERVED

  

 

8

LED   DL 14  

OPEN A INPUT (N.O.)

OPEN A active

OPEN A not active  

LED   DL 15

OPEN B INPUT (N.O.)

OPEN B  active

OPEN B not active  

LED   DL 16  

STOP INPUT (N.C.)

STOP non active

 STOP active or 

wiring error

LED   DL 17  

FSW CL INPUT (N.C.)

Closing safety 

devices clear

Closing safety devices

triggered or wiring error

LED   DL 18 

FSW OP INPUT (N.C.)

Opening safety

 devices clear

Opening safety devices

triggered or wiring error

9

LED DL 19 FCA1: OPEN

LIMIT SWITCH MOT1 (N.C.)

Limit switch

OFF or not used 

Limit Switch activated

LED DL 20 FCC1: CLOSE

LIMIT SWITCH MOT1 (N.C.)

Limit switch

OFF or not used 

Limit Switch activated

10

LED DL 21 FCA2: CLOSE

LIMIT SWITCH MOT2 (N.C.)

Limit switch

OFF or not used 

Limit Switch activated

LED DL 22 FCC2: CLOSE

LIMIT SWITCH MOT2 (N.C.)

Limit switch

OFF or not used 

Limit Switch activated

BOARD MALFUNCTION ERROR POSSIBLE CAUSES

SOLUTIONS

There were two consecutive obstacle detections (the audio alarm also should sound)

Remove obstructions

One of the motor driver components has failed

The board needs to be repaired

The idle current in one of the motors is out of range

Check the motors

Both limit switches are active at the same time

Check the limit switches

Input voltage from the power supply is out of range

Check DC input voltage

A10

Содержание S418-LE

Страница 1: ...tor FAAC International Inc Headquarter East Coast Operations 3160 Murrell Rd Rockledge FL 32955 Tel 800 221 8278 www faacusa com FAAC International Inc West Coast Operations 357 South Acacia Avenue Fu...

Страница 2: ...SPECIFICATIONS 6 1 1 Dimensions 6 1 1 Technical Specifications 6 1 1 Electrical Setup 6 2 INSTALLATION 7 2 1 Preliminary Checks 7 2 2 Installation Dimensions 7 2 3 Installing The Operator 8 2 4 Wirin...

Страница 3: ...located within line of sight of the gate Activation of the reset control shall not cause the operator to start 7 All warning signs and placards must be installed and easily seen within visible proxim...

Страница 4: ...ystem component malfunctions disconnect the main power before attempting to repair it Do not impede the movement of the gate you may injure yourself or damage the gate system as a result This equipmen...

Страница 5: ...loading docks or other locations not intended to service the general public RESTRICTED ACCESS VEHICULAR GATE OPERATOR CLASS IV A vehicular gate operator system intended for use in guarded industrial l...

Страница 6: ...e leaf when the motor is not operating An easy to use release device allows to move the leaf in case of malfunction or a power outage The rear bracket is adjustable to gurantee maxi mum flexifility du...

Страница 7: ...racteristics The length of leaf must conform to what is shown in the technical specifications The structure of the leaves must be sturdy and rigid suitable for an automated system There must be regula...

Страница 8: ...f to 90 A B C To obtain opening of the leaf more than 90 A B C Lower A and B values produce higher peripheral leaf speeds Limit the difference between value A and value B to within 1 inches greater di...

Страница 9: ...in Fig 12 if the mechanical stop at closing is used or in Fig 13 if no mechanical stop at closing is used The operator could be temporarily powered with a 12Vdc battery to accomplish this 5 Secure the...

Страница 10: ...may be increased see Fig 4 up to a maximum of 4 inches using appropriate spacers placed between the front bracket and the gate s leaf 11 Make all the necessary corrections and repeat the procedures fr...

Страница 11: ...ig 22 5 Tighten the bolt The mechanical stop is coupled to a toothed section on the operator s body Fig 21 Ref 2 In case of difficulties moving the stop check that the coupling is free Do not force it...

Страница 12: ...rm several open close operations to check that the automated system works normally NOTE During the first cycle the operator might not slow down correctly Wait for the end of the cycle and then give th...

Страница 13: ...5 Harness Cover 16 60202215 Tensioning Set 17 60202225 Output Shaft 18 60202165 Bushing Part Part Number Description 19 718367 Pin With C Clip 20 60202355 Worm Gear Bushing 21 63001545 Screws 4 8x13mm...

Страница 14: ...supply Programming With trimmers dipswitches and pushbutton RADIO Connector for the radio receiver BATTERY Connector for the backup battery J24 Jumper to disable battery charging With the jumper prese...

Страница 15: ...negative for warning lamp DS1 SW12 OFF 24 Vdc negative for safety TX photocell monitored DS1 SW12 ON IMPORTANT for UL325 compliance the negative TX photocell option must be used 10 FCA 1 Open limit sw...

Страница 16: ...for protecting the area between the opening leaves and fixed obstacles walls etc against the risk of entrapment Closing Safety Devices Are active only during the gate closing movement and are suitable...

Страница 17: ...the gate opening and closing move ments and are suitable to protect the opening and closing areas against the risk of impact Typically these photocells work in combination with other monitored photoce...

Страница 18: ...one closes During the mo vement a command stops the gate AP Automatic step by step OFF ON ON 0 4 min One command opens waits for the pause time and then closes automatically A command during the pause...

Страница 19: ...USE TIME ADJUSTMENT 0 4 min Turn clockwise to increase the pause time TR6 CLOSING DELAY OF LEAF 1 OVER LEAF 2 ADJUSTMENT 0 15 sec Turn clockwise to increase the delay TR1 FORCE ADJUSTMENT MOTOR 1 Turn...

Страница 20: ...y With SW8 OFF the gate movement will be reversed as soon as the safety is active with SW8 ON the gate will stop when the safety is active and it will reverse only when the safety is deactivated again...

Страница 21: ...H S800H OFF OFF OFF S418 OFF OFF ON 415 390 770 ON OFF OFF DS 2 LOCK OUTPUT MODE OUTPUT MODE SW 4 Active only for 3 sec after an open impulse from gate closed OFF Active always except 3 sec before an...

Страница 22: ...B active OPEN B not active LED DL 16 STOP INPUT N C STOP non active STOP active or wiring error LED DL 17 FSW CL INPUT N C Closing safety devices clear Closing safety devices triggered or wiring error...

Страница 23: ...motor 1 or motor 2 error Verify the encoder wiring and LED status If they are correct replace the encoder Verify motor and encoder wire gauge are correct Verify operator is not on manual and hydrauli...

Страница 24: ...nd sensitivity using the trimmers 15 15 32 6 7 32 17 15 32 The E024U board is supplied on a panel that fits in a 16x14 enclosure 6 3 OBSTACLE DETECTION FUNCTION 7 ENCLOSURE 1 Apply resistance to the g...

Страница 25: ...llowing guidelines when installing the AC power 1 Check the local wiring codes in all cases and follow all local building codes Wiring and hookup should be performed by a qualified electrician install...

Страница 26: ...file supplied by FAAC Then follow these steps WARNING Only upgrade the firmware with the proper file supplied by FAAC otherwise the board could be damaged The E024U board keeps the operating firmware...

Страница 27: ...t release OPEN stops saves CLOSE OPEN recloses leaves immediately 1 recloses leaves immediately no effect OPEN CLOSE disabled no effect no effect CLOSE disabled no effect OPEN CLOSE disabled CLOSING r...

Страница 28: ...LOSE disabled recharges pause time CLOSE disabled CLOSING reopens leaves immediately reopens leaves immediately stops operation no effect reverses at opening see DS1 SW8 stops and opens at release OPE...

Страница 29: ...disabled no effect OPEN disabled no effect CLOSE disabled no effect OPEN CLOSE disabled LOGIC C CONTINUOS COMMANDS PULSES SYSTEM STATUS OPEN A OPEN B STOP FSW OP FSW CL FSW CL OP CLOSED opens the lea...

Страница 30: ...n subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or o...

Отзывы: