1. DESCRIPTION
Thank you for choosing our product. FAAC is sure that it will give you all the performances you are looking for. All our products are the
result of a long experience in the field of the automated systems.
Thanks to its high powered microprocessor, this 24 V control unit for automatic barriers offers a wide range of adjustments, including
deceleration and motor control.
Thanks to its integrated encoder, the control unit constantly controls rod position and movement, intervening as soon as a faulty situation
is detected.
The
FAILSAFE
function makes it possible to detect any faults in the operation of the photocells.
The main operating modes and functions are set by a dip-switch, whereas the adjustment of work and pause times is done by self learning
during programming.
2. TECHNICAL SPECIFICATIONS
Power supply voltage
230 V~ (+6% -10%) 50 Hz / 115 V~ 60 Hz
Supply voltage of control unit
24 V~ nominal
a
Absorbed power
3 W
Motor nominal power
48 W
Accessories max. load
500 mA
Flashing lamp max. load
15 W
Max. load for beam lights
15 W
Max. load for courtesy light/indicator light
5 W
Operating ambient temperature
-20°C +55°C
Protective fuse
F1=8 A F2=500 mA F3=630 mA (resettable)
Function logics
Automatic - Condo - Manual
Opening / closing time
Through self-learning during programming
Pause time
Through self-learning during programming
Obstacle detection
Trimmer-adjustable
Selectable functions
Type of logic - Operation of open command - No mains power supplied
function - Beam lights flashing - Safety devices behaviour
Terminal board inputs
Power supply - Earth - Close - Open - Open/Close - Stop - Safety
devices - FAILSAFE
Inputs with connector
Battery kit - Radio connector
Terminal board outputs
Power supply for accessories - On beam lights - Indicator light - Flash-
light
Board dimensions
79 x 158 mm
Characteristics of optional batteries
See kit on price list
a
According to mains voltage, there may be different output values on the board power feed terminals. Before putting into
service, always check if the output voltage on the secondary winding of the transformer is from 20 V~ to 26 V~. Voltage
must always be measured load free.
3. PREPARATIONS
To ensure people’s safety, all warnings and instructions in this booklet must be carefully observed. Incorrect installation
or incorrect use of the product could cause serious harm to people.
Make sure that an adequate differential switch is installed upstream of the system as specified by current regulations.
On the main power supply, install a thermal breaker with omnipolar switching.
Make sure that an adequate earthing system is available.
To lay cables, use adequate rigid and/or flexible tubes.
Always separate the connecting cables of low voltage accessories from those supplying 230/115 V~, using separate sheaths to avoid
possible interference.
4. BOARD LAY-OUT (Fig. 1)
COMPONENTS
COMPONENTS
CN1
Power supply terminal-board
P
OPEN/CLOSE channel memory storage push-button
CN2
Commands terminal-board
F1
Board protection fuse
JP2
Battery kit connector
DL1
CLOSE contact LED
JP
Connector for receiver module
DL2
OPEN contact LED
JP4
Power supply to RH closing motor
DL
OPEN/CLOSE contact LED
JP5
Power supply to LH closing motor
DL4
STOP contact LED
TR1
Trimmer for adjusting obstacle detection sensitivity
DL5
Photocells status LED
P1
Programming push-button
DL6
OPEN contact signalling LED
P2
OPEN channel memory storage push-button
DL7
OPEN/CLOSE contact signalling LED
•
•
•
•
•