Tr

ansla

tion of the original instruc

tions

ENGLISH

Available if the SDK EVO is connected to the board 

ID

=1. Displays the 

NODES

 that have 

been registered and the relative information for each one:
 

INFO

ERRORS

WARNINGS

CYCLES NUMBER

MAINTENANCE

.

MAINTENANCE

 allows the 

NODE

 to be set to 

MANUAL

 or 

LOCAL

. Selecting 

DISABLED

 

restores the 

NODE

 in 

INTERCOM

 (§ Section INTERCOM).

 

10 MISCELLANEOUS

CONFIG. DEFAULT

 ACTIVE

 = the programming corresponds to the 

DEFAULT

 settings

 NO

 = the programming does not correspond to the 

DEFAULT

 settings  Press OK to 

reload the 

DEFAULT

 settings.  The following question appears:

 

DO YOU WANT TO RELOAD DEFAULT CONFIG?

  Press OK to confirm.

PARTIAL OPEN 

(NOT for SF1400 and GBF1500)

Defines the opening percentage in 

PARTIAL OPEN

 mode:  20…100%

BOARD'S DISPLAY

Allows programming from the board to be enabled/disabled.

 NOT BLOCKED

  programming from the board is enabled

 BLOCKED

 disabled

OP.SAFETY FUNC.

Defines the way one or more inputs configured as an 

OPENING SAFETY

 operate.

  Low Energy  carries out movement at low speed

 STOP

  stops the automation

INTRUSION

Defines the operation in response to an attempt to open the automation manually.
 

DISABLED

  does not actuate the motor

  KEEP CLOSED  actuates the motor in order to keep closed
  PULL & GO  the motor completes the opening  (NOT active with battery operation) 

PARTIAL PHARMACY 

(NOT for SF1400 and GBF1500)

It defines the opening percentage of the 

PHARMACY OPEN

 command in 

NIGHT-TIME

 

mode): 1…95%

SDK EVO 

KEY

Defines the operation of a key switch connected to the SDK EVO:

 BLOCK

  SDK EVO works with password when the contact is open and is locked when 

the contact is closed.
 

WITHOUT USER PSW

  SDK EVO works without a password when the contact is open 

and with a password when the contact is closed (* is indicated on the HOME PAGE)

CONSECUTIVE OBST.

Defines the number of consecutive obstacle detections after which the automation 
stops in an error state.
 

CLOSING

  no…10  (no = no count)

 

OPENING

  no…10  (no = no count)

TEST ERROR

Allows the movement to be activated in Low Energy mode (as opposed to movement 
inhibited) if there is a 

TEST ERROR

 on an input configured as 

SAFETY

.

 

ENABLED

 = movement inhibited

 

DISABLED

 = movement in Low Energy mode

BACKLIGHT DISPLAY

Allows the backlighting of the SDK EVO to be enabled/disabled.
 

ALWAYS

  Backlighting is always active.

 

DISABLED

  The backlighting is activated when the buttons are pressed (it turns off 

after 2 min if no buttons are pressed).

ELASTIC KIT 

(NOT for SF1400 and GBF1500)

Allows the elastic anti-panic kit to be enabled/disabled. 

ENABLED

DISABLED

MENU 3 ERRORS

The display shows current errors (§ Diagnostics Section).

MENU 4 INDICATIONS

The display shows current alerts (§ Diagnostics Section). 

 MENU 5 CYCLE COUNTER

 

CYCLES NUMBER

The display shows the number of cycles performed: 

ABSOLUTE

 

RELATIVE

 

MAINTENANCE

Technician PSW required.  Allows the maintenance request to be specified when a 
number of cycles has been reached.  If a date is also entered, a maintenance request 
is made when the first event is reached: cycles or date.

 MAINTENANCE CYCLES

 1000…1000000  counting the 

RELATIVE

 cycles

 DATE

  optional  00/00/00 = disabled

 

CYCLES RESET

Technician PSW required.  It resets the 

RELATIVE

 cycle counter to zero.  This command 

requires confirmation  The 

ABSOLUTE

 cycles counter can only be reset using the restore 

factory defaults procedure (relative § Section).

MENU 6 DATE / TIME

 

SET DATE

Set date in dd/mm/yy.

 

SET TIME

Set time in HH:mm.

 

EUROPEAN DAYLIGHT SAVING TIME

Allows the European summer (daylight savings) time to be updated automatically.

MENU 7 

TIMER

Refer to the § 

TIMER

 Section.

Programming allows the operating mode to be set for the required 

TIME SLOTS

 for one 

or more days of the week.  Set any 

JOLLY

 slots that may be required. When the 

TIMER

 

is active, the operating mode is set automatically according to the set time bands and 
the warning T appears on the HOME PAGE. To change the operating mode manually 
that was activated by the 

TIMER

, it must be disabled.

 

TIMER

 STATUS

Allows the 

TIMER

 to be enabled/disabled: 

ENABLED

DISABLED

 (the programming 

carried out remains in memory but is not executed).

 

 2 MONDAY... 8 SUNDAY

Allows the days of the week to be programmed:  select the day, select the 

TIME SLOT

assign the operating mode and set the 

BEGINNING

 and the 

END

 time of the 

TIME 

SLOT

.  Carry out the same procedure for the other 

TIME SLOTS

 required.

 

 9 MON-SUN, 10 MON-FRI

Allows groups of days to be programmed quickly with the same 

TIME SLOTS

: select a 

group of days (from 

MON-SUN

 or from 

MON-FRI

). Select the 

TIME SLOT

, set the 

BEGIN-

NING

 and 

END 

time and assign the operating mode.  Carry out the same procedure 

for the other 

TIME SLOTS

 required.  Apply the programming to the group of days by 

selecting 

APPLY

; any settings already made for individual days will be overwritten.

 

 11 

JOLLY

Allows the operation of the 

TIMER

 to be set in the 

JOLLY

 slots (one or more days that 

require a different programming):  program the required 

JOLLY

 

TIME SLOTS

 (operating 

mode and the 

BEGINNING

 and 

END

) time.

 

12 

JOLLY SLOTS

To apply the 

JOLLY

 programming to individual days or to 

SLOTS

 of multiple days:  enable 

SLOT

, specify the 

BEGINNING

 and 

END

 date for the 

SLOT

.  Carry out the same procedure 

for the other 

INTERVALS

 required.

Содержание E1SL

Страница 1: ...E1SL SDK EVO LK EVO KS EVO E1SL FW 3 4 SDK EVO FW 3 4 LK EVO FW 1 3 KS EVO FW 1 0 This document contains updated instructions starting from the FW versions indicated EN...

Страница 2: ...leurs fabricants respectifs Les clients peuvent faire des copies pour leur usage exclusif Ce manuel a t publi en 2018 Copyright FAAC S p A ab dem 2018 Alle Rechte vorbehalten Kein Teil dieses Handbuch...

Страница 3: ...ow Energy 20 7 8 Intrusion 20 KEEP CLOSED 20 PULL GO 20 7 9 Energy Saving 20 7 10 Timing and partial opening 20 7 11 Date andTime 21 7 12 Cycle counter Scheduled maintenance 21 7 13 TIMER 22 WEEKLY PR...

Страница 4: ...ssory protection 2 A F quick F3 power supply unit primary protection 2 5 AT delayed 5x20 mm BOARD E1SL DO NOT remove this cover Buttons SW1 SETUP RESET SW2 scrolls programming values SW3 scrolls progr...

Страница 5: ...N USB storage device ERR RED error or warning BAT1 RED battery status BAT2 GREEN battery charger status SIC_OP RED safety in opening SIC_OP and SIC_CL lit simultaneously safety STOP SIC_CL RED safety...

Страница 6: ...usingthescrewsprovided 7 Insertthe 2combconnectorsintotheconnectorsoftheE1SLboardasfaras the connector 8 Insert the DM board 9 on the side opposite the comb connectors as far as the connector 8 Fasten...

Страница 7: ...6 7 E1SL 7 53225804 Rev B 6 8 7 10 9 12 11 Translation of the original instructions ENGLISH red black Installing the DM board 2nd MOTOR connection...

Страница 8: ...he leaves can be moved safely When you exit from MANUAL mode the board will carry out a RESET OPEN mode The automation opens and remains open NIGHT TIME mode The automation closes and remains closed E...

Страница 9: ...to the board 24V must not exceed 1A except SDK EVO 1 The motor M1 must be connected to connector J11 2 The encoder must be connected to connector J12 3 ADMboardmustbeinstalledonautomationsfittedwitha...

Страница 10: ...relative Section PROGRAMMING For the available options see Programming configurable Inputs andthefollowingsections Theinputisactivatedaccordingtohow thecontactlogicisprogrammed NO theinputactivateswh...

Страница 11: ...OP themovementstopsuntilthesafetyinopeningisdisengaged it then continues to open Low Energy the movement slows down until fully open from Board Advanced Programming Ot 1 STOP 2 Low Energy from SDK EVO...

Страница 12: ...h TEST enabled DOOR NOT CLOSED 6 indicates that the automation is NOT closed DOOR OPEN 7 indicates that the automation is open DOOR MOVING 8 indicates that the automation is moving LIGHT 9 switchesont...

Страница 13: ...ing modes with all the devices installed control devices safety detectors functionselectorsanddevicesconnectedtotheinputs and outputs For doors in Low Energy mode make sure that the forces gener ated...

Страница 14: ...press and hold the SW1 button for approximately 5 s until LO appears on the display from SDK EVO PROGRAMMING INSTALLATION START SETUP OK 4 The display shows the phases of the SETUP L0 L2 and the statu...

Страница 15: ...tton to modify it 4 PressbuttonFtoconfirmandgotothenextfunction Themodi fied value becomes effective immediately Follow the same procedure for all functions until you reach the last one St 5 WhenSt ap...

Страница 16: ...65 75 cm with 1 leaf 130 150 cm with 2 leaves 3 wide opening width greater than 75 cm with 1 leaf greater than 150 cm with 2 leaves 2 rM Direction of rotation of the motor If it is modified you have t...

Страница 17: ...enabled no TEST not enabled no no no no no C2 INPUT I2 configuration see options C1 4 4 4 4 4 2F INPUT I2TEST Displayed only if the input is configured as Safety C2 20 or 21 or 23 Y TEST enabled no T...

Страница 18: ...no TEST not enabled no no no no no bA BATTERY KIT Operation of the emergency battery NOT in NIGHT TIME mode no not enabled 1 OPENS immediately 2 CLOSES immediately 3 with flat battery last movement OP...

Страница 19: ...T NO 10 INTRUSION ACTIVE NO 11 CLOSING SAFETY NO 12 SAFETIES NO 13 AIRSLIDE SP1 NO 14 AIRSLIDE SP2 NO 15 LOCK NO o2 OUTPUT OUT2 configuration J22 see options o1 2 2 2 2 2 In Inputs status The segments...

Страница 20: ...not exceed 67 N Alternatively for doors that open onto heavy traffic areas or when any contact with the user is unacceptable because many of the users are elderly sick disabled or children additional...

Страница 21: ...ISABLED 7 12 CYCLE COUNTER SCHEDULED MAINTENANCE SDK EVO allows the ABSOLUTE and RELATIVE cycle counters to be managed and to program the maintenance request based on the number of cycles carried out...

Страница 22: ...s DONOTpro gram overlapping time bands Complete the weekly programming for all the required days JOLLY PROGRAMMING Program the JOLLY time bands The JOLLY programming must be applied to the dates speci...

Страница 23: ...d in MANUAL mode If there is a power failure the position of the XB LOCK remains un changed When the automation is operating on battery the motor block is only active in NIGHT mode operation can only...

Страница 24: ...NCTION SURVEILLANCE KIT BATT FUNCTION MOTOR BLOCK FUNCTION DISABLED EL 0 not active NIGHT EL 6 with the automation in NIGHT mode locks the closed leaves and the open leaves with the Pharmacy Open comm...

Страница 25: ...or safety Use the XV1 or XDT1 exit and entry detector in compliance with EN 16005 2012 and DIN18650 The defaultprogrammingoftheE1SL corresponds to the typical example configuration shown in the figure...

Страница 26: ...th persons is not allowed TheXDT1dualtechnologydetectorsallowradardetectiontobeused foropeningandinfrareddetectiontobeusedforsafety Install2entry and 2 exit radar detectors to cover large accesses in...

Страница 27: ...ns of safety detectors TheXBFAONinfrareddetectorsallowsafetyinopeningincompliance with EN 16005 2012 and DIN18650 The defaultprogrammingoftheE1SL corresponds to the typical example configuration shown...

Страница 28: ...lsareconsideredasauxiliarydevices complementarytosafety Button photocells are monitored by the electronic board which controls correct operation at each movement 1 Connect the photocells CABLE colour...

Страница 29: ...IRSLIDE an automation with an AIRSLIDE device INSTALLING INTERCOM 1 Connect all the boards together using 3 wires in a cascade con figuration in any order to the dedicated connectors 2 Connect the SDK...

Страница 30: ...accesses are closed again Use one direction radar detectors see relative section INTERLOCK is not available on E1RD boards INTERLOCK can be with or without memory INTERLOCKWITH NO MEMORY OPEN detecto...

Страница 31: ...2 02 DOOR NOT CLOSED 6 with contact logic NORMALLY OPENED 01 CLOSING SAFETY 11 with contact logic NORMALLY OPENED 4 OnAIRSLIDE assignthepre setIDusingtheDIPswitchesonboard E1AS follow the instructions...

Страница 32: ...ed IDs the EMERG inputs only activate the board that is connected E g EMERG OPEN connected to ID2 for the emergency opening of ID2 only MODFUN input The MODFUN is set on the MASTER ID1 TIMER input The...

Страница 33: ...lit To display the error code press the and buttons simultane ously The errors are described in the Diagnostics Section Press F to return to the menu When finished remove the USB storage device Downlo...

Страница 34: ...r USB GREEN USB storage device device present device not present ERR RED Error Warning in progress error no error warning warning BAT1 RED Battery status battery discharged battery charged battery in...

Страница 35: ...s See ErrorsandWarnings Iftherearemultipleerrorsatthesametime theonethat has priority is displayed The display is updated after it has been resolved from SDK EVO ERRORS WARNINGS FW VERSIONS The FW ver...

Страница 36: ...device 19 HIGH MECHANICAL FRICTION AUTORESET Check the leaves slide smoothly with power supply battery and motors disconnected Remove any fric tion Check the counter wheel 20 TESTonInputsconfiguredas...

Страница 37: ...ery has a low charge level 71 INTERCOM The automation is in INTERCOM mode 72 INTERCOM FAULT No communication between the Master and Slave nodes 73 INTERLOCK FUNCTION ACTIVE The automation is in INTERL...

Страница 38: ...Incorrect Opening Position RESET the board If the error persists replace the board 218 OBSTACLE DM Check for obstacles 219 BOARD ID ERROR Replace the board 220 BOARD POWER SUPPLY FAULT DM RESET the bo...

Страница 39: ...activated Check the motor connection Make sure that the motor block is not blocked Check presence of motor power supply voltage The door DOES NOT OPEN The safeties in opening are busy The emergencies...

Страница 40: ...ive operating mode remains on If the LEDs are both lit at the same time it indicates that the automation is in an operating mode that is NOT available on the KS EVO OPERATION To select the operating m...

Страница 41: ...e 27 Motor rotation error 29 DM board fault 30 Serious error 32 Motor time out 38 Configuration error 39 SETUP data missing or corrupted 99 Total deletion of board data LK EVO LOCK DEVICE The lock dev...

Страница 42: ...ve and Common contacts TX Data transmission RX Data reception V 24V accessories power supply usea4twistedpairU UTPAWG24cablewithamaximumlength of 50 m 5 Assemble the parts and fix it in place with the...

Страница 43: ...the cable knockout 2 3 Mark the points 3 on the wall and fasten the support using suitable screws F Before connecting the device disconnect the mains power supply and the emergency battery of the auto...

Страница 44: ...pears After a series of screens it reverts to the HOME PAGE PASSWORD PSW When the PASSWORD screen appears a 4 digit password must be entered There are 2 passwords USER PSW and TECHNICIAN PSW By defaul...

Страница 45: ...ctions using the buttons LANGUAGE PROGRAMMING TECHNICIAN PSW required ERRORS WARNINGS INTERCOM only available on the MASTER board specified in PROGRAMMING INTERCOM CYCLES COUNT DATE TIME TIMER PASSWOR...

Страница 46: ...O FRAN AIS ESPANOL SVENSKA PROGRAMMING LANGUAGE ERRORS WARNINGS CYCLES COUNT DATE TIME TIMER PASSWORD INFO 1 LANGUAGE 2 PROGRAMMING 3 ERRORS 4 WARNINGS 5 CYCLES COUNT MAINTENANCE CYCLES NUMBER CYCLES...

Страница 47: ...NT MOTION INPUTS OUTPUTS TIMING ENERGY SAVING BATTERY KIT KIT LOCK 2 PROGRAMMING INSTALLATION MISCELLANEOUS OUTPUTS O1 O2 MOTOR ROT INPUTS I1 I4 INPUTS STATUS INPUTS S1 S2 DOOR STATUS OTHER BOARD DATA...

Страница 48: ...led relative Section ENABLED DISABLED AIRSLIDE Allows AIRSLIDE to be enabled relative Section ENABLED DISABLED NODES ENTRY This is available if the SDK EVO is connected to the board ID 1 and allows al...

Страница 49: ...SF1400 and GBF1500 Allows the elastic anti panic kit to be enabled disabled ENABLED DISABLED MENU 3 ERRORS The display shows current errors Diagnostics Section MENU 4 INDICATIONS The display shows cu...

Страница 50: ...ws theTECHNICIAN PSW to be modified Enter the currentTECHNICIAN PSW then the new NEW PSW and press OK Re enter theNEWPSWandconfirmwithOK IfthePSWisnotrepeatedcorrectly theSDKEVO continues to request c...