9
10
E1SL
14
532258 04 - Rev. B
0.0
RESET/SETUP
DL2
+
-
F
J
L0...L1...L2
5 s
SW1
SETUP
/
RESET
L0
L0
0.0
RESET/SETUP
DL2
+
-
F
J
3.4
3.4
5 s
+
+
-
F
F
--
Tr
ansla
tion of the original instruc
tions
ENGLISH
7.2
SETUP
The board acquires the movement space of the leaves via the
SETUP
.
WHEN IS
SETUP
NECESSARY?
-
when the automation is first put into operation or after replac-
ing the board
-
after a change in the model of the automation, or the direction of
rotation of the motor, or the DM KIT has been enabled/disabled
-
following any travel variation
-
following a change in the number of leaves or the passage open-
ing for the SF1400
-
after a reset to factory settings
-
when the display indicates error
39
Impediments to
SETUP
The following are reasons for the
SETUP
proce-
dure NOT being carried out or being interrupted
(
error
15
):
-
emergency inputs active
-
MANUAL mode selected
-
NIGHT-TIME operating mode
-
the automation is operating on the battery, as there is no mains
power.
Activation of the safeties does not prevent
SETUP
from being per-
formed
PERFORM
SETUP
!
The inputs configured as safeties are ignored during
SETUP
. To prevent
any hindrance to motion, keep at a distance and prevent anyone from
going near the system.
1. Make sure that there is nothing that can prevent the
SETUP
pro-
cedure from being carried out and that the correct automation
model has been set.
2. Bring the leaf to its halfway position.
3. Start the
SETUP
procedure:
-
from board
: press and hold the SW1 button for approximately 5 s, until
LO
appears on the display
-
from SDK EVO
:
/
PROGRAMMING
/
INSTALLATION
/
START SETUP OK
4. The display shows the phases of the
SETUP
(
L0
…
L2
) and the
status of the automation when it has been completed.
If at the start of the
SETUP
procedure, the automation OPENS instead
of CLOSING, reverse the direction of rotation of the motor:
-
from board
Basic programming:
rM
-
from SDK EVO
:
/
PROGRAMMING
/
INSTALLATION
/
MOTOR ROTATION
select
STANDARD
or
NON STANDARD
SETUP
from board
LO
start
SETUP
L1
close the automation
L2
open the automation
Restoring factory settings
within 4 s of switching on
7.3 RESTORING FACTORY SETTINGS
The procedure:
-
deletes the
SETUP
data, the board LOG files and any TIMER
programming
-
restores all the programming defaults, including the model of
the automation
-
resets the cycle counters
-
causes the time and date to be lost
-
restores the default password (0000)
1. Turn off the mains power supply and disconnect the emergency
battery (if present), then turn the mains power back on.
2. Within the first 4 s after switching on (while the display is show-
ing the FW version), press the
+
-
F
F
buttons simultaneously for
about 5 s
-
The display indicates
--
3. Release the buttons: the display will indicate the status of the
automation.
After restoring the factory settings, carry out the set-up procedure
again.
To restore programming defaults ONLY:
-
from board
Basic programming:
dF
select
Y
-
from SDK EVO
:
/
PROGRAMMING
/
MISCELLANEUS
/
CONFIG. DEFAULT
select
OK
if
NO
appears, select
OK
the following question appears:
…
DO YOU WANT TO LOAD DEFAULT CONFIG ?
select
OK
or
ESC
Содержание E1SL