6. Press
F
to confirm and close the program. It returns to the
automation status view.
To
EXIT from programming mode at any
time
:
press and hold down
F
and then
-
as well, to
go directly to
St
.
F
+
-
8
Basic programming
Basic function
Default
dF
DEFAULT
Displayed if the board is configured with the
factory settings (default).
Y
indicates that all set values correspond to
the defaults
no
indicates that one or more set values are
different from the defaults
Select
Y
if you wish to restore the default
configuration.
Y
Ct
MASTER/SLAVE CONFIGURATION
MA
Configures the board in MASTER mode
SL
Configures the board in SLAVE mode
Some parameters will not be dis-
played if the board is configured to
work in SLAVE mode.
MA
LO
OPERATING LOGICS
E
Semi-automatic
A
Automatic
b
Semi-automatic
“b”
C
Person
present
For an explanation of the logics,
please see the specific section.
E
PA
PAUSE TIME A (displayed only if an automatic
logic is selected)
It is the total opening pause time.
Adjustable from
00
to
59
sec, in 1 second steps.
If 59 is exceeded, the display changes to indicate
minutes and tens of seconds (separated by a point)
and can be adjusted in steps of 10 seconds, up to a
maximum of 9.5 minutes.
E.g. If the display indicates
2.5
, the
time is 2 min. and 50 sec.
20
Basic function
Default
Pb
PAUSE TIME B (displayed only if an automatic
logic is selected)
It is the partial opening pause time.
Adjustable from
00
to
59
sec, in 1 second steps.
If 59 is exceeded, the display changes to indicate
minutes and tens of seconds (separated by a point)
and can be adjusted in steps of 10 seconds, up to a
maximum of 9.5 minutes.
E.g. If the display indicates
2.5
, the
time is 2 min. and 50 sec.
20
FO
MOTOR POWER
01
minimum
power
50
maximum
power
50
So
OPENING SPEED
01
minimum
speed
10
maximum
speed
08
Sc
CLOSING SPEED
01
minimum
speed
10
maximum
speed
08
ro
DECELERATION DURING OPENING
Regulates the gate deceleration space.
The deceleration space is set to 500 mm. The space
can be increased in steps of 1% of the remaining
stroke.
00
additional deceleration disabled
01-99
additional deceleration enabled
00
rc
DECELERATION DURING CLOSING
Regulates the gate deceleration space.
The deceleration space is set to 500 mm. The space
can be increased in steps of 1% of the remaining
stroke.
00
additional deceleration disabled
01-99
additional deceleration enabled
00
Sr
DECELERATION SPEED
01
LOW
speed
10
HIGH
speed
07
dl
OPENING DIRECTION
The opening direction is determined by looking at
the gate from the door side of the column.
-3
opens towards the right
E-
opens towards the left
bu
BUS 2easy DEVICE REGISTRATION
See the relative section.
no
M1
Dead-man MOTOR OPERATION mode
+
OPENS
(displaying
o P
) as long as the
button remains pressed.
-
CLOSES
(displaying
c L
) as long as the
button remains pressed.
--