![FAAC B614 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/faac/b614/b614_manual_3110034031.webp)
B614
29
532297 - Rev.D
5. ELECTRONIC INSTALLATION
F
ALWAYS DISCONNECT THE POWER SUPPLY before
working on the board. Turn power on only after
having made all the electrical connections and carried
out the preliminary start-up checks.
The board cover must never be removed unless the
board is to be replaced. No installation operation
requires the removal of the cover.
5.1 BOARD E614
4
E614 board technical data
Power supply voltage
115V~ +/-10% 50/60 Hz
Max power
150 W
Accessories output voltage
24 V
"
Max. accessories load
500 mA
Max. BUS 2easy accessories load
500 mA
Max. flashing light load
24 V
"
15 W
Ambient operating temperature
-4 ° to +131 °F (-20 °C to +55 °C)
COMPONENTS
See figure
30
BOARD:
J1
Mains power supply terminal block
J3
BUS 2easy terminal block
J6
Inputs terminal block
J7
Connector for XF radio module
J8
Connector for battery backup
J10
Terminal block for external detector
LOOP1
J11
Connector for encoder
J13
Terminal block for external detector
LOOP2
J16
Terminal block for external flashing light
J18
Terminal block for the arm lights
J20
Terminal block for outputs
J21
Connector for integrated flashing light
J23
Connector for motor
F1
Board protection fuse (F1 = T5A UL approved)
DISPLAY
Programming display
DL1
BUS 2easy ACTIVE LED
BOARD:
DL2
BUS 2easy “BUS MON“ diagnostic LED
DL3
“RADIO1” (OMNIDEC) LED
DL4
“RADIO2” (OMNIDEC) LED
DL5
Error / alarm LED
DL8
EMER
status LED
DL9
STOP
/
FSW-CL
status LED
DL10
CLOSE
status LED
DL11
OPEN
status LED
DL12
LOOP1
status LED
DL13
LOOP2
status LED