12
13
14
15
746 E R
16
732099 - Rev.D
19
H = 20
7
Tr
ansla
tion of the original instruc
tions
ENGLISH
5.2 INSTALLING THE GEARMOTOR
RISKS
PERSONAL PROTECTIVE EQUIPMENT
F
Carry out the work with the power supply disconnected.
1. Make sure that the concrete of the plinth has set completely, then
adjust all the support nuts to the height
H
indicated (
12
).
2. Place the washers on the nuts.
3. Remove the cover from the gearmotor. Position the gearmotor in
correspondence with the 4 fasteners (
13
).
-
Pass the electric cables through the hole on the base and as far
as the board.
!
Be careful not to damage the electrical cable tubes.
4. Make sure that the gearmotor is level. Position the washers and
nuts (
14
).
-
Do not tighten the nuts so that the height can be adjusted when
the rack is being installed.
OPEN THE VENT HOLE
Open the vent hole by removing the breather screw and wash-
er (
15
).
A few drops of oil may leak out after the vent hole has been opened, even
due to the initial movements.
Keep the screw and washer as they will have to be reinstalled if the gearmotor
has to be removed and subsequently transported.
keep the screw and
washer