4.2 Terminal board - Power supply (fig. 2)

 

POWER SUPPLY (terminals PE-N-L): 

 

PE :

 Earth connection

 

N  : 

Power supply  ( Neutral )

 

L  : 

Power supply  ( Line )

NB.:

 For correct operation, the board must be connected to the 

earth  conductor  in  the  system.  Install  an  adequate  differential 

thermal breaker upstream of the system

  MOTOR - (terminals 7-8-9):

 Motor connection.

 

Operators for sliding gates: 

refer to paragraph 4.6 for instructions 

on correct connection of the equipment to the interface 
board on the operator.

 

Operator 5:

 refer to paragraph 4.7 for instructions on correct 

connection of the equipment to the interface board on the 

operator.

 

LAMP - (terminals 0-)

: Flashing lamp output 230Vac  

 

 

   max 60W. 

 

Consult the relevant tables for a detailed description of 

operation in the different logics

OPEN  A  -  “Total  Opening”  command  (terminal  1):

  any  pulse 

generator  (push-button,  detector,  etc.)  which,  by 

closing a contact, commands total opening and/or 

closing of the gate leaf.

 

 

To install several total opening pulse generators, connect 

the N.O. contacts in parallel (fig. 14).

OPEN  B  -  “Partial  opening”  or  “Closing”  command  (terminal 

2):

 any pulse generator (push-button, detector, etc.)  

which, by closing a contact, commands partial opening 

and/or closing of the gate leaf. In the 

B, C 

and

 B/C

 

logics, it always commands gate closure.

 

 

To  install  several  partial  opening  pulse  generators, 

connect the N.O. contacts in parallel (fig.14).

FSW OP - Opening safety devices contact (terminal 3):

 The purpose of 

the opening safety devices is to protect the leaf movement  

area during opening. During opening, in the 

A-AP-S-

E-EP

 logics the safety devices reverse the movement  

of  the  gate,  or  stop  and  restart  the  movement  

when it is released (see advanced  programming in 

Chpt. 5.2). During the opening cycle in logicsthe 

B, C

 

and 

B/C

, they interrupt movement. They never operate 

during the closing cycle.

 

If the 

Opening safety devices 

are engaged when the 

gate is closed, they prevent the opening movement.

 

To install several safety devices, connect the N.C. con-

tacts in series (fig.4).

 

NB.: If no opening safety devices are connected, jumper 

connect inputs FSW OP and -TX FSW

 (fig. 5).

FSW CL - Closing safety devices contact (terminal 4):

 The purpose  

of  the  closing  safety  devices  is  to  protect  the  gate 

movement area during closing. During closing, in the 

A-AP-S-E-EP

  logics,  the  safety  devices  reverse  the  

movement  of  the  gate,  or  stop  and  reverse  the  

movement  when  it  is  released  (see  advanced  

programming  in  Chpt.  5.2).  During  the  closing  cycle 

in logics 

B, C

 and 

B/C

, they interrupt movement. They 

never operate during the opening cycle. If the 

Closing 

safety devices

 are engaged when the gate is open, 

they prevent the closing movement.

 

To install several safety devices, connect the N.C. contacts  

in series (fig.4).

 

NB.: If no closing safety devices are connected, jumper 

connect terminals FSW CL and -TX FSW

 (fig. 5).

STOP

 

-   STOP  contact  (terminal  5):

  any  device  (e.g.  a  

push-button) which, by opening a contact, stops gate 

movement.

 

To  install  several  STOP  devices,  connect  the  N.C.  

contacts in series (fig. 4).  

 

 

NB.:

 If STOP devices are not connected, jumper connect 

the 

STOP 

and - terminals.

SAFE -   EDGE safety device contact (terminal 6):

 The purpose of 

the "edge" safety device is to protect the leaf movement 

area during opening/closing.  In all logics, during opening 

and closing, the safety device reverses gate  movement 

for 2 seconds. If the safety devices operate again during 

the 2-seconds reversing time, it stops movement (STOP) 

without any reversing.

 

If the 

Edge safety device

 is engaged while the gate is 

closed or open, it  prevents  movement.

 

To  install  several  safety  devices,  connect  the  N.C. 

contacts in series (fig.4).

 

NB.: If edge safety devices are not connected, jumper 

connect the SAFE and - inputs

 (fig. 5).

FC  /  FC-  Opening  and  closing  limit-switch  contacts  

(terminals  7  and  8):

  The  purpose  of  the  opening 

and  closing  limit-switches  is  to  establish  the  reference 
point  for  the  stop,  or  for  start  of  deceleration  (pre-  and  
post-limitswitch),  or  for  operator  braking  (see  advanced 
programming  in  Chpt  5.2).  The  limit-switch  device  must 
have an NC contact for connection between the input 
(FC1  or  FC2)  and  the  equipment's  terminal  (see  Fig.2). 

 

OPERATORS FOR SLIDING GATES:

 consult paragraph 4.6 

for correct connection of limit-switches and motor. 

  

OPERATOR  5:

  consult  paragraph  4.7  for  correct  

connection of limit-switches and motor.  

  ENCODER  -  Contacts  of  motor  rotation  control  sensor  

(terminal 9):

 This input is designed for connection of the 

Encoder  sensor. The presence of the encoder is signalled 
- when the gearmotor is running - by the flashing of the 
"ENC" LED on the board. If the encoder is used, the  
equipment  knows the exact gate position during the entire 
movement, and also controls other functions with greater 
precision, such as partial opening and decelerations (see 
advanced programming in Chpt 5.2.). The encoder also 
operates as an anti-crushing device: if the gate strikes an 
obstacle during opening or closing, the encoder reverses  
gate  leaf  movement  for  2  seconds.    If  the  encoder  
operates  again  during  the  2-second  reversing  time, 
it  STOPS  movement  without  performing  any  reversing. 

Note:  in  operators  for  industrial  sectional  doors,  the  
anti-crushing  function  is  not  active  during  closing, 
because the operator acts on the rope shaft and not 
directly on the door.

 – 

Negative for power supply to accessories (terminals 

10, 11 and 12)

 + 

24  Vdc  -  Positive  for  power  supply  to  accessories  

(terminals 13 and 14) 

 

Important: 

Accessories max. load is 500 mA. To calculate 

absorption  values,  refer  to  the  instructions  for  individual 
accessories.

TX  -FSW  -  Negative  for  power  supply  to  photocell  transmitters 

(terminal 5)

 

If  you  use  this  terminal  for  connecting  the  negative  for 

supplying power to the photocell transmitters, you may, if 

necessary, also use the FAIL SAFE function (see advanced  

programming in Chpt. 5.2).

 

If this function is enabled, the equipment checks operation 

of the photocells before every opening or closing cycle.

4.3 J6 Terminal board - Motors and flashing lamp (fig. 2)

4.4  J1 Terminal board  - Accessories (fig. 2)

Содержание 578D

Страница 1: ...4 4 J1 TERMINAL BOARD ACCESSORIES FIG 2 6 4 5 CONNECTOR J2 RAPID CONNECTION TO MINIDEC DECODER AND RP 7 4 6 CONNECTION OF OPERATOR 844 7 4 7 CONNECTION OF OPERATOR 541 7 4 8 CONNECTION OF OPERATORS W...

Страница 2: ...an adequate level of safety the Standards mentioned above must be observed in addition to national legal regulations 11 Before attempting any job on the system cut out electrical power 12 The mains po...

Страница 3: ...ON Power supply V 6 10 230 Absorbed power W 10 Motor max load W 1000 Accessories max load A 0 5 Operating ambient temperature 20 C 55 C Protection fuses 2 see fig 1 Function logics Automatic Stepped a...

Страница 4: ...sing movements They cause immediate reversal of motion and stopping after two seconds Encoder itistrippedifthereisanobstacleduringgateopening and closing movements It causes immediate reversal of moti...

Страница 5: ...photocells and a pair of opening closing photocells Connection of a pair of closing photocells a pair of opening photocells and a pair of opening closing photocells Connection of a pair of opening pho...

Страница 6: ...contact stops gate movement To install several STOP devices connect the N C contacts in series fig 4 NB IfSTOPdevicesarenotconnected jumperconnect the STOP and terminals SAFE EDGEsafetydevicecontact...

Страница 7: ...h respectto theconnectionbetweentheSTOPinputof578D and the SAFETY of the 541 INTERFACE Refer to paragraph 6 3 for instructions on putting into operation To make connections between the 578D equipment...

Страница 8: ...FC1 FC2 2 1 FC1 FC2 ENGLISH Fig 21 Fig 19 Fig 20...

Страница 9: ...Disabled FINAL BRAKING When the gate engages the opening or closing limit switch a braking stroke can be selected to ensure the leaf is stopped immediately If decelerations are selected braking starts...

Страница 10: ...or they reverse it immediately Y Reverse immediately to closing no Restart movement on release ENCODER Iftheencoderisused youmayselectitspresence If the encoder is present and enabled decelerations a...

Страница 11: ...nd activated Command inactive OP B Command activated Command inactive FC1 Limit switch free Limit switch engaged FC2 Limit switch free Limit switch engaged FW OP Safety devices disengaged Safety devic...

Страница 12: ...crushing system ANTI CRUSHING SAFETY DEVICE DURING CLOSING although it has an Encoder sensor the 541 operator cannot intrinsically guarantee this safety device because it is not fitted directly on th...

Страница 13: ...f with Closing Safety devices engaged opens at the 2nd pulse 3 No effect OPEN disabled No effect No effect OPEN disabled Tab 3 b Logic S PULSES GATE STATUS OPEN A OPEN B STOP OPENING SAFETY DEVICES CL...

Страница 14: ...ETY DEVICES OP CL SAFETY DEVICE EDGE SAFETY DEVICE CLOSED Opens the leaf No effect No effect OPEN A disabled No effect No effect OPEN A disabled OPEN No effect Closes the leaf No effect OPEN B disable...

Отзывы: