manualshive.com logo in svg
background image

ENGLISH

Logic  "EP"

PULSES

G

A

TE ST

A

TUS

OPEN-

A

OPEN-B

STOP

OPENING SAFETY DEVICES

CL

OSING SAFETY DEVICES

OP/CL SAFETY DEVICE

EDGE SAFETY DEVICE

CL

OSED

Opens

 the

 leaf

Opens

 leaf

 for

 the

 partial

 

opening

 time

No

 effect

 

(OPEN

 disabled)

No

 effect

No

 effect

  

(OPEN

 disabled)

OPEN

Re-closes

 the

 leaf

 immediately

 (3)

Stops

  

operation

No

 effect

  

(if

 on

 part.opng.

 OPEN

 A

 disabled)

No

 effect

  

(OPEN

 disabled)

 (3)

 

No

 effect

  

(OPEN

 disabled)

CL

OSING

Stops

 operation

No

 effect

  

(saves

 OPEN)

See

 paragraph

 5.2

 

Locks

 and,

 on

 release,

 

reverses

 to

 open

Reverses

 to

 open

 for

 2"

 (2)

OPENING

Stops

 operation

 (3)

See

 paragraph

 5.2

No

 effect

Locks

 and,

 on

 release,

  

continues

 opening

Reverses

 to

 close

 for

 2"

 (2)

LOCKED

Restarts

 movement

 in

 reverse

 dir

ection

(always

 closes

 after

 a

 Stop)

 (3)

No

 effect

 

(OPEN

 disabled)

No

 effect

 

(if

 it

 must

 open

, it

 disables

 OPEN)

No

 effect

 

(if

 it

 must

 close,

 it

 disables

 OPEN)

No

 effect

  

(OPEN

 disabled)

Tab. 3/e

Logic  "C"

CONTROLS AL

W

A

YS HELD DOWN

PULSES

G

A

TE ST

A

TUS

OPEN-

A (opening)

OPEN-B (closing)

STOP

OPENING SAFETY DEVICES

CL

OSING SAFETY DEVICES

OP/CL SAFETY DEVICE

EDGE SAFETY DEVICE

CL

OSED

Opens

 the

 leaf

No

 effect

 

(OPEN-

A

 disabled)

No

 effect

 

(OPEN-

A

 disabled)

No

 effect

Stops

 operation

 

(OPEN-

A

 disabled)

OPEN

No

 effect

 

(OPEN-B

 disabled)

Closes

 the

 leaf

No

 effect

 

(OPEN-

A/B

 disabled)

No

 effect

 

(OPEN-

A

 disabled)

No

 effect

 

(OPEN-B

 disabled)

 

No

 effect

 

(OPEN-B

 disabled)

Stops

 operation

 

(OPEN-

A/B

 disabled)

CL

OSING

Stops

 operation

/

Stops

  

operation

No

 effect

Stops

 operation

 

(OPEN-B

 disabled)

Stops

 operation

 

(OPEN-

A/B

 disabled)

Reverses

 to

 open

 for

 2"

 (2)

LOCKED

/

Stops

 operation

Stops

 operation

 

(OPEN-

A

 disabled)

No

 effect

Stops

 operation

 

(OPEN-

A/B

 disabled)

Reverses

 to

 close

 for

 2"

 (2)

Tab. 3/f

Logic  "B"

PULSES

G

A

TE ST

A

TUS

OPEN-

A (opening)

OPEN-B (closing)

STOP

OPENING SAFETY DEVICES

CL

OSING SAFETY DEVICES

OP/CL SAFETY DEVICE

EDGE SAFETY DEVICE

CL

OSED

Opens

 the

 leaf

No

 effect

 

No

 effect

 

(OPEN-

A

 disabled)

No

 effect

No

 effect

 

(OPEN-

A

 disabled)

OPEN

No

 effect

Closes

 the

 leaf

No

 effect

(OPEN-B

 disabled)

 No

 effect

No

 effect

 

(OPEN-B

 disabled)

 

No

 effect

 

(OPEN-B

 disabled)

No

 effect

(OPEN-

A/B

 disabled)

CL

OSING

Reverses

 to

 open

No

 effect

Stops

  

operation

No

 effect

 

(saves

 OPEN-

A)

Stops

 operation

 

(OPEN-B

 disabled)

Stops

 operation

 

(OPEN-

A/B

 disabled)

Reverses

 to

 open

 for

 2"

 (2)

OPENING

No

 effect

 

No

 effect

Stops

 operation

 

(OPEN-

A

 disabled)

No

 effect

 

Stops

 operation

 

(OPEN-

A/B

 disabled)

Reverses

 to

 close

 for

 2"

 (2)

LOCKED

Opens

 the

 leaf

Closes

 the

 leaf

No

 effect

 

(OPEN-

A/B

 disabled)

No

 effect

 

(OPEN-

A

 disabled)

No

 effect

 

(OPEN-B

 disabled)

No

 effect

(OPEN-

A/B

 disabled)

Tab. 3/g

Logic  "B/C"

OPENING P

ULSE/CL

OSING HOLD TO RUN CONTROLS 

PULSES

G

A

TE ST

A

TUS

OPEN-

A (opening)

OPEN-B (closing)

STOP

OPENING SAFETY DEVICES

CL

OSING SAFETY DEVICES

OP/CL SAFETY DEVICE

EDGE SAFETY DEVICE

CL

OSED

Opens

 the

 leaf

No

 effect

 

No

 effect

 

(OPEN

 A

 disabled)

 No

 effect

No

 effect

 

(OPEN

 A

 disabled)

OPEN

No

 effect

Closes

 the

 leaf

No

 effect

 

(OPEN

 B

 disabled)

 No

 effect

No

 effect

 

(OPEN

 B

 disabled)

 

No

 effect

 

(OPEN

 B

 disabled)

No

 effect

(OPEN-

A/B

 disabled)

CL

OSING

Reverses

 to

 open

No

 effect

 

Stops

operation

No

 effect

 

(saves

 OPEN

 A)

Stops

 operation

 

(OPEN-B

 disabled)

Stops

 operation

 

(OPEN-

A/B

 disabled)

Reverses

 to

 open

 for

 2"

 (2)

OPENING

No

 effect

 

No

 effect

 

Stops

 operation

 

(OPEN-

A

 disabled)

 No

 effect

 

Stops

 operation

 

(OPEN-

A/B

 disabled)

Reverses

 to

 close

 for

 2"

 (2)

LOCKED

Opens

 the

 leaf

Closes

 the

 leaf

No

 effect

 

(OPEN

 A/B

 disabled)

No

 effect

 

(OPEN

 A

 disabled)

No

 effect

 

(OPEN

 B

 disabled)

No

 effect

 

(OPEN

 A/B

 disabled)

Tab. 3/h

(1)

 If

 maintained,

 it

 pr

olongs

 the

 pause

 until

 disabled

 by

 the

 command

 (timer

 function)

 

 

(3)

 During

 the

 partial

 opening

 cycle,

 an

 OPEN

 A

 pulse

 causes

 total

 opening.

 

 

(2)

 If

 a

 new

 pulse

 occurs

 within

 2

 seconds

 after

 reversing,

 it

 immediately

 stops

 operation

.

 

 

NB.:

 Effects

 on

 other

 active

 pulse

 inputs

 in

 brack

ets.

Содержание 578D

Страница 1: ...4 4 J1 TERMINAL BOARD ACCESSORIES FIG 2 6 4 5 CONNECTOR J2 RAPID CONNECTION TO MINIDEC DECODER AND RP 7 4 6 CONNECTION OF OPERATOR 844 7 4 7 CONNECTION OF OPERATOR 541 7 4 8 CONNECTION OF OPERATORS W...

Страница 2: ...an adequate level of safety the Standards mentioned above must be observed in addition to national legal regulations 11 Before attempting any job on the system cut out electrical power 12 The mains po...

Страница 3: ...ON Power supply V 6 10 230 Absorbed power W 10 Motor max load W 1000 Accessories max load A 0 5 Operating ambient temperature 20 C 55 C Protection fuses 2 see fig 1 Function logics Automatic Stepped a...

Страница 4: ...sing movements They cause immediate reversal of motion and stopping after two seconds Encoder itistrippedifthereisanobstacleduringgateopening and closing movements It causes immediate reversal of moti...

Страница 5: ...photocells and a pair of opening closing photocells Connection of a pair of closing photocells a pair of opening photocells and a pair of opening closing photocells Connection of a pair of opening pho...

Страница 6: ...contact stops gate movement To install several STOP devices connect the N C contacts in series fig 4 NB IfSTOPdevicesarenotconnected jumperconnect the STOP and terminals SAFE EDGEsafetydevicecontact...

Страница 7: ...h respectto theconnectionbetweentheSTOPinputof578D and the SAFETY of the 541 INTERFACE Refer to paragraph 6 3 for instructions on putting into operation To make connections between the 578D equipment...

Страница 8: ...FC1 FC2 2 1 FC1 FC2 ENGLISH Fig 21 Fig 19 Fig 20...

Страница 9: ...Disabled FINAL BRAKING When the gate engages the opening or closing limit switch a braking stroke can be selected to ensure the leaf is stopped immediately If decelerations are selected braking starts...

Страница 10: ...or they reverse it immediately Y Reverse immediately to closing no Restart movement on release ENCODER Iftheencoderisused youmayselectitspresence If the encoder is present and enabled decelerations a...

Страница 11: ...nd activated Command inactive OP B Command activated Command inactive FC1 Limit switch free Limit switch engaged FC2 Limit switch free Limit switch engaged FW OP Safety devices disengaged Safety devic...

Страница 12: ...crushing system ANTI CRUSHING SAFETY DEVICE DURING CLOSING although it has an Encoder sensor the 541 operator cannot intrinsically guarantee this safety device because it is not fitted directly on th...

Страница 13: ...f with Closing Safety devices engaged opens at the 2nd pulse 3 No effect OPEN disabled No effect No effect OPEN disabled Tab 3 b Logic S PULSES GATE STATUS OPEN A OPEN B STOP OPENING SAFETY DEVICES CL...

Страница 14: ...ETY DEVICES OP CL SAFETY DEVICE EDGE SAFETY DEVICE CLOSED Opens the leaf No effect No effect OPEN A disabled No effect No effect OPEN A disabled OPEN No effect Closes the leaf No effect OPEN B disable...

Отзывы: