5 PROGRAMMING

F

F

+

+

BASIC PROGRAMMING

Display             Function 

 

 Default

FUNCTION LOGICS  (see table of logics):

 

A

= Automatic

 

AP

= "Stepped" automatic

 

S

= "Safety" Automatic

 

E

= Semi-automatic

 

EP

= "Stepped" Semi-automatic

 

C

= Dead-man

 

b

= "B" Semi-automatic

 

bC

= Mixed Log. (B opening / C closing)

PAUSE TIME:

This has effect only if the automatic logic was 
selected.  Adjustable  from 

0

  to 

59 

sec.  in 

one-second steps.
Subsequently, display changes to minutes and 
tens of seconds (separated by a point) and time is 
adjusted in 10-second steps, up to the maximum 
value of 

4,1

  minutes.

E.g. if the display shows 

2.5

, pause time is 2 

min. and 50 sec.

To access ADVANCED PROGRAMMING, press key 

F

 and, as 

you hold it down, press key 

+

:

•if you release key 

+

 , the display indicates the name of the 

first function.

•if you release key 

F

 too, the display shows the value of the 

function that can be modified with keys 

+

 and 

-

.

•if you press key 

F

 (and hold it down), the display shows the 

name of the next function, and if you release it, the value that 

can be modified with keys 

+

 and 

-

 is shown.

•when you reach the last function, press 

F

 to exit the program, 

and the display resumes showing the gate status.

The  following  table  shows  the  sequence  of  functions 

accessible in ADVANCED PROGRAMMING:

To program operation of the automated system, you have 

to access the "PROGRAMMING" mode. 

Programming is split into two parts: BASIC and ADVANCED. 

ADVANCED PROGRAMMING

Display             Function 

 

  Default

MAXIMUM TORQUE AT INITIAL THRUST:

The motor operate at maximum torque (ignoring 
the torque setting) at start of movement. Useful 
for heavy leaves.
 

Y

= Active

 

no

= Disabled

FINAL BRAKING:

When the gate engages the opening or closing 
limit-switch, a braking stroke can be selected 
to  ensure  the  leaf  is  stopped  immediately.  If 
decelerations are selected, braking starts when 
they finish.
At 

00

  value, braking is disabled. 

  Time  can  be  adjusted  from 

01

    to 

20

  in 

0.01-second steps.
        

00 

=  Braking disabled

from 

01

 to 

20

 =  Timed braking

To access BASIC PROGRAMMING, press  key 

F

:

•if you press it (and hold it down), the display shows the name 

of the first function.

•if  you  release  the  key,  the  display  shows  the  value  of  the 

function that can be modified with keys 

+

 and 

-

.

•if you press 

F

 again (and hold it down), the display shows the 

name of the next function, etc.

•when you reach the last function, press 

F

 to exit the program, 

and the display resumes showing the gate status.

The  following  table  shows  the  sequence  of  functions 

accessible in BASIC PROGRAMMING:

FORCE:

Adjusts Motor thrust.
 

0 1

= minimum force

 

50 

= maximum force

STATUS OF AUTOMATED SYSTEM:

Exit from programming, save data, and return 
to gate status viewing
  

00

= Closed

  

01

= Now opening

  

02

= At "STOP"

  

03

= Open

  

04

= Pause

  

05

= "FAIL SAFE" tripped

  

06

= Now closing

  

07

= Now reversing

  

08

= Photocells tripped

OPENING DIRECTION:

Indicates the gate opening movement and makes it 
possible not to change the motor and limit-switches  
connections on the terminal board.
 

-3

= Standard opening movement

 

E-

= Reverse opening movement

5.1 BASIC PROGRAMMING

5.2 ADVANCED PROGRAMMING

FAIL SAFE:

If this function is activated, it enables a function 
test of the photocells before any gate movement.  
If the test fails (photocells not serviceable signalled 
by value 

05

 on the display), the gate does not 

start moving.
 

Y

= Active

 

no

= Disabled

PRE-FLASHING (5 s.):

Activates the flashing lamp for 5 seconds before 
start of movement.
 

no 

= Disabled

 

oP 

= only before opening

  

CL 

= only before closing

  

OC 

= before every movement

Содержание 578D

Страница 1: ...4 4 J1 TERMINAL BOARD ACCESSORIES FIG 2 6 4 5 CONNECTOR J2 RAPID CONNECTION TO MINIDEC DECODER AND RP 7 4 6 CONNECTION OF OPERATOR 844 7 4 7 CONNECTION OF OPERATOR 541 7 4 8 CONNECTION OF OPERATORS W...

Страница 2: ...an adequate level of safety the Standards mentioned above must be observed in addition to national legal regulations 11 Before attempting any job on the system cut out electrical power 12 The mains po...

Страница 3: ...ON Power supply V 6 10 230 Absorbed power W 10 Motor max load W 1000 Accessories max load A 0 5 Operating ambient temperature 20 C 55 C Protection fuses 2 see fig 1 Function logics Automatic Stepped a...

Страница 4: ...sing movements They cause immediate reversal of motion and stopping after two seconds Encoder itistrippedifthereisanobstacleduringgateopening and closing movements It causes immediate reversal of moti...

Страница 5: ...photocells and a pair of opening closing photocells Connection of a pair of closing photocells a pair of opening photocells and a pair of opening closing photocells Connection of a pair of opening pho...

Страница 6: ...contact stops gate movement To install several STOP devices connect the N C contacts in series fig 4 NB IfSTOPdevicesarenotconnected jumperconnect the STOP and terminals SAFE EDGEsafetydevicecontact...

Страница 7: ...h respectto theconnectionbetweentheSTOPinputof578D and the SAFETY of the 541 INTERFACE Refer to paragraph 6 3 for instructions on putting into operation To make connections between the 578D equipment...

Страница 8: ...FC1 FC2 2 1 FC1 FC2 ENGLISH Fig 21 Fig 19 Fig 20...

Страница 9: ...Disabled FINAL BRAKING When the gate engages the opening or closing limit switch a braking stroke can be selected to ensure the leaf is stopped immediately If decelerations are selected braking starts...

Страница 10: ...or they reverse it immediately Y Reverse immediately to closing no Restart movement on release ENCODER Iftheencoderisused youmayselectitspresence If the encoder is present and enabled decelerations a...

Страница 11: ...nd activated Command inactive OP B Command activated Command inactive FC1 Limit switch free Limit switch engaged FC2 Limit switch free Limit switch engaged FW OP Safety devices disengaged Safety devic...

Страница 12: ...crushing system ANTI CRUSHING SAFETY DEVICE DURING CLOSING although it has an Encoder sensor the 541 operator cannot intrinsically guarantee this safety device because it is not fitted directly on th...

Страница 13: ...f with Closing Safety devices engaged opens at the 2nd pulse 3 No effect OPEN disabled No effect No effect OPEN disabled Tab 3 b Logic S PULSES GATE STATUS OPEN A OPEN B STOP OPENING SAFETY DEVICES CL...

Страница 14: ...ETY DEVICES OP CL SAFETY DEVICE EDGE SAFETY DEVICE CLOSED Opens the leaf No effect No effect OPEN A disabled No effect No effect OPEN A disabled OPEN No effect Closes the leaf No effect OPEN B disable...

Отзывы: