Important Safety Information

Both the installer and the owner and/or operator of 
this system need to read and understand this 
installation manual and the safety instructions 
supplied with other components of the gate system. 
This information should be retained by the owner 
and/or operator of the gate. 

WARNING!

 To reduce the risk of injury or death 

1. 

READ  AND  FOLLOW  ALL 
INSTRUCTIONS.

 

2. 

Never let children operate or play with 
gate controls. Keep the remote control 
away from children. 

3. 

Always keep people and objects away 
from the gate. NO ONE SHOULD 
CROSS THE PATH OF THE 
MOVING GATE. 

4. 

Test the gate operator monthly. The 
gate MUST reverse on contact with a 
rigid object or stop when an object 
activates the non-contact sensors. After 
adjusting the force or the limit of travel, 
retest the gate operator. Failure to 
adjust and retest the gate operator 
properly can increase the risk of injury 
or death. 

5. 

Use the emergency release only when 
the gate is not moving. 

6. 

KEEP GATES PROPERLY 
MAINTAINED. Read the owner’s 
manual. Have a qualified service person 
make repairs to gate hardware. 

7. 

The entrance is for vehicles only. 
Pedestrians must use separate entrance. 

8. SAVE THESE INSTRUCTIONS. 

There are three kinds of safety issues involved with an 
automatic gate operator: issues arising from the design 
of the gate, from the installation of the gate and the 
operator, and from the use of the gate operator. The 
following information is designed to help you be sure 
your gate and its operator are well-designed, installed 
correctly, and used safely.  

Gate Design 

1.  A gate is a potential traffic hazard, so it is im-

portant that you locate the gate far enough away 
from the road to eliminate the potential of traffic 
getting backed up. This distance is affected by the 
size of the gate, how often it is used, and how fast 
the gate operates. 

2.  The operator you choose to install on your gate 

must be designed for the type and size of your gate 
and for the frequency with which you use the 
operator. 

3.  Your gate must be properly installed and must 

work freely in both directions before the automatic 
operator is installed. 

4.  An automatic operator should be installed on the 

inside of the property/fence line. Do not install the 
operator on the public side of the property/fence 
line. 

5.  Pedestrians should not use a vehicular gate system. 

Prevent such inappropriate use by installing 
separate gates for pedestrians. 

6.  Exposed, reachable pinch points on a gate are 

potentially hazardous and must be eliminated or 
guarded. 

7.  Outward swinging gates with automatic operators 

should not open into a public area. 

8.  The operating controls for an automatic gate must 

be secured to prevent the unauthorized use of those 
controls. 

9.  The controls for an automatic gate should be 

located far enough from the gate so that a user 
cannot accidentally touch the gate when operating 
the controls. 

10.  An automatic gate operator should not be installed 

on a gate if people can reach or extend their arms or 
legs through the gate. Such gates should be guarded 
or screened to prevent such access. 

Installation 

1.  If you have any question about the safety of the 

gate operating system, do not install this operator. 
Consult the operator manufacturer. 

2.  The condition of the gate structure itself directly 

affects the reliability and safety of the gate 
operator. 

3.  Only qualified personnel should install this 

equipment. Failure to meet this requirement could 

Содержание 412 Compact

Страница 1: ...ate Leaf 10 Attach the Rear Mounting Bracket 10 Attach the Operator to the Rear Mounting Bracket 12 Attach the Operator to the Front Mounting Bracket 12 Attach the Front Mounting Bracket to the Gate L...

Страница 2: ...ortant that you locate the gate far enough away from the road to eliminate the potential of traffic getting backed up This distance is affected by the size of the gate how often it is used and how fas...

Страница 3: ...al equipment observe some fundamental rules Do not touch the equipment with damp or humid hands or feet Do not install or operate the equipment with bare feet Do not allow small children or incapable...

Страница 4: ...may affect duty cycle 4 The 90 deg opening time for a gate with the 412 Operator is a maximum of about 46 sec Note that both the mounting dimensions and the torque adjustment help to determine the pr...

Страница 5: ...is marked SX and one is marked DX Be sure to install each on the proper gate leaf see Figure 2 2 Protective covers for the worm screw housing of the operator 1 Package of mounting hardware 2 Rear mou...

Страница 6: ...on the single phase bidirectional motor shuts off automatically if its operating temperature reaches 284 deg F 140 deg C Also for the protection and proper operation of the 412 Operator each gate leaf...

Страница 7: ...e 450 MPS control panel are briefly described below You can find a complete description of each logic in the tables on the following pages A automatic The gate opens on command and automatically close...

Страница 8: ...them after pause time Opens single leaf connected to Motor 1 and closes it after pause time No effect No effect No effect Off Opening Closes both leaves immediately Closes the leaf immediately Stops S...

Страница 9: ...1 No effect opening is inhibited No effect opening is inhibited No effect opening is inhibited Off Opening Stops Stops Stops Stops gate closes when reversing device no longer triggered No effect On O...

Страница 10: ...Installing the operator consists of the following steps Establishing the orientation of each gate leaf and its operator Attaching the rear mounting bracket Attaching the operator to the rear mounting...

Страница 11: ...acket see Figure 6 The recessed liner should be constructed of 3 16 or 1 4 in steel with a minimum interior height of 11 13 16 in 30 cm so as to allow you to meet the required dimensions shown in Figu...

Страница 12: ...gate installation Inward swinging Lengthen the worm screw completely and push the cylinder in one inch Outward swinging Shorten the worm screw completely and then pull the cylinder out one inch With t...

Страница 13: ...unting plate to the center of the front mounting hole on the operator Figure 9 Secure the operator to the front mounting bracket with the short pin and 2 snap rings dimensions are incorrect see Figure...

Страница 14: ...WARNING The voltage of the main power must match the required voltage of the 412 Operator and the 450 MPS control panel Wire the main power supply to control panel terminals in block J1 see Figures 13...

Страница 15: ...the control panel enclosure For the purposes of installation you need to connect at least one normally open N O activating device for your operator s If you have a two leaf gate design connect the ac...

Страница 16: ...Listed cord grip Junction box Op 1 Op 2 1 2 3 4 5 6 7 8 OP COM CL CL COM OP Lamp Motor 1 Motor 2 J1 J2 High voltage terminal strip 450 MPS Control Panel U L Listed Control Panel Enclosure Cord grip or...

Страница 17: ...tially dangerous Do not place yourself within the path of the moving gate during your test Disengage the operator s with the Manual Release key and open the gate by hand about halfway Next engage the...

Страница 18: ...on terminal block J3 requires a fail safe connection for the photocells Connect the photocells to terminals 20 and 21 in the FSWTX grouping Activating Devices and Radio Receiver The acti vating device...

Страница 19: ...button you must install a circuit between these terminals for the control panel to work The LED Indicators The five light emitting diodes LEDs on the control panel can be used to check for the proper...

Страница 20: ...ol Panel has 5 DIP switches and 4 potentiometers that control a wide range of functions Set DIP Switches Switches 1 2 and 3 Operating Logic The 450 MPS Control Panel offers six operating modes A S E E...

Страница 21: ...5 sec Note You cannot adjust this opening delay of the operator connected to Motor 2 However you can avoid the opening delay and closing delay by connecting both operators and their capacitors to Mot...

Страница 22: ...k J3 Check the LED DL1 for a two leaf gate or DL2 for a one leaf gate One of them should turn on when you signal the gate to open or to close If neither one illuminates then check the wiring for the a...

Страница 23: ...negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or otherwise exceeding...