Number of
power supplies
installed
Maximum
system heat
(BTU/hr)
Typical
system heat
(BTU/hr)
Maximum
system power
draw (W)
Typical
system power
draw (W)
Blade
quantity
and type
2
2355
1710
690
500
2 x B2250
2
3260
2390
955
700
3 x B2250
2
4250
3075
1245
900
4 x B2250
DC power requirements
When working with a DC-powered VIPRION
®
2400 platform, it is important to understand the DC power
options and requirements.
The platform supports up to two hot swappable DC power supplies. One power supply powers a chassis
that contains zero to four blades, with no redundancy. Two power supplies power a chassis with any blade
configuration, with full redundancy.
DC platform power consumption
The actual amount of power draw from the DC power source depends on the type and number of blades,
and the redundancy configuration. This table shows several possible configurations, and the typical and
maximum power draw.
Number of
power supplies
installed
Maximum
system heat
(BTU/hr)
Typical
system heat
(BTU/hr)
Maximum
system power
draw (W)
Typical
system power
draw (W)
Blade
quantity
and type
1 or 2
< 340
< 340
< 100
< 100
Chassis only
1
1145
820
335
240
1 x B2100
1
1895
1420
555
415
2 x B2100
1
2835
2035
830
595
3 x B2100
1
3705
2645
1085
775
4 x B2100
2
1215
875
355
255
1 x B2100
2
2000
1470
585
430
2 x B2100
2
2820
2065
825
605
3 x B2100
2
3620
2680
1060
785
4 x B2100
1
1145
820
335
240
1 x B2150
1
1895
1420
555
415
2 x B2150
1
2835
2035
830
595
3 x B2150
1
3705
2645
1085
775
4 x B2150
2
1215
875
355
255
1 x B2150
2
2000
1470
585
430
2 x B2150
2
2820
2065
825
605
3 x B2150
64
Platform Specifications
Содержание VIPRION 2400
Страница 1: ...Platform Guide VIPRION 2400 MAN 0344 05 ...
Страница 2: ......
Страница 6: ...6 Table of Contents ...
Страница 44: ......
Страница 58: ...Figure 16 Airflow in the VIPRION 2400 platform 58 Environmental Guidelines ...
Страница 68: ......
Страница 70: ...70 China RoHS Requirements ...
Страница 71: ...71 Platform Guide VIPRION 2400 ...
Страница 72: ......
Страница 78: ......
Страница 82: ......