OPERATING PROCEDURES
Read all of this manual to become thoroughly familiar with this vehicle. Pay particular attention to all Notices, Cautions, Warnings, and Dangers.
Page 30
Owner’s Guide
RED FLASH = fault code
LED Fault Codes:
RED FLASH: Light turns on briefly, but does not flash after that - check for valid AC voltage.
ONE RED FLASH: One flash, a pause and then again one flash and a pause - Charge Enable Fault: poor contact in
the DC connector or dirty contacts or Battery Temperature Fault: battery temperature is greater than 122° F (50° C)
or less than 14° F (-10° C).
TWO RED FLASHES: Two flashes, a pause and then again two flashes and a pause - Battery Voltage Fault: Battery
pack is less than 48.0 Volts or more than 67.2 Volts. Battery pack is too discharged or over charged for the charger
to work.
THREE RED FLASHES: Three flashes, a pause and then again three flashes and a pause - Battery Charge Time-
out: Charge time exceeded 24 hours. This may indicate a problem with the battery pack or that the charger output
current was severely reduced due to high ambient temperatures.
FOUR RED FLASHES: Four flashes, a pause and then again four flashes and a pause - Battery Fault: Charge time
exceeded. This indicates a problem with the battery pack voltage not reaching the required nominal level within the
maximum time allowed.
SIX RED FLASHES: Six flashes, a pause and then again six flashes and a pause - Charger Fault: An internal fault
has been detected. If this fault is displayed again after unplugging the charger’s DC power cord and plugging it back
in, the charger must be taken to a qualified service center.
To prevent a physical hazard that could result in an electrical shock or electrocution, be sure
that the charger plug is not damaged and is inserted into a grounded receptacle.
The power (AC) cord is equipped with a grounded plug. Do not attempt to pull out, cut or bend
the ground post.
The charging (DC) cord is equipped with a polarized connector that fits into a matching receptacle on the vehicle. The
receptacle is located on the driver side of the vehicle just below the seat bottom.
Fig. 4 Charger Receptacle
Maintenance Instructions
1. For flooded lead-acid batteries, regularly check the water levels of each battery cell after charging and add distilled water
as required to the level specified by the battery manufacturer. Follow the safety instructions recommended by the battery
manufacturer.
2. Make sure the charger connections to the battery terminals are tight and clean. Check for any deformations or cracks in
the plastic parts. Check the charger harness for chaffing and rubbing. Inspect all wiring for fraying, loose terminals, chaff-
ing, corrosion or deterioration of the insulation.
Содержание MPT 1000 48V
Страница 1: ...LLl OWNER S GUIDE ISSUED AUGUST 2010 REVISED APRIL 2011 MPT 48V ELECTRIC POWERED VEHICLES 615581 GB...
Страница 73: ...Page 67 Owner s Guide DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY EUROPE ONLY...
Страница 74: ...Page 68 Owner s Guide DECLARATION OF CONFORMITY...
Страница 75: ...Page 69 Owner s Guide DECLARATION OF CONFORMITY...
Страница 76: ...Page 70 Owner s Guide DECLARATION OF CONFORMITY Notes...
Страница 77: ......