red
green
blue
Direct input of RGB values
Apply actual
wall status
After the desired values are entered, all offsets and
brightness values are transferred to the selected
cube(s).
The cubes are then adjusted accordingly to
immediately check the new entries.
reset
adjustment
Deletes all the set but not saved offsets under
led
adjustment
or
cie adjustment
for all cubes. The
offsets that are stored on the cubes are not deleted.
By resetting the values, the fine calibration can be
restarted.
read stored
configuration
Restores the last offsets stored in the cube. Unwanted
or defective settings can be reset in this way.
reset
Resets the changes made under
red/green/blue
.
Opens the window for entering the CIE values.
Fig. 17: Fine adjustment with CIE window
CIE adjustment
Setting the CIE offset either by applying the RGB values, entering
numerical figures or by changing settings in the colour field.
Applies the RGB values to all cubes.
Applies the RGB values only to the cube selected in
cube selection
.
x
y
l
Selects the CIE parameters which should be changed by the
RGB input.
cie x
cie y
l
Display and numerical input of offsets.
62
EC CUBE with LED Projection Engine
the ec-lcontrol softwAre